ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • FSEARCHIPCASiterative phasingcryo-EMmodel buildingstructure determinationcryo-electron microscopyX-ray crystallographyphase problem  (1)
  • International Union of Crystallography (IUCr)  (1)
  • American Institute of Physics (AIP)
  • 2015-2019  (1)
  • 2010-2014
  • 2018  (1)
Collection
Keywords
Publisher
  • International Union of Crystallography (IUCr)  (1)
  • American Institute of Physics (AIP)
Years
  • 2015-2019  (1)
  • 2010-2014
Year
  • 2018  (1)
  • 1
    facet.materialart.
    Unknown
    International Union of Crystallography (IUCr)
    In: IUCrJ
    Publication Date: 2018-05-12
    Description: X-ray crystallography and cryo-electron microscopy (cryo-EM) are complementary techniques for structure determination. Crystallography usually reveals more detailed information, while cryo-EM is an extremely useful technique for studying large-sized macromolecules. As the gap between the resolution of crystallography and cryo-EM data narrows, the cryo-EM map of a macromolecule could serve as an initial model to solve the phase problem of crystal diffraction for high-resolution structure determination. FSEARCH is a procedure to utilize the low-resolution molecular shape for crystallographic phasing. The IPCAS (Iterative Protein Crystal structure Automatic Solution) pipeline is an automatic direct-methods-aided dual-space iterative phasing and model-building procedure. When only an electron-density map is available as the starting point, IPCAS is capable of generating a completed model from the phases of the input map automatically, without the requirement of an initial model. In this study, a hybrid method integrating X-ray crystallography with cryo-EM to help with structure determination is presented. With a cryo-EM map as the starting point, the workflow of the method involves three steps. (1) Cryo-EM map replacement: FSEARCH is utilized to find the correct translation and orientation of the cryo-EM map in the crystallographic unit cell and generates the initial low-resolution map. (2) Phase extension: the phases calculated from the correctly placed cryo-EM map are extended to high-resolution X-ray data by non-crystallographic symmetry averaging with phenix.resolve. (3) Model building: IPCAS is used to generate an initial model using the phase-extended map and perform model completion by iteration. Four cases (the lowest cryo-EM map resolution being 6.9 Å) have been tested for the general applicability of the hybrid method, and almost complete models have been generated for all test cases with reasonable Rwork/Rfree. The hybrid method therefore provides an automated tool for X-ray structure determination using a cryo-EM map as the starting point.
    Keywords: FSEARCHIPCASiterative phasingcryo-EMmodel buildingstructure determinationcryo-electron microscopyX-ray crystallographyphase problem
    Electronic ISSN: 2052-2525
    Topics: Geosciences , Physics
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...