ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Articles  (393)
  • Chemistry  (393)
  • Wiley-Blackwell  (393)
  • OpenEdition
  • Wiley
  • 2010-2014
  • 1995-1999  (393)
  • 1985-1989
  • 1945-1949
  • 1997  (393)
  • Medicine  (352)
  • Electrical Engineering, Measurement and Control Technology  (41)
Collection
  • Articles  (393)
Publisher
  • Wiley-Blackwell  (393)
  • OpenEdition
  • Wiley
Years
  • 2010-2014
  • 1995-1999  (393)
  • 1985-1989
  • 1945-1949
Year
  • 1
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Advanced Materials for Optics and Electronics 7 (1997), S. 1-8 
    ISSN: 1057-9257
    Keywords: CdTe ; iodine doping ; electrical activity ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Electrical Engineering, Measurement and Control Technology , Physics
    Notes: The electrical activity of iodine in CdTe is discussed when iodine is introduced into the CdTe by diffusion from the vapour phase. It is compared both with the total concentration of iodine in the diffused CdTe slices and with the electrical activity in CdTe slices which have been annealed under Cd- and Te-saturated vapour pressures.Iodine-diffused slices of CdTe were profiled by secondary ion mass spectrometry (SIMS) to obtain the total iodine concentration and by capacitance-voltage (C-V) techniques to obtain the net concentration of electrically active iodine. After annealing with iodine in the form of Cdl2, the slices were p-type, similar to those obtained when CdTe was annealed in either excess Te or Cd vapour, and they showed no significant increase in electrical activity. If Cd was added to the Cdl2 diffusion source or the CdTe was given a subsequent anneal in cadmium vapour, the slices became n-type. The results indicated that in all cases a neutral layer composed of Cd nIm (m and n are integers) formed on the surface layers, whereas if Cd was involved in the diffusion, some of the iodine existed in an electrically active form deeper into the slice with a maximum concentration of active carriers given by ND - NA ≈ 1017 cm-3. © 1997 John Wiley & Sons Ltd.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1057-9257
    Keywords: organic conductors ; optical spectra ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Electrical Engineering, Measurement and Control Technology , Physics
    Notes: Polarised infrared reflectivity spectra of some ET-based conducting salts of alpha-type structure are measured and compared: (ET)2I3 (I), (ET)2TIHg(XCN)4 (X=S, Se) (II) and (ET)8[Hg4Br12(CH3C6H4CI)2] (III). For both I and II the electronic reflectivity is greater for the polarisation perpendicular to ET stacks. However, a resolved electron vibrational band in the region of 1 100-1 400 cm-1 is observed for II in the polarisation characterized by lower electronic reflectivity in contrast with the spectra of I. Another difference between I and II is the absence of the pronounced plasma edge in the region of 4 000 cm-1 in the spectra of II, which may be due to high electron damping. For III the electronic reflectivity is low and no resolved electron vibrational band in the region of 1 100-1 400 cm-1 is observed. The peculiarities of the electron-vibrational spectra of I, II and III may be due to the details of the crystal structure. © 1997 John Wiley & Sons, Ltd.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Advanced Materials for Optics and Electronics 7 (1997), S. 57-60 
    ISSN: 1057-9257
    Keywords: BETS ; salt ; synthesis ; structure ; conductivity ; magnetoresistance oscillations ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Electrical Engineering, Measurement and Control Technology , Physics
    Notes: New BETS salts (where BETS is bis(ethylenedithio)tetraselenafulvalene) with (CuCl3)x, Cu2C6, Cu4Cl8 and Fe0.75Ga0.25Cl4 anions have been obtained. The crystal structures and electrical and magnetoresistance properties of Κ-BETS4Cu4Cl8, θ-BETS4Cu2Cl6 and Κ-BETS2Fe0.75Ga0.25Cl4 have been studied. The last two compounds have been found to exhibit Shubnikov-de Haas and angle-dependent magnetoresistance oscillations. © 1997 John Wiley & Sons, Ltd.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Advanced Materials for Optics and Electronics 7 (1997), S. 67-69 
    ISSN: 1057-9257
    Keywords: magnetic BEDT-TTF salts ; IR spectra ; Drude-Lorentz model ; charge transfer bands ; C = C stretching vibrations ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Electrical Engineering, Measurement and Control Technology , Physics
    Notes: Polarised reflectance spectra of three charge transfer salts of bis(ethylenedithio)tetrathiafulvalene (BEDT-TTF), β(BEDT-TTF)5M(CN)6 · 10H2O (M ≡ Co, Fe, Cr), are measured in the infrared region 650-6500 cm-1 at room temperature. The reflectance is analysed in terms of the Drude-Lorentz model. Vibrational bands related to C = C stretching are discussed. © 1997 John Wiley & Sons, Ltd.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Advanced Materials for Optics and Electronics 7 (1997), S. 307-310 
    ISSN: 1057-9257
    Keywords: photoreflectance ; photoluminescence ; InGaAs/GaAs quantum well ; type I and II excitonic transition ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Electrical Engineering, Measurement and Control Technology , Physics
    Notes: InGaAs/GaAs MOCVD-grown quantum wells have been investigated. Photoluminescence (PL) measurements have shown heavy-hole-related excitonic transitions within the temperature range from 10 to 100 K for all samples. In room-temperature photoreflectance (PR), sharp heavy- and light-hole excitonic transitions in the quantum wells have been observed. The transition energies obtained have been compared with values derived from theoretical considerations using the envelope function model including lattice-mismatch-related stress. The heavy- and light-hole transitions have been identified as excitonic transitions of types I and II respectively. © 1997 John Wiley & Sons, Ltd.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Advanced Materials for Optics and Electronics 7 (1997), S. 171-182 
    ISSN: 1057-9257
    Keywords: molecular computing ; molecular image-processing devices ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Electrical Engineering, Measurement and Control Technology , Physics
    Notes: The processing of half-tone images by excitable media functioning based on non-linear dynamic mechanisms was studied. The image-processing operations proved to be somewhat more complicated than in the case of black-and-white images. Analogies between the architecture of neural networks and the structural features of excitable media are discussed. The basic information capabilities of excitable media proved to be close to the capabilities of shunting on-centre off-surround feedback networks. © 1997 John Wiley & Sons, Ltd.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    ISSN: 1057-9257
    Keywords: photopolymerisation ; electron microscopy ; molecular modeling ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Electrical Engineering, Measurement and Control Technology , Physics
    Notes: By combining the results obtained from an electron diffraction tilting series with solid state NMR and powder X-ray diffraction, it was possible to determine the unit cell parameters and space group of BPABC crystals grown from DMAA solution both before and after irradiation. Subsequently semi-empirical quantum mechanical and packing energy calculations led to a model structure which agreed well with all the electron diffraction data and thus provided insight into the cross-linking mechanism. © 1997 John Wiley & Sons Ltd.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Advanced Materials for Optics and Electronics 7 (1997), S. 161-170 
    ISSN: 1057-9257
    Keywords: molecular computing ; molecular image-processing devices ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Electrical Engineering, Measurement and Control Technology , Physics
