ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Articles  (382)
  • Other Sources
  • American Geophysical Union  (341)
  • Munksgaard International Publishers  (41)
  • 2000-2004  (382)
  • 1995-1999
  • 1965-1969
  • 2000  (382)
  • Architecture, Civil Engineering, Surveying  (382)
Collection
  • Articles  (382)
  • Other Sources
Years
  • 2000-2004  (382)
  • 1995-1999
  • 1965-1969
Year
Journal
  • 1
    Electronic Resource
    Electronic Resource
    Copenhagen : Munksgaard International Publishers
    Indoor air 10 (2000), S. 0 
    ISSN: 1600-0668
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Architecture, Civil Engineering, Surveying , Medicine
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Copenhagen : Munksgaard International Publishers
    Indoor air 10 (2000), S. 0 
    ISSN: 1600-0668
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Architecture, Civil Engineering, Surveying , Medicine
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Copenhagen : Munksgaard International Publishers
    Indoor air 10 (2000), S. 0 
    ISSN: 1600-0668
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Architecture, Civil Engineering, Surveying , Medicine
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 1600-0668
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Architecture, Civil Engineering, Surveying , Medicine
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Copenhagen : Munksgaard International Publishers
    Indoor air 10 (2000), S. 0 
    ISSN: 1600-0668
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Architecture, Civil Engineering, Surveying , Medicine
    Notes: Abstract This paper summarizes important new contributions submitted among the many fine health-related papers presented at Indoor Air `99. The paper is a Power Point presentation that may be accessed by the reader at 1. Download the presentation2. Open FILE3. Click PRINT4. The print options for a PowerPoint file are displayed5. Under PRINT WHAT choose NOTES PAGES6. 37 figures will be printed (one per sheet) with the note explaining the figure on each sheet
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Copenhagen : Munksgaard International Publishers
    Indoor air 10 (2000), S. 0 
    ISSN: 1600-0668
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Architecture, Civil Engineering, Surveying , Medicine
    Notes: Abstract This study examines the influence of ventilation on chemical reactions among indoor pollutants. We have used a one compartment mass balance model to simulate unimolecular and bimolecular reactions occurring indoors. The initial modeling assumes steady-state conditions. However, at low air exchange rates, there may be insufficient time to achieve steady-state. Hence we have also modeled non steady-state scenarios. In the cases examined, the results demonstrate that the concentrations of products generated from reactions among indoor pollutants increase as the ventilation rate decreases. This is true for unimolecular and bimolecuar reactions, regardless of whether the pollutants have indoor or outdoor sources. It is also true even when one of the pollutants has an outdoor concentration that displays large diurnal variations. We have supplemented the modeling studies with a series of experiments conducted in typical commercial offices. The reaction examined was that between ozone and limonene. The ozone was present as a consequence of outdoor-to-indoor transport while the limonene originated indoors. Results were obtained for low and high ventilation rates. Consistent with the modeling studies, the concentrations of monitored products were much larger at the lower ventilation rates (even though the ozone concentrations were lower). The potential for reactions among indoor pollutants to generate reactive and irritating products is an additional reason to maintain adequate ventilation in indoor environments. /〉
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Copenhagen : Munksgaard International Publishers
    Indoor air 10 (2000), S. 0 
    ISSN: 1600-0668
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Architecture, Civil Engineering, Surveying , Medicine
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    ISSN: 1600-0668
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Architecture, Civil Engineering, Surveying , Medicine
    Notes: Abstract A sink-diffusion model to describe the interaction between material surfaces and volatile organic compounds (VOCs) in indoor air has been introduced. The model is based on adsorption/desorption on the material surfaces and diffusion into the materials. Test chamber experiments with exposure of nylon carpet and polyvinyl chloride (PVC) covering against α-pinene and toluene were used to validate the model and to make comparisons with a sink model based on the Langmuir adsorption isotherm. The results showed that the sink-diffusion model gave a better description of the desorption curve than the Langmuir model. The model predictions improved with increasing sorption effect. The Langmuir model gave good predictions of relative weak sorption effects, whereas the sink-diffusion model improved the predictions for stronger sorption effects. In this case, nylon carpet showed substantial stronger sorption than PVC covering and α-pinene showed stronger sorption than toluene. Controlled field experiments with combinations of building materials and a mixture of VOCs, encountered in real indoor environments, are needed to further validate the sink-diffusion model.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    ISSN: 1600-0668
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Architecture, Civil Engineering, Surveying , Medicine
    Notes: Abstract A portion of electronic equipment failures is a consequence of particle deposition on electronic circuits in normal indoor environments. Deposited hygroscopic particles reduce the electrical isolation (EI) between conductors. In laboratory experiments, we investigated the mechanisms, locations, and effects of particle deposition on electronic circuits with surface mounted chips (SMCs) and also on small television sets. One set of electronics was exposed for 281 h to an unusually high concentration of artificially-generated ammonium sulfate particles while a second set (experimental controls) was exposed to normal indoor particles. The particle mass concentration in the high-exposure chamber was 500 times higher than normal. Television reliability was observed and the changes in EI between adjacent legs of SMCs were measured. The experiments demonstrate the strong influence of electrostatic forces on the locations and rates of particle deposition. Although televisions did not fail after exposure to concentrated aerosols, the EI between adjacent legs of the SMCs was, in many cases, greatly diminished. Relative humidity had a very strong influence on the magnitude of EI. A qualitative explanation of the mechanisms of particle deposition and circuit degradation is proposed, including the role of fibers. Finally, a potential method to reduce particle deposition on electronic components is discussed.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Copenhagen : Munksgaard International Publishers
    Indoor air 10 (2000), S. 0 
    ISSN: 1600-0668
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Architecture, Civil Engineering, Surveying , Medicine
    Notes: Abstract The American Society for Testing and Materials (ASTM) mouse bioassay, which quantifies airway irritation from reduction in the respiratory rate, was used to find evidence for the formation of highly irritating substances in reactions of ozone with terpenes (common indoor volatile organic compounds (VOCs)). No-observed-effect-levels (NOELs) and concentration-effect relationships were established for ozone, (+)-α-pinene and R-(+)-limonene, isoprene, and some of their major reaction products. Reaction mixtures of excess terpene and ozone considerably below their NOEL concentrations resulted in significant upper airway irritation. The reduction of the respiratory rate was from 30% to about 50%, lowest for the α-pinene and highest for the isoprene mixture. Chemical analysis of reaction mixtures by conventional methods showed that readily identified stable products and residual reactants at the concentrations found could not account for the observed reductions of the respiratory rate, assuming additivity of the reaction products. The results suggest that, in addition to known irritants (formaldehyde, acrolein, methacrolein, methyl vinylketone), one or more strong airway irritant(s) of unknown structure(s) were formed. Future indoor air quality (IAQ) guidelines for unsaturated VOCs (e.g., terpenes) and their emission from building products may require the consideration of reactions with oxidants, like ozone. Similarly, effects of ozone-emitting equipment should be re-evaluated. /〉
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...