ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 2015-2019  (1,791,103)
  • 2019  (1,014,361)
  • 2017  (776,766)
Collection
Year
  • 1
    facet.materialart.
    Unknown
    Naturalis Biodiversity Center
    In:  Blumea: Biodiversity, Evolution and Biogeography of Plants vol. 64 no. 3, pp. 216-224
    Publication Date: 2024-06-15
    Description: Two new species of Inversodicraea, I. koukoutamba and I. tassing, both from the Republic of Guinea, are described as new to science, increasing the number of species known in this African genus to 32, making it the most species-diverse among African Podostemaceae. Both species are remarkable, among other features, for their styles. Inversodicraea koukoutamba is only the third species of the genus with 3, not 2 styles, and is unique in the genus, and in the family, in having each style bifurcate. Inversodicraea tassing has styles equal or exceeding the length of the ovary, being nearly twice as long as those of the species which previously was noted for the longest styles in the genus. Both new species are single-site endemics, the first is assessed here as Critically Endangered according to the IUCN 2012 standard, due to the incipient construction of the World Bank backed Koukoutamba hydroelectric dam which threatens several other plant species assessed as Critically Endangered or Endangered. The second species, I. tassing, is assessed as Near Threatened, since there are currently no threats known at present to the single known site.
    Keywords: Plant Science ; Ecology ; Evolution ; Behavior and Systematics ; Bafing River ; conservation ; dams ; extinct ; Guinea ; hydroelectricity ; OMVS ; waterfalls ; World Bank
    Repository Name: National Museum of Natural History, Netherlands
    Type: info:eu-repo/semantics/article
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    facet.materialart.
    Unknown
    PANGAEA
    In:  Izaña Atmospheric Research Center, Meteorological State Agency of Spain
    Publication Date: 2024-06-14
    Keywords: Air temperature at 2 m height; BARO; Barometer; Baseline Surface Radiation Network; BSRN; DATE/TIME; Diffuse radiation; Diffuse radiation, maximum; Diffuse radiation, minimum; Diffuse radiation, standard deviation; Direct radiation; Direct radiation, maximum; Direct radiation, minimum; Direct radiation, standard deviation; EKO Instruments, MR-60, SN S15115.07, WRMC No. 61013; HEIGHT above ground; Humidity, relative; HYGRO; Hygrometer; IZA; Izaña; Long-wave downward radiation; Long-wave downward radiation, maximum; Long-wave downward radiation, minimum; Long-wave downward radiation, standard deviation; Long-wave upward radiation; Long-wave upward radiation, maximum; Long-wave upward radiation, minimum; Long-wave upward radiation, standard deviation; Monitoring station; MONS; Net radiation; Net radiation, maximum; Net radiation, minimum; Net radiation, standard deviation; Pyranometer, EKO, MS-802F, SN F15508FR, WRMC No. 61010; Pyranometer, EKO, MS-802F, SN F15509FR, WRMC No. 61011; Pyrgeometer, Kipp & Zonen, CGR4, SN 050783, WRMC No. 61008; Pyrheliometer, EKO, MS-56, SN P15048, WRMC No. 61012; Short-wave downward (GLOBAL) radiation; Short-wave downward (GLOBAL) radiation, maximum; Short-wave downward (GLOBAL) radiation, minimum; Short-wave downward (GLOBAL) radiation, standard deviation; Short-wave upward (REFLEX) radiation; Short-wave upward (REFLEX) radiation, maximum; Short-wave upward (REFLEX) radiation, minimum; Short-wave upward (REFLEX) radiation, standard deviation; Station pressure; Tenerife, Spain; Thermometer
    Type: Dataset
    Format: text/tab-separated-values, 1325568 data points
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    facet.materialart.