    Notes: Excitable media of Belousov-Zhabotinsky type were used for processing images with several levels of brightness. In this case the image-processing operations proved to be somewhat more complicated than in the case of black-and-white pictures. Excitable media seem to be useful tools for handling some practical applications such as aerial picture processing. Belousov-Zhabotinsky-type media are also simple and convenient experimental models for investigation of the information-processing capabilities of biomolecular systems with complicated non-linear dynamics. © 1997 John Wiley & Sons, Ltd.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Advanced Materials for Optics and Electronics 7 (1997), S. 215-224 
    ISSN: 1057-9257
    Keywords: silicon ; epitaxy ; kinetics ; dynamics ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Electrical Engineering, Measurement and Control Technology , Physics
    Notes: The value of in situ monitoring to study growth dynamics and surface reaction kinetics in a gas source molecular beam epitaxy process is illustrated with reference to the growth of Si films on Si(001) substrates using a beam of disilane (Si2H6). By using a combination of reflection high-energy electron diffraction (RHEED) and reflection anisotropy spectroscopy (RAS), we show first how morphological (long-range order) and local electronic structure effects can be separated in the evaluation of growth dynamics. This involves the measurement of step density changes by RHEED concomitantly with the variation in domain coverage on the Si(001) (2×1)+(1×2) reconstructed surface by RAS. This approach is then extended to investigate the kinetics of hydrogen desorption, which is the rate-limiting step in Si growth from Si2H6. It is shown that over a significant temperature range, zeroth-order kinetics are obeyed and this is explained on the basis of a step-mediated desorption process. Finally we show how this influences the growth rate on substrates of differing degrees of vicinality. © 1997 John Wiley & Sons, Ltd.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Advanced Materials for Optics and Electronics 7 (1997), S. 277-279 
    ISSN: 1057-9257
    Keywords: semiconductor nanoparticles ; adduct ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Electrical Engineering, Measurement and Control Technology , Physics
    Notes: An improved organometallic route to passivated, high-quality crystalline nanodispersed semiconductors has been developed. Thermolysis of the 1:1 triethylamine adduct of dimethylcadmium and a chalcogenide source can be used to grow 3 nm diameter II-VI quantum dots capped with trioctylphosphine oxide. Samples have been characterised by absorption spectroscopy, luminescence spectroscopy and high-resolution transmission electron microscopy. © 1997 John Wiley & Sons, Ltd.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 11
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Advanced Materials for Optics and Electronics 7 (1997), S. 281-293 
    ISSN: 1057-9257
    Keywords: polyparaphenylene ; ion implantation ; doping ; thermoelectric power ; conductivity ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Electrical Engineering, Measurement and Control Technology , Physics
    Notes: A sensitive apparatus for determining the conductivity and thermoelectric power of conducting polymer films at temperatures between 150 and 450 K is described. Brittle polyparaphenylene films doped by ion implantation with either alkali (caesium, sodium) or halogen (iodine) ions are studied by this method. Analysis of the temperature dependence of both conductivity and thermopower shows that the doping process of this conjugated polymer is efficient only when low parameters of implantation are selected and appears around room temperature. At higher temperatures the thermopower exhibits an anomalous evolution that we attribute to oxygen migration. © 1997 John Wiley & Sons, Ltd.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 12
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Advanced Materials for Optics and Electronics 7 (1997), S. 311-316 
    ISSN: 1057-9257
    Keywords: monothiocarbamate ; MOCVD ; cadmium sulphide ; precursor ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Electrical Engineering, Measurement and Control Technology , Physics
    Notes: Thin films of CdS were grown by low-pressure metalorganic chemical vapour deposition (LP-MOCVD, 10-2 Torr) on GaAs(100) and borosilicate glass using the novel single-source precursor bis(diethylmonothiocarbamato)cadmium(II). The deposition of CdS was observed at substrate temperatures of 300 °C and above. Uniform adherent films of CdS were grown on GaAs(100) at temperatures between 350 and 450°C. CdS films deposited on glass were generally transparent with small crystallites (∽50 nm). Films were characterised by X-ray diffraction and scanning electron microscopy and shown to be of hexagonal phase. A band gap of 2.39 eV was measured for the films of CdS. © 1997 John Wiley & Sons, Ltd.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 13
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Advanced Materials for Optics and Electronics 7 (1997), S. 23-28 
    ISSN: 1057-9257
    Keywords: dimethylzinc ; purification ; adduct ; non-chelating diamine ; X-ray structure ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Electrical Engineering, Measurement and Control Technology , Physics
    Notes: The structure of the dimethylzinc adduct with the bidentate amine 1,3-bis(4-pyridyl)propane, [Me2Zn(C5H4N)CH2CH2CH2(C5H4N)]n, 1, has been determined by X-ray diffraction analysis. Crystals of 1 are monoclinic, space group P21/m, with two molecules within a unit cell of dimensions a=5.364(3) Å, b=12.839(3) Å, c=10.618(3) Å and β=92.76(3)°. The structure is polymeric, being composed of [Me2Zn(C5H4N)CH2CH2CH2(C5H4N)] units with the nitrogens within a specific 1,3-bis(4-pyridyl)propane ligand bonding to adjacent zinc centres. The zinc atom is four-co-ordinate, bonding to two carbon and two nitrogen atoms, with the C - Zn - C angle of 145.5(2)° intermediate between that of a linear and tetrahedral bond arrangement. As far as we know, this is the first example of a polymeric alkyl zinc/cadmium amine adduct to have been structurally characterised. © 1997 John Wiley & Sons, Ltd.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 14
    ISSN: 1057-9257
    Keywords: tetrathiafulvalenes ; cation radical inner salts (betaines) ; intermolecular hydrogen bonds ; uracil derivatives ; guanine analogues ; DC electrical conductivity ; organic semiconductors ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Electrical Engineering, Measurement and Control Technology , Physics
    Notes: Dimethyl[2,4-dioxo(1 H,3 H)pyrimido]tetrathiafulvalene (1) and dimethyl-[2-amino-4-oxo(3 H)pyrimido]tetrathiafulvalene (4) form unusual inner salts by oxidation in the presence of bases. The insoluble black-green betaines 2 and 5 react with acids to form cation radical salts. Betaine 2 in the presence of acid and bis-(ethylenedithio)tetrathiafulvalene forms the unexpected double salt 8. In order to synthesise the cation radical salts of 1 and 4, it is necessary to use the ultrasonic method owing to the insolubility of the starting compounds. Electrical measurements of the betaines and cation radical salts in pressed samples show an unexpectedly low resistivity with semiconducting character: for betaine 2 ρ(RT) = 840 Ο cm, for betaine 5 ρ(RT) = 10 Ο cm, for salt 7 ρ(RT) = 40 Ο cm, but for double salt 8 ρ(RT) = 50 Ο cm. In the case of salt 8, very low values of activation energy of electrical conductivity of the order of kT were observed. The synthesis and purification of tetrathiafulvalene 4 from 5-amino-7-oxo(6 H)-1,3-dithiolo[4,5-d]pyrimidineselone-2 are described. © 1997 John Wiley & Sons, Ltd.
