ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Chemistry  (11,373)
  • Industrial Chemistry
  • 1995-1999  (11,373)
  • 1995  (11,373)
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Astrophysics and space science 224 (1995), S. 81-84 
    ISSN: 1572-946X
    Keywords: Chemistry ; Depletions ; Shocks ; IRAS 05338-0624 ; NGC 1333 IRAS 4
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract High resolution interferometer and single-dish observations of young, deeply embedded stellar systems reveal a complex chemistry in the circumstellar environments of low to intermediate mass stars. Depletions of gas-phase molecules, grain mantle evaporation, and shock interactions actively drive chemical processes in different regions around young stars. We present results for two systems, IRAS 05338-0624 and NGC 1333 IRAS 4, to illustrate the behavior found and to examine the physical processes at work.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Astrophysics and space science 233 (1995), S. 125-137 
    ISSN: 1572-946X
    Keywords: Interstellar Medium ; Dark Clouds ; Chemistry ; Bistability ; C-shock Waves
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract Shock waves perturb the chemical state of the interstellar gas. We consider the effects of C-shocks on the composition of molecular clouds, for a range of values of the pre-shock gas density and magnetic induction. The time required to re-establish equilibrium in the post-shock gas depends on the initial conditions and can become very large. The significance of the two known chemical phases of dark clouds and of bistability is considered in this context.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Astrophysics and space science 233 (1995), S. 161-164 
    ISSN: 1572-946X
    Keywords: Stars ; Chemistry ; Diffusion
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract We have assessed the role of diffusion in determining chemical abundances in molecular interface regions. Chemical models have been developed which include the appropriate diffusion terms and that are appropriate to a narrow diffusion region (∼0.01pc) that may exist at the interface between a dark core and a hot, shocked T-Tauri wind. We have assumed pressure balance throughout and have calculated the chemical abundances as functions of time and position through the interface. The results show that significant enhancements of detectable molecules/transitions are expected (e.g. CO J=6→5, OH and CH). Using a realistic value of the diffusion coefficient a diffusive region of dimension 0.01pc may be established within about 104 years. In general it seems likely that diffusion processes are highly significant on these and smaller lengthscales.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Journal of Chemometrics 9 (1995), S. 197-209 
    ISSN: 0886-9383
    Keywords: proficiency test ; true value ; homogeneity robust statistic ; standard ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Profficiency tests raise two types of problems: (i) the homogeneity of a sample must be carefully checked before using it as a reference material; (ii) it is necessary to define a conventional reference value (RV) in order to rank participants. Since these topics are poorly addressed in the literature, a reference material was specially prepared in order to propose a procedure for verifying homogeneity and to establish whether the algorithms classically used to compute the conventional true value have an influence on the conclusion of the test.The homogeneity of the sample was not perfect and univariate and multivariate techniques were used to demonstrate some analytes can be suspected as heterogeneous. However, this was considered adequate for introducing the sample in a large proficiency test organized between four laboratory associations which regularly perform such tests. Altogether more than 3000 measurements were collected and eight algorithms were applied to compute the RV on 14 analytes. Thus is was possible to demonstrate that some of these algorithms are better adapted than others. It is also obvious that some analytes are better suited to proficiency testing.It can be concluded from this work that some effort towards standardization would be profitable to check homogeneity or to compute the RV, especially since the economic weight of proficiency testing is becoming even more important with the development of certification accreditation.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Journal of Chemometrics 9 (1995) 
    ISSN: 0886-9383
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Journal of Chemometrics 9 (1995), S. 451-457 
    ISSN: 0886-9383
    Keywords: non-linear regression ; optimization ; robust methods ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Several robust regression methods, including a new proposal, are described and their properties discussed. Resistance to various types of outliers and non-normality is demonstrated. The techniques are applied to non-linear regression models from chemical kinetics and calibration. Optimization of the types of objective functions encountered when applying robust regression is considered.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Journal of Chemometrics 9 (1995), S. 471-481 
    ISSN: 0886-9383
    Keywords: batch prediction ; continuum regression ; multivariate calibration ; sequential prediction ; simultaneous prediction ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: In analytical chemistry a single fitted calibration model is used repeatedly to predict the level of the analyte of interest for the specimens comprising the prediction set. Unlike the calibration (or training) set, which is often limited in size, the prediction set can be very large.In the case of multivariate calibration a number of methods such as PLS and PCR are commonly used to construct the calibration model. The set of instrumental measurements and the reference analyte level are available for each specimen in the calibration set. For specimens in the prediction set, only the instrumental measurements are available, since the problem is to predict the analyte level for these specimens. It is not widely recognized that predictions of the analyte levels for individual specimens can be improved by utilizing seemingly unrelated information from the instrumental measurements associated with the other members of the prediction set. In the case of PCR there exists a very straightforward procedure for doing this. A description of the various sources of prediction errors is provided to explain the ability of PCR to utilize this additional information. The use of PCR in this context is illustrated with both a synthetic and a real example.
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
  • 9
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Journal of Chemometrics 9 (1995), S. 21-29 
    ISSN: 0886-9383
    Keywords: Near-infrared absorbance ; Partial least squares ; Principal component regression ; Root-mean-square error of prediction ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The use of principal component regression (PCR) as a multivariate calibration method has been discussed by a number of authors. In most situations principal components are included in the regression model in sequence based on the variances of the components, and the principal components with small variances are rarely used in regression. As pointed out by some authors, a low variance for a component does not necessarily imply that the corresponding component is unimportant, especially when prediction is of primary interest. In this paper we investigate a different version of PCR, correlation principal component regression (CPCR). In CPCR the importance of principal components in terms of predicting the response variable is used as a basis for the inclusion of principal components in the regression model. Two typical examples arising from calibrating near-infrared (NIR) instruments are discussed for the comparison of the two different versions of PCR along with partial least squares (PLS), a commonly used regression approach in NIR analysis. In both examples the three methods show similar optimal prediction ability, but CPCR performs better than standard PCR and PLS in terms of the number of components needed to achieve the optimal prediction ability. Similar results are also seen in other NIR examples.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Journal of Chemometrics 9 (1995), S. i 
    ISSN: 0886-9383
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...