    Unknown
    PANGAEA
    In:  Izaña Atmospheric Research Center, Meteorological State Agency of Spain
    Publication Date: 2024-06-14
    Keywords: Air temperature at 2 m height; BARO; Barometer; Baseline Surface Radiation Network; BSRN; DATE/TIME; Diffuse radiation; Diffuse radiation, maximum; Diffuse radiation, minimum; Diffuse radiation, standard deviation; Direct radiation; Direct radiation, maximum; Direct radiation, minimum; Direct radiation, standard deviation; EKO Instruments, MR-60, SN S15115.07, WRMC No. 61013; HEIGHT above ground; Humidity, relative; HYGRO; Hygrometer; IZA; Izaña; Long-wave downward radiation; Long-wave downward radiation, maximum; Long-wave downward radiation, minimum; Long-wave downward radiation, standard deviation; Long-wave upward radiation; Long-wave upward radiation, maximum; Long-wave upward radiation, minimum; Long-wave upward radiation, standard deviation; Monitoring station; MONS; Net radiation; Net radiation, maximum; Net radiation, minimum; Net radiation, standard deviation; Pyranometer, EKO, MS-802F, SN F15508FR, WRMC No. 61010; Pyranometer, EKO, MS-802F, SN F15509FR, WRMC No. 61011; Pyrgeometer, Kipp & Zonen, CGR4, SN 050783, WRMC No. 61008; Pyrheliometer, EKO, MS-56, SN P15048, WRMC No. 61012; Short-wave downward (GLOBAL) radiation; Short-wave downward (GLOBAL) radiation, maximum; Short-wave downward (GLOBAL) radiation, minimum; Short-wave downward (GLOBAL) radiation, standard deviation; Short-wave upward (REFLEX) radiation; Short-wave upward (REFLEX) radiation, maximum; Short-wave upward (REFLEX) radiation, minimum; Short-wave upward (REFLEX) radiation, standard deviation; Station pressure; Tenerife, Spain; Thermometer
    Type: Dataset
    Format: text/tab-separated-values, 1352464 data points
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    facet.materialart.
    Unknown
    PANGAEA
    In:  Meteorology Climatology Remote Sensing, Dep. Umweltwissenschaften, Universität Basel
    Publication Date: 2024-06-14
    Description: In Gobabeb, Namibia SWD, LWD and DIR are each measured redundant with two instruments of the same make (not in this data base). The differences between the pairs are used in the quality control. This is done manually by inspecting plots of half-day diurnal courses of the pairs and their differences. Values are removed mostly in the morning due to daily cleaning. Other reasons for larger differences are birds, insects, or people at the station. There are regular fog events varying in frequency over the year. Usually, the fog appears in the second half of the night and disappears a few hours after sunrise. The case temperatures of pyrgeometers practically never drop below dewpoint but there can be water deposition of the dome.
    Keywords: Air temperature at 2 m height; BARO; Barometer; Baseline Surface Radiation Network; BSRN; DATE/TIME; Diffuse radiation; Diffuse radiation, standard deviation; Direct radiation; Direct radiation, standard deviation; GOB; Gobabeb; HEIGHT above ground; Humidity, relative; HYGRO; Hygrometer; Long-wave downward radiation; Long-wave downward radiation, standard deviation; Long-wave upward radiation; Monitoring station; MONS; Namib Desert, Namibia; Pyranometer, Kipp & Zonen, CMP22, SN 110315, WRMC No. 20100; Pyranometer, Kipp & Zonen, CMP22, SN 110316, WRMC No. 20101; Pyranometer, Kipp & Zonen, CMP22, SN 120330, WRMC No. 20102; Pyrgeometer, Kipp & Zonen, CGR4, SN 110408, WRMC No. 20200; Pyrgeometer, Kipp & Zonen, CGR4, SN 120457, WRMC No. 20201; Pyrheliometer, Kipp & Zonen, CHP 1, SN 110764, WRMC No. 20000; Short-wave downward (GLOBAL) radiation; Short-wave downward (GLOBAL) radiation, standard deviation; Short-wave upward (REFLEX) radiation; Station pressure; Thermometer
    Type: Dataset
    Format: text/tab-separated-values, 570304 data points
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    facet.materialart.