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 15
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Advanced Materials for Optics and Electronics 7 (1997), S. 83-86 
    ISSN: 1057-9257
    Keywords: photoluminescence ; time-resolved fast spectrocopy ; photoinduced absorption spectroscopy ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Electrical Engineering, Measurement and Control Technology , Physics
    Notes: We have studied the photophysics of linear trans-quinacridone films by applying a variety of transient and continuous wave photomodulation techniques. Our experimental results demonstrate the ultrafast formation of excimer species which are responsible for the emission. The excimer decay kinetics seems to suggest a predominantly charge transfer character of these emitting species. This is consistent with the long-lived states which we detected on the millisecond time scale. © 1997 John Wiley & Sons, Ltd.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 16
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Advanced Materials for Optics and Electronics 7 (1997), S. 71-77 
    ISSN: 1057-9257
    Keywords: Monte Carlo simulation method ; nematic liquid crystal ; electric-field-induced Fréedericksz transition ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Electrical Engineering, Measurement and Control Technology , Physics
    Notes: In this paper we present results of the Monte Carlo simulation of a 2D nematic liquid crystal model in the presence of an externally applied electric field. The molecular interactions were described by the Lebwohl-Lasher Hamiltonian. The boundary conditions employed in the simulations corresponded to the experimental configuration frequently used for establishing the Frank elastic constants. The results are compared with the predictions of the phenomenological Ericksen theory. Preliminary results of simulations of an experimentally important case corresponding to the nematic interacting with a spatially modulated electric fluid are presented. © 1997 John Wiley & Sons, Ltd.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 17
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Advanced Materials for Optics and Electronics 7 (1997), S. 117-121 
    ISSN: 1057-9257
    Keywords: precursor ; MOCVD ; vapour pressure ; adduct ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Electrical Engineering, Measurement and Control Technology , Physics
    Notes: The vapour pressures of mixtures of dimethylzinc with triethylamine (1), 1,3,5-trimethyl- (2) and 1,3,5-triethylhexahydro-1,3,5-triazine (3) have been studied using static measurement at various mole ratios of ligand to alkyl at 0°C. The results obtained are useful in assessing the suitability of these compounds as precursors for the deposition of group-12-containing materials by MOCVD. © 1997 John Wiley & Sons, Ltd.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 18
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Advanced Materials for Optics and Electronics 7 (1997), S. 149-156 
    ISSN: 1057-9257
    Keywords: polyaniline ; synthesis ; surface tension effect ; morphology ; SEM ; ESR ; electrical conductivity ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Electrical Engineering, Measurement and Control Technology , Physics
    Notes: Polyaniline (PANI) prepared in water or a water-methanol (1:1) mixed solvent by anodic oxidation of aniline hydrochloride at a potential of 0.8 V (and higher) vs. Ag/AgCl appears to form microrods of almost uniform shape and dimensions: a diameter of 0.7 μm and a length of 2-3 μm or more. A surface point contact Pt or Ir electrode has been used as the working electrode to get a better ordering in the product due to the surface tension effect. The structure observed with a scanning electron microscope (SEM) is complex: the sample is highly porous and looks like a coral reef; the average channel diameter is 1.5 and 2.5 μm for narrow and wide channels respectively. The rods appearing in great number in the sample are surprisingly uniform, particularly with respect to the diameter. The electrical conductivity is of the order of 10-1 S cm-1 for most samples examined. The electron spin resonance (ESR) spectra consist of a strong singlet line (g = 2.0030-2.0039, ΔH =;0.12-0.50 mT); similarly, the infrared (IR) spectra show a strong and broad absorption due to electron excitations and electron-lattice interactions, which we have observed previously for many PANI samples examined in our laboratory. © 1997 John Wiley & Sons, Ltd.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 19
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Advanced Materials for Optics and Electronics 7 (1997), S. 99-103 
    ISSN: 1057-9257
    Keywords: amorphous molecular solids ; poly(N-epoxypropylcarbazole) ; thermoluminescence ; charge trapping ; charge transport ; energetic disorder ; dipole moments ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Electrical Engineering, Measurement and Control Technology , Physics
    Notes: The low-temperature thermoluminescence (TL) technique has been applied for probing the energetic disorder in doped poly(N-epoxypropylcarbazole)(PEPC) polymer films. Strong polar dopants were used for varying the degree of dipolar disorder. It was found that (1) the TL of the studied systems can be well interpreted in terms of the disorder model and (2) TL spectroscopy can provide the shape of the deepest part of the localised state distribution and the degree of energetic disorder as well. The charge trap distribution on the high-temperature side of the TL peak appears to be a Gaussian function and its halfwidth correlates well with the disorder parameter obtained from charge transport measurements. An unusual electric field effect on the TL of PEPC doped with strong polar dopants was found and is explained in terms of the contribution of the charge-dipole interaction to the energy of localised states. This effect indicates that the TL phenomenon for the studied systems cannot be explained purely by molecular γ-relaxation in the polymer. © 1997 John Wiley & Sons, Ltd.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 20
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Advanced Materials for Optics and Electronics 7 (1997), S. 135-139 
    ISSN: 1057-9257
    Keywords: reaction-diffusion media ; chemical processors ; parallel computing ; cellular automata ; image processing ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Electrical Engineering, Measurement and Control Technology , Physics
    Notes: In this paper we give a regular proof of the viability of the theory of reaction-diffusion computing. The test problem is to approximate the skeleton of a planar contour, i.e. select sites of centres of bitangent circles which lie wholly within the contour. We have designed both a cellular automaton model and a real prototype of a chemical processor that implement skeleton transformations. In the cellular automaton, segments of the discrete skeleton are computed via interactions of excitation waves, while in the chemical processor the underlying mechanism is the formation of Prussian blue in an agar gel film. © 1997 John Wiley & Sons, Ltd.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 21
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Advanced Materials for Optics and Electronics 7 (1997), S. 45-50 
    ISSN: 1057-9257
    Keywords: molecular electronics ; photodiode ; rectifier ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Electrical Engineering, Measurement and Control Technology , Physics
    Notes: A few-monolayer zwitterionic, non-centrosymmetric Langmuir-Blodgett film has been sandwiched between two electrodes, one of which is transparent. Curves of dark current density as a function of applied bias were observed to exhibit rectifier-like behaviour and to follow closely the dependences measured from junctions using two metallic electrodes. The transparent indium tin oxide (ITO) electrode discussed here permitted illumination of the organic film during electrical characterisation and it was observed that the electrical behaviour was altered from the dark state. Illumination has the effect of generating a photocurrent even when no bias is applied to the electrodes; in addition, the junction conductance was increased. © 1997 John Wiley & Sons, Ltd.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 22
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Advanced Materials for Optics and Electronics 7 (1997), S. 79-82 
    ISSN: 1057-9257
    Keywords: organic conductors ; optical spectra ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Electrical Engineering, Measurement and Control Technology , Physics
    Notes: Polarised infrared reflectivity spectra of some ET-based conducting salts of alpha-type structure are measured and compared: (ET)2I3 (I), (ET)2TIHg(XCN)4 (X≡S, Se) (II) and (ET)8[Hg4Br12(CH3C6H4Cl)2] (III). For both I and II the electronic reflectivity is greater for the polarisation perpendicular to ET stacks. However, a resolved electron vibrational band in the region of 1 100-1 400 cm-1 is observed for II in the polarisation characterised by lower electronic reflectivity in contrast with the spectra of I. Another difference between I and II is the absence of the pronounced plasma edge in the region of 4 000 cm-1 in the spectra of II, which may be due to high electron damping. For III the electronic reflectivity is low and no resolved electron vibrational band in the region of 1 100-1 400 cm-1 is observed. The peculiarities of the electron-vibrational spectra of I, II and III may be due to the details of the crystal structure. © 1997 John Wiley & Sons, Ltd.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 23
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Advanced Materials for Optics and Electronics 7 (1997), S. 61-65 
    ISSN: 1057-9257
    Keywords: silicon backbone polymers ; transport properties ; transient photoconductivity ; light generation efficiency ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Electrical Engineering, Measurement and Control Technology , Physics
    Notes: Transient space-charge-limited currents (T-SCLCs) were used as a method for examining drift mobility, recombination and transport mechanisms for a typical poly(silylene), poly(methylphenylsilylene) (PMPSi). It was found that T-SCLCs present a unique possibility for injecting constant charge into a material with strong dependence of the generation efficiency on the electric field strength. This charge is given by space charge limitations and is thus independent of the transport properties of the material. The post-transit T-SCLC hole emission signals from deep traps have been measured using post-transit T-SCLCs. A density-of-electron-states distribution for deep trapping hole states with a tail-like exponential and a Gaussian distribution centred at 0.55 eV were found. © 1997 John Wiley & Sons, Ltd.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 24
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Advanced Materials for Optics and Electronics 7 (1997), S. 55-55 
    ISSN: 1057-9257
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Electrical Engineering, Measurement and Control Technology , Physics
    Notes: This issue contains papers presented at the 7th International Conference on Electrical and Related Properties of Organic Solids (ERPOS-7). It is a companion issue to Vol. 6. No. 5/6 which contained the bulk of the papers. Unfortunately, not all of the papers could be published in one special issue. © 1997 John Wiley & Sons, Ltd.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 25
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Advanced Materials for Optics and Electronics 7 (1997), S. 123-133 
    ISSN: 1057-9257
    Keywords: nanocomposites ; sol-gel ; heteropolymetallates ; photochromics ; holographic data storage ; amplitude grating ; two-wave-mixing recording ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Electrical Engineering, Measurement and Control Technology , Physics
    Notes: This paper describes the properties of some new organic-inorganic photochromic layers. They are based on a hybrid organic-inorganic matrix in which tungsten heteropolyoxometallates (SiW12O4-40, PW12O3-40) are entrapped in a network obtained from the reaction of 3-glycidoxy-propyltrimethoxysilane. The high homogeneity of these materials on the nanoscale leads to transparent monoliths and layers of controlled thicknesses up to 40 μm. The optical properties of the blend are emphasised and the construction of amplitude gratings in the materials by two-wave-mixing experiments is described. The results of the optical experiments and the comparison with the theoretical background are used as a model for photochromic holographic storage processes. © 1997 John Wiley & Sons, Ltd.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 26
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Advanced Materials for Optics and Electronics 7 (1997), S. 207-211 
    ISSN: 1057-9257
    Keywords: amorphous molecular semiconductor ; dye ; triplet exciplex ; photoconductivity ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Electrical Engineering, Measurement and Control Technology , Physics
    Notes: Results of investigation of the processes of charge carrier photogeneration and relaxation within the exciplex absorption region in films of poly-N-epoxypropylcarbazole doped with the dye rhodamine 6G are given. When the films are illuminated with light from the dye absorption region, new centres of charge photogeneration appear that absorb within the exciplex absorption region. It is shown for the first time that these centres have a long lifetime at room temperature and their temporal concentration changes correlate with EPR photosignal changes. The concentration of centres is independent of the external electric field strength during their generation. These centres are identified as triplet exciplexes. © 1997 John Wiley & Sons, Ltd.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 27
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Advanced Materials for Optics and Electronics 7 (1997), S. 225-231 
    ISSN: 1057-9257
    Keywords: vanadium pentoxide thin films ; electron beam evaporation ; optical properties ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Electrical Engineering, Measurement and Control Technology , Physics
    Notes: Thin films of vanadium pentoxide have been prepared by the electron beam evaporation technique over a wide range of substrate temperatures. Spectrophotometric investigations have been made on these films in the wavelength range 350-1500 nm to determine the nature of the optically induced transition and the optical band gap. A better fit for the direct forbidden transition than for the indirect allowed transition is observed in all the films. The optical band gap is found to decrease with increasing substrate temperature and the subsequent appearance of a broadband absorption at about 1000 nm is attributed to the oxygen vacancies in the films. The effect of heat treatment in vacuum and oxygen ambient on the optical properties of these films is also reported. © 1997 John Wiley & Sons, Ltd.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 28
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Advanced Materials for Optics and Electronics 7 (1997), S. 255-261 
    ISSN: 1057-9257
    Keywords: amorphous molecular semiconductors ; electron-hole pairs ; excitons ; photoconductivity ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Electrical Engineering, Measurement and Control Technology , Physics
    Notes: The photoconductivity of films of amorphous molecular semiconductors increases upon simultaneous photogeneration of singlet electron-hole pairs (EHPs) and triplet excitons and decreases upon photogeneration of triplet EHPs and triplet excitons. An increase in external electric field strength leads to a decrease in the effect of triplet excitons on the film photoconductivity caused by EHP dissociation. It is concluded that under increasing external electric field strength the mobility of charge carriers increases and the velocity of EHP dissociation becomes comparable with the velocity of spin conversion of EHPs interacting with triplet excitons. © 1997 John Wiley & Sons, Ltd.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 29
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Advanced Materials for Optics and Electronics 7 (1997), S. 29-34 
    ISSN: 1057-9257
    Keywords: CdTe ; thin films ; ethylene-glycol bath ; photocurrent ; flat-band potential ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Electrical Engineering, Measurement and Control Technology , Physics
    Notes: CdTe films were deposited on Ni and conducting glass (SnO2) substrates from an ethylene-glycol-based bath by galvanostatic and potentiostatic methods. The film composition and electrical properties depend on parameters such as working electrode potential current density, deposition temperature, substrate type and post-deposition treatments. It is possible to improve the grain size and stoichiometry of the film by post-deposition heat treatment in air. The conductivity type was determined from the photocurrent-working electrode potential behaviour of the film. Dark capacitance measurements in a 0.5 M H2SO4 solution at 10 kHz showed a linear behaviour, from which the flatband potential Vfb= -0.365 V vs. a saturated calomel electrode (SCE) and the doping density ND = 1.35 × 1018 cm-3 were determined. © 1997 John Wiley & Sons, Ltd.