    Unknown
    PANGAEA
    In:  Izaña Atmospheric Research Center, Meteorological State Agency of Spain
    Publication Date: 2024-06-14
    Keywords: Air temperature at 2 m height; BARO; Barometer; Baseline Surface Radiation Network; BSRN; DATE/TIME; Diffuse radiation; Diffuse radiation, maximum; Diffuse radiation, minimum; Diffuse radiation, standard deviation; Direct radiation; Direct radiation, maximum; Direct radiation, minimum; Direct radiation, standard deviation; EKO Instruments, MR-60, SN S15115.07, WRMC No. 61013; HEIGHT above ground; Humidity, relative; HYGRO; Hygrometer; IZA; Izaña; Long-wave downward radiation; Long-wave downward radiation, maximum; Long-wave downward radiation, minimum; Long-wave downward radiation, standard deviation; Long-wave upward radiation; Long-wave upward radiation, maximum; Long-wave upward radiation, minimum; Long-wave upward radiation, standard deviation; Monitoring station; MONS; Net radiation; Net radiation, maximum; Net radiation, minimum; Net radiation, standard deviation; Pyranometer, EKO, MS-802F, SN F15508FR, WRMC No. 61010; Pyranometer, EKO, MS-802F, SN F15509FR, WRMC No. 61011; Pyrgeometer, Kipp & Zonen, CGR4, SN 050783, WRMC No. 61008; Pyrheliometer, EKO, MS-56, SN P15048, WRMC No. 61012; Short-wave downward (GLOBAL) radiation; Short-wave downward (GLOBAL) radiation, maximum; Short-wave downward (GLOBAL) radiation, minimum; Short-wave downward (GLOBAL) radiation, standard deviation; Short-wave upward (REFLEX) radiation; Short-wave upward (REFLEX) radiation, maximum; Short-wave upward (REFLEX) radiation, minimum; Short-wave upward (REFLEX) radiation, standard deviation; Station pressure; Tenerife, Spain; Thermometer
    Type: Dataset
    Format: text/tab-separated-values, 1180451 data points
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    facet.materialart.
    Unknown
    PANGAEA
    In:  Izaña Atmospheric Research Center, Meteorological State Agency of Spain
    Publication Date: 2024-06-14
    Keywords: Air temperature at 2 m height; BARO; Barometer; Baseline Surface Radiation Network; BSRN; DATE/TIME; Diffuse radiation; Diffuse radiation, maximum; Diffuse radiation, minimum; Diffuse radiation, standard deviation; Direct radiation; Direct radiation, maximum; Direct radiation, minimum; Direct radiation, standard deviation; EKO Instruments, MR-60, SN S15115.07, WRMC No. 61013; HEIGHT above ground; Humidity, relative; HYGRO; Hygrometer; IZA; Izaña; Long-wave downward radiation; Long-wave downward radiation, maximum; Long-wave downward radiation, minimum; Long-wave downward radiation, standard deviation; Long-wave upward radiation; Long-wave upward radiation, maximum; Long-wave upward radiation, minimum; Long-wave upward radiation, standard deviation; Monitoring station; MONS; Net radiation; Net radiation, maximum; Net radiation, minimum; Net radiation, standard deviation; Pyranometer, EKO, MS-802F, SN F15508FR, WRMC No. 61010; Pyranometer, EKO, MS-802F, SN F15509FR, WRMC No. 61011; Pyrgeometer, Kipp & Zonen, CGR4, SN 050783, WRMC No. 61008; Pyrheliometer, EKO, MS-56, SN P15048, WRMC No. 61012; Short-wave downward (GLOBAL) radiation; Short-wave downward (GLOBAL) radiation, maximum; Short-wave downward (GLOBAL) radiation, minimum; Short-wave downward (GLOBAL) radiation, standard deviation; Short-wave upward (REFLEX) radiation; Short-wave upward (REFLEX) radiation, maximum; Short-wave upward (REFLEX) radiation, minimum; Short-wave upward (REFLEX) radiation, standard deviation; Station pressure; Tenerife, Spain; Thermometer
    Type: Dataset
    Format: text/tab-separated-values, 1349684 data points
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    facet.materialart.