    Additional Material: 10 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 30
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Advanced Materials for Optics and Electronics 7 (1997), S. 35-38 
    ISSN: 1057-9257
    Keywords: photoluminescence ; time-resolved fast spectrocopy ; photoinduced absorption spectroscopy ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Electrical Engineering, Measurement and Control Technology , Physics
    Notes: We have studied the photophysics of linear trans-quinacridone films by applying a variety of transient and continuous wave photomodulation techniques. Our experimental results demonstrate the ultrafast formation of excimer species which are responsible for the emission. The excimer decay kinetics seems to suggest a predominantly charge transfer character of these emitting species. This is consistent with the long-lived states which we detected on the millisecond time scale. © 1997 John Wiley & Sons, Ltd.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 31
    ISSN: 1057-9257
    Keywords: tetrathiafulvalenes ; cation radical inner salts (betaines) ; intermolecular hydrogen bonds ; uracil derivatives ; guanine analogues ; DC electrical conductivity ; organic semiconductors ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Electrical Engineering, Measurement and Control Technology , Physics
    Notes: Dimethyl[2,4-dioxo(1 H,3 H)pyrimido]tetrathiafulvalene (1) and dimethyl-[2-amino-4-oxo(3 H)pyrimido]tetrathiafulvalene (4) form unusual inner salts by oxidation in the presence of bases. The insoluble black-green betaines 2 and 5 react with acids to form cation radical salts. Betaine 2 in the presence of acid and bis-(ethylenedithio)tetrathiafulvalene forms the unexpected double salt 8. In order to synthesise the cation radical salts of 1 and 4, it is necessary to use the ultrasonic method owing to the insolubility of the starting compounds. Electrical measurements of the betaines and cation radical salts in pressed samples show an unexpectedly low resistivity with semiconducting character: for betaine 2 ρ(RT) = 840 Ω cm, for betaine 5 ρ(RT) = 10 Ω cm, for salt 7 ρ(RT) = 40 Ω cm, but for double salt 8 ρ(RT) = 50 Ω cm. In the case of salt 8, very low values of activation energy of electrical conductivity of the order of kT were observed. The synthesis and purification of tetrathiafulvalene 4 from 5-amino-7-oxo(6 H)-1,3-dithiolo[4,5-d]pyrimidineselone-2 are described. © 1997 John Wiley & Sons, Ltd.
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 32
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Advanced Materials for Optics and Electronics 7 (1997), S. 87-91 
    ISSN: 1057-9257
    Keywords: 1,4-cis-polybutadiene ; direct conduction ; hopping ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Electrical Engineering, Measurement and Control Technology , Physics
    Notes: This paper contains results on electrical conduction in 1,4-cis-polybutadiene. Measurements were performed for thin films of thickness from 1 to 10 um with gold and aluminium electrodes. Study was made in the temperature range from 15 to 325 K for two types of polybutadienes: (1) containing 100% of cis form, from Aldrich; (2) containing 96% of cis form, from Philips Petroleum Co. It was found that direct conduction is determined by the Poole-Frenkel effect with some hopping and the Schottky effect. Evaluation of activation energies gave results from 0.3 to 0.36 eV. © 1997 John Wiley & Sons, Ltd.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 33
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Advanced Materials for Optics and Electronics 7 (1997), S. 109-115 
    ISSN: 1057-9257
    Keywords: Cd1-xZnxTe thin films ; optical constants ; spectroscopic ellipsometry ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Electrical Engineering, Measurement and Control Technology , Physics
    Notes: Spectroscopic ellipsometry has been used to determine the optical constants - complex dielectric constant (ε* = ε1+ε2), refractive index (n), extinction coefficient (k), absorption coefficient (α) and normal incidence reflectivity (R) - of two-source vacuum-evaporated polycrystalline Cd1-xZnxTe thin films formed on Corning 7059 glass substrates. The experimental spectra were measured in the photon energy range 1.1-5.6 eV. The spectra revealed distinct peaks at energies corresponding to interband transitions. © 1997 John Wiley & Sons, Ltd.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 34
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Advanced Materials for Optics and Electronics 7 (1997), S. 141-148 
    ISSN: 1057-9257
    Keywords: atomic force microscopy ; thin molecular films ; lithography ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Electrical Engineering, Measurement and Control Technology , Physics
    Notes: In this paper we present results concerning the development of a lithographic technique suitable for application to Langmuir-Blodgett films. Controlled ablations of well-defined portions of the film have been made by using a scanning force microscope (SFM). We report the values of the microscope operational parameters that have allowed us either to perform non-destructive imaging or to obtain reproducible ablations of controlled depth. In particular, our analysis has pointed out the importance of the scanning speed in giving rise to such surface modifications. © 1997 John Wiley & Sons, Ltd.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 35
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Advanced Materials for Optics and Electronics 7 (1997), S. 183-193 
    ISSN: 1057-9257
    Keywords: GaAs ; redistribution of dopants ; ideal static induction transistor (ISIT) ; molecular layer epitaxy (MLE) ; SIMS ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Electrical Engineering, Measurement and Control Technology , Physics
    Notes: An ideal static induction transistor (ISIT) structure was fabricated using molecular layer epitaxy (MLE). The doping method of MLE enabled us to achieve a sufficiently high level of doping for ISIT fabrication. In the fabrication process a low growth temperature was very important for the device structure, which requires very sharp dopant profiles. For the ISIT, two MLE processes, namely source-drain growth and gate regrowth, were required. The electrical characteristics of the source-drain were changed after heat treatment at a temperature higher than 480°C. The effect of the redistribution of dopants of the source-drain structure (n++-i-p++-i-n+) during gate regrowth was clearly shown by SIMS (secondary ion mass spectroscopy) measurements for various temperatures of heat treatment. As a result the doped Se diffused from the n++ source region to the other layers and the doped Zn diffused from the p++ layer to the i-layers. The source was a heavily Se-doped layer at the doping level of (2-3)×1019 cm-3 containing a larger amount of interstitial Se atoms in the lattice. The redistribution of Se from the heavily doped region was detectable even after heat treatment at 480°C for 30 min. For the p++ layer the profile of the C-doped layer was stable even after heat treatment at 620°C for 30 min, but the profile of Zn changed markedly after heat treatment at 480°C for 30 min. In addition, the carbon-doped p++ layer acted as a gettering layer for diffused interstitial Se from the source region. The driving force of the redistribution of dopants results in the electric field in the device structures. © 1997 John Wiley & Sons, Ltd.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 36
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Advanced Materials for Optics and Electronics 7 (1997), S. 233-240 
    ISSN: 1057-9257
    Keywords: thermal stability ; DSC ; group 13 metalorganic compounds ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Electrical Engineering, Measurement and Control Technology , Physics