    Unknown
    PANGAEA
    In:  Izaña Atmospheric Research Center, Meteorological State Agency of Spain
    Publication Date: 2024-06-14
    Keywords: Air temperature at 2 m height; BARO; Barometer; Baseline Surface Radiation Network; BSRN; DATE/TIME; Diffuse radiation; Diffuse radiation, maximum; Diffuse radiation, minimum; Diffuse radiation, standard deviation; Direct radiation; Direct radiation, maximum; Direct radiation, minimum; Direct radiation, standard deviation; EKO Instruments, MR-60, SN S15115.07, WRMC No. 61013; HEIGHT above ground; Humidity, relative; HYGRO; Hygrometer; IZA; Izaña; Long-wave downward radiation; Long-wave downward radiation, maximum; Long-wave downward radiation, minimum; Long-wave downward radiation, standard deviation; Long-wave upward radiation; Long-wave upward radiation, maximum; Long-wave upward radiation, minimum; Long-wave upward radiation, standard deviation; Monitoring station; MONS; Net radiation; Net radiation, maximum; Net radiation, minimum; Net radiation, standard deviation; Pyranometer, EKO, MS-802F, SN F15508FR, WRMC No. 61010; Pyranometer, EKO, MS-802F, SN F15509FR, WRMC No. 61011; Pyrgeometer, Kipp & Zonen, CGR4, SN 050783, WRMC No. 61008; Pyrheliometer, EKO, MS-56, SN P15048, WRMC No. 61012; Short-wave downward (GLOBAL) radiation; Short-wave downward (GLOBAL) radiation, maximum; Short-wave downward (GLOBAL) radiation, minimum; Short-wave downward (GLOBAL) radiation, standard deviation; Short-wave upward (REFLEX) radiation; Short-wave upward (REFLEX) radiation, maximum; Short-wave upward (REFLEX) radiation, minimum; Short-wave upward (REFLEX) radiation, standard deviation; Station pressure; Tenerife, Spain; Thermometer
    Type: Dataset
    Format: text/tab-separated-values, 1301330 data points
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    facet.materialart.
    Unknown
    PANGAEA
    In:  Meteorology Climatology Remote Sensing, Dep. Umweltwissenschaften, Universität Basel
    Publication Date: 2024-06-14
    Description: In Gobabeb, Namibia SWD, LWD and DIR are each measured redundant with two instruments of the same make (not in this data base). The differences between the pairs are used in the quality control. This is done manually by inspecting plots of half-day diurnal courses of the pairs and their differences. Values are removed mostly in the morning due to daily cleaning. Other reasons for larger differences are birds, insects, or people at the station. There are regular fog events varying in frequency over the year. Usually, the fog appears in the second half of the night and disappears a few hours after sunrise. The case temperatures of pyrgeometers practically never drop below dewpoint but there can be water deposition of the dome.
    Keywords: Air temperature at 2 m height; BARO; Barometer; Baseline Surface Radiation Network; BSRN; DATE/TIME; Diffuse radiation; Diffuse radiation, standard deviation; Direct radiation; Direct radiation, standard deviation; GOB; Gobabeb; HEIGHT above ground; Humidity, relative; HYGRO; Hygrometer; Long-wave downward radiation; Long-wave downward radiation, standard deviation; Long-wave upward radiation; Monitoring station; MONS; Namib Desert, Namibia; Pyranometer, Kipp & Zonen, CMP22, SN 110315, WRMC No. 20100; Pyranometer, Kipp & Zonen, CMP22, SN 110316, WRMC No. 20101; Pyranometer, Kipp & Zonen, CMP22, SN 120330, WRMC No. 20102; Pyrgeometer, Kipp & Zonen, CGR4, SN 110408, WRMC No. 20200; Pyrgeometer, Kipp & Zonen, CGR4, SN 120457, WRMC No. 20201; Pyrheliometer, Kipp & Zonen, CHP 1, SN 110764, WRMC No. 20000; Short-wave downward (GLOBAL) radiation; Short-wave downward (GLOBAL) radiation, standard deviation; Short-wave upward (REFLEX) radiation; Station pressure; Thermometer
    Type: Dataset
    Format: text/tab-separated-values, 580182 data points
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Publication Date: 2024-06-14
    Keywords: Acer; AGE; Alchemilla pentaphyllea-type; Allium ursinum-type; Alnus; Anagallis-type; Apiaceae; Artemisia; Asteraceae; Ballota-type; Betula; Brassicaceae; Bryonia/Leonotis; Bupleurum-type; Calystegia; Cannabis/Humulus; Carpinus betulus; Caryophyllaceae; Castanea; Centaurea cyanus-type; Centaurea jacea-type; Centaurea montana-type; Centaurea scabiosa-type; Cerealia-type; cf. Chrozophora; cf. Cornus mas; cf. Cornus sanguinea; cf. Filipendula; cf. Sausurea; cf. Solanum dulcamara; cf. Styrax; Chenopodiaceae; Cichorioideae; Cirsium; Convolvulus arvensis-type; Corylus; Counting, palynology; Cousinia; Cyperaceae; Daphne; DEPTH, sediment/rock; Diospyrus lotus; Eleagnus; Ephedra distachya-type; Ephedra fragilis-type; Epilobium; Eremurus; Euphorbia; Fabaceae; Fagus; Fraxinus excelsior-type; Galium-type; Genista group; Geranium; Geum-type; Hippophae; Hypericum hyssopifolium; Jasione montana-type; Juglans; Juniperus-type; Kongor_Lake; Lemna; Lycopodium (added); Lycopodium spores counted; Lycopodium tablets; Lythrum; Malvaceae; Matricaria-type; Mentha-type; Morus alba; Myrica; Myriophyllum spicatum; Nitraria; Number of batch; Olea; Onobrychis; Ornithogalum umbellatum-type; Ostrya-type; Papaver rhoeas-type; Parrotia persica; Pinus diploxylon-type; Pistacia; Plantago lanceolata-type; Plantago major/media; Plantago maritima-type; Platanus; Plumbaginaceae; Poaceae; pollen; Pollen, reworked; Pollen indeterminata; Polygonum aviculare-type; Polygonum bistorta-type; Populus; Potamogeton natans-type/Triglochin; Potentilla-type; Primulaceae; Primula clusiana-type; Prosopis farcta; Pterocarya; Pteropyrum; Pulmonaria-type; Quercus robur-type; radiocarbon; Ranunculus acris-type; Rhamnus-type; Rheum; Rhinanthus group; Rumex acetosa-type; Salix; Salvia verticillata; Sambucus ebulus; Sambucus nigra-type; Sample volume; Sanguisorba minor-type; Saussurea-type; Secale; SEDCO; Sediment corer; Senecio-type; Solanum dulcamara-type; Solanum nigrum-type; Sorbus group; Sparganium-type; Tamarix; Taxus; Thalictrum; Tilia; Tribulus terrestris; Typha latifolia-type; Ulmus; Valerianella; Varia; Viscum; Vitis; Xanthium spinosum-type; Xanthium strumarium-type; Zelkova
    Type: Dataset
    Format: text/tab-separated-values, 6943 data points
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    facet.materialart.
    Unknown
    PANGAEA
    In:  Meteorology Climatology Remote Sensing, Dep. Umweltwissenschaften, Universität Basel
    Publication Date: 2024-06-14
    Description: In Gobabeb, Namibia SWD, LWD and DIR are each measured redundant with two instruments of the same make (not in this data base). The differences between the pairs are used in the quality control. This is done manually by inspecting plots of half-day diurnal courses of the pairs and their differences. Values are removed mostly in the morning due to daily cleaning. Other reasons for larger differences are birds, insects, or people at the station. There are regular fog events varying in frequency over the year. Usually, the fog appears in the second half of the night and disappears a few hours after sunrise. The case temperatures of pyrgeometers practically never drop below dewpoint but there can be water deposition of the dome.
    Keywords: Air temperature at 2 m height; BARO; Barometer; Baseline Surface Radiation Network; BSRN; DATE/TIME; Diffuse radiation; Diffuse radiation, standard deviation; Direct radiation; Direct radiation, standard deviation; GOB; Gobabeb; HEIGHT above ground; Humidity, relative; HYGRO; Hygrometer; Long-wave downward radiation; Long-wave downward radiation, standard deviation; Long-wave upward radiation; Monitoring station; MONS; Namib Desert, Namibia; Pyranometer, Kipp & Zonen, CMP22, SN 110315, WRMC No. 20100; Pyranometer, Kipp & Zonen, CMP22, SN 110316, WRMC No. 20101; Pyranometer, Kipp & Zonen, CMP22, SN 120330, WRMC No. 20102; Pyrgeometer, Kipp & Zonen, CGR4, SN 110408, WRMC No. 20200; Pyrgeometer, Kipp & Zonen, CGR4, SN 120457, WRMC No. 20201; Pyrheliometer, Kipp & Zonen, CHP 1, SN 110764, WRMC No. 20000; Short-wave downward (GLOBAL) radiation; Short-wave downward (GLOBAL) radiation, standard deviation; Short-wave upward (REFLEX) radiation; Station pressure; Thermometer
    Type: Dataset
    Format: text/tab-separated-values, 524023 data points
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...