    Notes: The thermal stabilities of a range of group 13 metalorganic compounds previously used as precursors in metalorganic vapour phase epitaxy (MOVPE) or chemical beam epitaxy (CBE) have been investigated using differential scanning calorimetry (DSC). For the trialkyl compounds R3M the thermal stability decreases in the order M≡Al〉Ga〉In and R≡Me〉Et〉iPr〉tBu and the formation of adducts R3ML (L≡OR2, NR3, etc.) leads to an increase in thermal stability. Dialkylaluminium hydride compounds (e.g. Me2AlH) gave the largest energy release. © 1997 John Wiley & Sons, Ltd.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 37
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Advanced Materials for Optics and Electronics 7 (1997), S. 263-272 
    ISSN: 1057-9257
    Keywords: excitable media ; cellular automata ; universal computer ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Electrical Engineering, Measurement and Control Technology , Physics
    Notes: In this paper we address the problem of how to build a universal computer in an excitable medium. We construct a cellular automata model of a two-dimensional excitable medium (the 2 + medium) evolving in discrete time, with the following properties: every element of the medium has three states (rest, excited and refractory); an element interacts with the eight closest elements; an element in the rest state becomes excited only if exactly two of its eight neighbours are excited. To prove that the 2+ medium is a minimal cellular automata model of a physical universal computing system, we design the minimal logical gates NOT, AND and NOT-AND. © 1997 John Wiley & Sons, Ltd.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 38
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Advanced Materials for Optics and Electronics 7 (1997), S. 295-305 
    ISSN: 1057-9257
    Keywords: Langmuir-Blodgett film ; p-cyanophenyl ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Electrical Engineering, Measurement and Control Technology , Physics
    Notes: Langmuir films and Langmuir-Blodgett deposition have been studied for 2,6-dioctadecyl-aminomethyl-4-cyanophenol (CPR2R2) and 2-dioctadecyl-aminomethyl-4-cyanophenol (CPR2). Stable Langmuir films were obtainable for both compounds at high pH, but only for CPR2R2 at low pH. Molecular modelling and semiempirical MNDO calculations suggest that high pH favours stability by disrupting intramolecular hydrogen bonding. X-ray diffraction on Y-type Langmuir-Blodgett films deposited on hydrophobic glass substrates gives layer spacings of about 56 A3 for both compounds, indicating that the alkyl chains orient perpendicular to the substrate. Modelling and MNDO calculations suggest that analogous compounds with a single octadecyl chain on nitrogen could be stable at both low and high pH. © 1997 John Wiley & Sons, Ltd.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 39
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Advanced Materials for Optics and Electronics 7 (1997), S. 195-206 
    ISSN: 1057-9257
    Keywords: cubic silicon carbide ; morphology ; photoluminescence ; micro-Raman ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Electrical Engineering, Measurement and Control Technology , Physics
    Notes: Optically transparent cubic SiC crystals were grown via atmospheric-pressure chemical vapour deposition (APCVD) on graphite substrates from methyltrichlorosilane (MTS) in hydrogen in a cold-wall RF induction furnace at temperatures from 1500 to 2000°C. The morphology of the crystals was correlated to substrate temperature, H2/MTS ratio and hydrogen flow. Low-temperature photoluminescence (PL) spectra exhibited a zero-phonon line (2.3787 eV) attributable to an exciton bound to a neutral nitrogen donor, in addition to TA, LA, TO, and LO phonon replicas. The observed broadening and splitting of the PL spectral lines were associated with the morphological habit and internal strain of individual crystallites.Above about 1600°C preferential 〈110〉 growth directions were identified for the majority of the crystals. At intermediate deposition temperatures (1600-1700°C) the dominant morphology consisted of yellow prismatic crystals heavily twinned along {111} and {111¯}. At temperatures of about 1750°C hexagonally shaped {111}-oriented 3C-SiC platelets were formed with alternating {001}/{101} edges. A layer-by-layer growth model was used to rationalise the transition in preferred growth direction from 〈111〉 to 〈101〉 with increasing substrate temperature. © 1997 John Wiley & Sons, Ltd.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 40
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Advanced Materials for Optics and Electronics 7 (1997), S. 241-247 
    ISSN: 1057-9257
    Keywords: photoreflectance ; low-dimensional structure ; GaAs ; AlGaAs ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Electrical Engineering, Measurement and Control Technology , Physics
    Notes: Results of room-temperature photoreflectance measurements on three GaAs/Al0.33Ga0.67As multiquantum well (MQW) structures with three different widths of wells and on two GaAs/Al0.33Ga0.67As high-electron-mobility transistor (HEMT) structures are presented. Energy-gap-related transitions in GaAs and AlGaAs were observed. The Al content in AlGaAs was determined. MQW transition energies were determined using the first derivative of a Gaussian profile of the measured resonances. In order to identify the transitions in the MQS, the experimentally observed energies were compared with results of the envelope function calculation method for a rectangular quantum well. The Franz-Keldysh oscillation (FKO) model was also used to determine the built-in electric field in various parts of the investigated structures. The values of the electric fields allow us to hypothesise about the origin of these fields. © 1997 John Wiley & Sons, Ltd.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 41
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Advanced Materials for Optics and Electronics 7 (1997), S. 249-254 
    ISSN: 1057-9257
    Keywords: laser ablation ; ZrO2 ; electroless metallisation ; diffuse reflectance spectra ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Electrical Engineering, Measurement and Control Technology , Physics
    Notes: Experimental results are presented on modifications of the surface properties of ZrO2 ceramics exposed in air to radiation of either a KrF laser (λ=248 nm) or an ArF laser (λ=193 nm) with a pulse duration of 15-20 ns. The modifications of their diffuse reflectance spectra (DRS) are studied as a function of the laser beam parameters. The ablated parts of ZrO2 take on the ability to reduce metals (Cu or Ni) from their respective electroless plating solutions. The electrolessly deposited metal can be patterned via local annealing of the ablated areas with the help of a CW laser, either Ar+ or CO2. The catalytic activity of laser-treated ZrO2 ceramics towards the electroless deposition of metals is discussed from the viewpoint of the formation of an oxygen-deficient surface under laser ablation. The possibility of ZrO2 activation for electroless metal deposition using a scanning beam of a low-power CO2 laser is demonstrated. © 1997 John Wiley & Sons, Ltd.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 42
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 34 (1997), S. 171-175 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: One cause of aseptic loosening of cemented total hip arthroplasty is mechanical weakness at the interface between the metal stem and the cured bone cement. Adhesive acrylic bone cement containing 4-methacryloyloxyethyl trimellitate anhydride (4-META) was applied as a metal coating material to increase the strength of the cemented fixation. The 4-META cement has 2-3 times greater tensile bond strength to metals than does commercial acrylic bone cement. The shear strength of the coated metals fixed with bone cement was approximately 4 times greater in SUS-304 and 3 times greater in titanium (Ti) alloy than those of uncoated metals, and this strength did not decrease after 1 week's immersion in saline. The coating process using the 4-META cement can be performed at normal room temperature, so that metal stems for bone cement fixation could be coated during the course of an operation resulting in potentially improved results of total hip arthroplasty. © 1997 John Wiley & Sons, Inc.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 43
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 34 (1997), S. 201-209 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Adhesion of yeasts and bacteria to silicone rubber is one of the first steps in the biodeterioration of silicone rubber voice prostheses. In this paper, adhesion of two streptococcal, staphylococcal, Candida albicans and Candida tropicalis strains, isolated from explanted voice prostheses was investigated to silicone rubber with and without a salivary conditioning film in a parallel-plate flow chamber. Within each microbial pair of one species, the strain with the most negative zeta potential adhered most slowly to negatively charged silicone rubber. No other clear relationships were obvious between adhesion to silicone rubber and microbial zeta potentials or cell-surface hydrophobicities, as by water contact angles. A 1.5-h adsorbed salivary conditioning film appeared to possess components, presumably albumin and lysozyme, slowing down the deposition of the yeasts and some of the streptococcal and staphylococcal isolates. In addition, microbial adhesion in a stationary end point was generally lower to silicone rubber with an adsorbed salivary conditioning film than without one. Nearly all microorganisms adhering to an adsorbed salivary conditioning film, yeasts as well as bacteria, were stimulated to detach by the passage of an air bubble through the chamber, but microorganisms adhering directly to the silicone rubber, especially C tropicalis strains, detached in far lower numbers under the influence of a passing air bubble. The present observations are in agreement with clinical in vivo findings that in patients with reduced saliva production after radiotherapy, the device life of the voice prosthesis is significantly shortened and suggests that isolated salivary components might be used as an anti-adhesive. © 1997 John Wiley & Sons, Inc.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 44
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 34 (1997), S. 1-8 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: We examined the influence of aging on the implant-bone interface of titanium implants inserted transcortically and extending into the medullary canal of rat tibiae, and quantitatively assessed the differences in bone reaction using an image processing system. Three groups of 15 female rats, aged 6 weeks (young group), 22 weeks (adult group), and 80 weeks (old group) were used in this experiment. The animals were sacrificed 28 days after implant placement. Toluidine blue stained undecalcified sections were prepared for histological observation and image analysis, and the implant socket was observed by SEM. There was no difference in the degree of maturation of newly formed bone between the young and adult groups. Titanium implants inserted in the young and adult groups were surrounded with a bone layer. In the old group, however, there was little mature bone tissue around the implants. Quantitative evaluation indicated that the young group showed the highest, the adult group showed a slightly lower, and the old group showed the lowest percent bone contact, thickness of bone contact, and area of bone surrounding the implant. © 1997 John Wiley & Sons, Inc.
    Additional Material: 15 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 45
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 34 (1997), S. 29-37 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: The objective of this study was to evaluate the effects of metal ions, which may be released from orthopedic or dental implants, on osteoblast metabolism and differentiation. ROS 17/2.8 cells were cultured in F-12 medium for 7 days. Then Al+3, Co+2, Cr+3, Ni+2, Ti+4, and V+3 were added at concentrations less than their cytotoxic concentrations. After 3 days, DNA synthesis, succinate dehydrogenase activity, alkaline phosphatase (ALP) activity, and culture calcification were assessed. Northern blots were performed for ALP, osteocalcin (OCN), and osteopontin (OPN) mRNA transcription. The data indicated that Cr+3 and Al+3 had few inhibitory effects on ROS cell metabolism below their cytotoxic concentrations, Ni+2, Co+2, Ti+4, and V+3 affected all these parameters of ROS cell metabolism at concentrations below cytotoxic levels. For RNA analysis, Al+3 significantly suppressed the expression of ALP, OCN, and OPN at both cytotoxic and noncytoxic concentrations. Co+2 specifically suppressed ALP expression at cytotoxic concentrations. Cr+3 and Ni+2 inhibited OCN, OPN, and ALP gene expression only at cytotoxic concentrations. For Ti+4 and V+3 ions, gene expression at cytotoxic levels was not significantly affected as compared with the effects at noncytotoxic level. These results show that metal ions may alter osteoblast behavior even at subtoxic concentrations, but do not always affect the expression of all genes similarly. © 1997 John Wiley & Sons, Inc.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 46
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 34 (1997), S. 73-78 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: The present study analyzes the kinetics of the in vivo degradation of hydrophilic Mitrathane® in the peritoneal cavity of mice over a period ranging from 1 to 180 days. The mechanical milling of the polyurethane films produced regularly flattened fragments that in vivo spontaneously oriented into piles. The morphological observations and analysis with the aid of an image analysis system demonstrated that after seven days of swelling the polymer fragments undergo a continuous degradation that leads to an irregular thinning and phagocytosis of the smaller fragments by macrophages with very little chronic inflammation response from surrounding tissues. © 1997 John Wiley & Sons, Inc.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 47
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 34 (1997), S. 95-104 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: A biodegradable polyphosphate polymer (Mn = 18,000, Mw/Mn = 3.2) matrix system was developed as a potential delivery vehicle for growth factors. As a model system, release of recombinant human osteogenic protein-1 (OP-1) from this polymer was evaluated. The polyphosphate was synthesized using a triethylamine catalyst in an argon environment, and characterized using elemental analysis, gel permeation chromatography (GPC), and Fourier transform infrared spectroscopy (FTIR). Degradation kinetics of the polyphosphate polymer in phosphate-buffered saline (PBS) were represented by a second-order polynomial while degradation in bovine serum was linear with time. The polymer degraded faster in PBS than in bovine serum. In vitro release of OP-1 was also faster in PBS than in serum. Release kinetics of OP-1 in PBS and serum were represented by second-order polynomials. The OP-1 release from this physically dispersed polymeric matrix may be described by several possible mechanisms: diffusion, bulk polymer degradation, ion complexation, and interactions among the protein (OP-1), polymer, proteins, and enzymes in the media. This polyphosphate may be an effective carrier for morphogens, growth factors, or other classes of bioactive molecules. © 1997 John Wiley & Sons, Inc.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 48
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: The applicability of bioactive glass (BG) granules as a substitute for bone grafts was tested by comparing the histologic, histomorphometric, and molecular biologic healing patterns to those of bone autografts and ungrafted bone defects in a rat model. The cellular response in defects filled with BG granules was characterized by continuous overexpression of type III collagen. Osteogenic mesenchymal cells, prior to their differentiation to osteoblasts, organized as a dense periosteumlike layer on the surface of the BG granules. By day 14 new bone formation was more extensive in autografted defects than in BG filled defects (p = 0.039). No cartilage-specific type II collagen mRNA was detectable, confirming the uniformity of intramembranous bone formation. The difference in the initiation of new bone formation was further confirmed by the mRNA analyses of the de novo production of TGF-β1 and type I collagen. Autografted defects demonstrated the highest levels of TGF-β1 and type I collagen mRNAs during the first 2 weeks of healing, whereas BG-filled defects showed biphasic expression patterns of the same genes. Spontaneous new bone formation in ungrafted bone defects was also characterized by biphasic expression of type I collagen gene. Osteonectin mRNA declined gradually over time in autografted and BG filled defects, whereas unfilled defects showed a gradual increase of osteonectin mRNA during healing. By 8 weeks, about 70% of the BG surface showed evidence of direct new bone contact. Energy-dispersing X-ray analyses confirmed the presence of silica-rich and CaP-rich zones at the bonding interface. In conclusion, the osteoconductive surface of bioactive glass granules efficiently bonds to ongrowing new bone but the material does not reach the capacity of autogenous bone graft in promotion of osteogenesis. © 1997 John Wiley & Sons, Inc.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 49
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 35 (1997), S. 75-80 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: The dynamics for the hydraulic process of calcium phosphate cement (CPC) were investigated by X-ray diffraction quantitative analysis. The results show that the hardening process of CPC is initially controlled by the dissolution of reactants in a 4-h period and subsequently by diffusion through the product layer of hydroxyapatite (HAP) around the grains. The compressive strength rises approximately linearly with the increase of the extent of conversion in a 4-h period, and a maximum compressive strength of about 51 MPa, which is superior to those reported by the references, is obtained in 4 h. Then the compressive strength drops a little with an increase in the extent of conversion. The final product of setting reaction is acicular HAP crystal. Crystal seed not only reduces the setting time but also drops the compressive strength. The variation of pH in CPC slurry from 7.5 to 10.5 reveals that the control step of the dissolution process in the hardening process is the dissolution of dicalcium phosphate anhydrous and the presence of crystal seed will reduce the supersaturation to produce HAP. © 1997 John Wiley & Sons, Inc.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 50
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 35 (1997), S. 81-92 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: The temporal deposition of selected complement proteins from human serum onto immobilized human colostrum immunoglobulin (Ig)A and human IgG on hydrophobic silicon was studied by ellipsometry-antibody techniques after incubations at 37°C for up to 1 h. In parallel experiments the serum soluble iC3b, C4d, and Bb were detected by enzyme-linked immunosorbent assay techniques. The IgA-coated surfaces showed activation via the alternative pathway, and displayed a lag phase in the deposition of increased amounts of serum proteins, and anti-C3c and antiproperdin. Anti-IgG, -C1q, -C4, -factor H, and -factor B were not deposited at any time to IgA surfaces. Upon coating of the surface with IgG, the classical pathway was rapidly activated and bound, then anti-C3c, antiproperdin, and after short serum incubation times, also anti-C1q and anti-IgG. When factor B-depleted or heat-treated sera were used, the observation was that properdin deposited onto IgG-coated surfaces from both. Ellipsometry and antibody techniques offer a convenient and rapid way to indicate the activation of the complement system on solid surfaces and facilitates a time-resolved determination of the activation pathway(s). © 1997 John Wiley & Sons, Inc.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 51
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: The purpose of this study was to compare the effect of polymer foam morphology and density prior to compaction on the kinetics of isoniazid (INH) release from the final high-density extruded matrices. The feasibility of preparing low density foams of several biopolymers, including poly(L-lactide) (PLLA), poly(glycolide) (PGA), poly(DL-lactide-co-glycolide) (PLGA), poly(γ-benzyl-L-glutamate) (PBLG), and poly(propylene fumarate) (PPF), via a lyophilization technique was investigated. Low-density foams of PLGA, PBLG, and a mixture of PLGA and PPF were successfully fabricated by lyophilization of the frozen polymer solutions either in glacial acetic acid or in benzene. The morphology of these foams depends on the polymer as well as the solvent used in the fabrication process. Thus, PLGA produces a capillary structure when lyophilized from benzene solution and a leaflet structure from glacial acetic acid, but PBLG yields a leaflet structure from benzene. Matrices were prepared by impregnating these foams with aqueous solutions of INH, removing the water by a second lyophilization, and then compressing the low-density INH containing foams by compaction and high-pressure extrusion. The resulting nonporous matrices had densities of approximately 1.30 g/cm3. In vitro kinetics were in accord with the Roseman-Higuchi diffusion model and demonstrate that release rates depend on the initial foam density, while foam structure has little influence on the release kinetics. © 1997 John Wiley & Sons, Inc.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 52
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 35 (1997), S. 137-145 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Collagen-based implants have been described as vehicles for transplantation of cultured skin cells for treatment of burn wounds. To optimize vascularization and repair of connective tissue, collagen solubility and glutaraldehyde crosslinking were evaluated. Cultured skin substitutes consisted of human keratinocytes and fibroblasts attached to collagen-glycosaminoglycan substrates that were prepared from acid-insoluble, or partially soluble collagen. Substrates were crosslinked with 0% or 0.25% glutaraldehyde, populated with cells, and grafted to full-thickness wounds on athymic mice (n = 6/condition). After 6 weeks, the wound area was measured by planimetry, and healed wounds were scored by histochemistry for immunoreactivity to HLA-ABC and bovine collagen. Data analysis shows that crosslinking of collagen implants with glutaraldehyde is associated (p 〈 0.001) with detection of the implant. No association was found between solubility of bovine collagen and immuno-detection. Epidermis of all wounds was positive for HLA-ABC, and no differences in wound areas were found. These results suggest that glutaraldehyde crosslinking of collagen implants decreases the rate of biodegradation. Delayed degradation of crosslinked collagen may result clinically in reduced engraftment of skin substitutes. © 1997 John Wiley & Sons, Inc.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 53
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 35 (1997), S. 175-180 
    ISSN: 0021-9304
    Keywords: styrene-butadiene-styrene triblock copolymer ; dimethyl amino ethyl methacrylate ; graft copolymer ; biomaterial ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: A styrene-butadiene-styrene triblock copolymer (SBS) membrane was prepared by solvent casting. Grafting of dimethyl amino ethyl methacrylate (DMAEMA) to this SBS membrane was subsequently conducted by ultraviolet radiation-induced graft copolymerization without degassing to obtain a SBS-g-DMAEMA copolymer membrane. The graft copolymer was characterized by infrared spectroscopy and scanning electron microscopy. The degree of grafting and the mechanical properties of SBS and SBS-g-DMAEMA were measured. Contact angle, water content, and protein absorption of fibrinogen and albumin experiments were also performed to evaluate the biocompatibility of SBS-g-DMAEMA graft copolymer membranes. It was found that the degree of grafting was related to the irradiation time, DMAEMA concentration, and temperature. The tensile strength of the SBS-g-DMAEMA membrane increased with an increase in the degree of grafting. By using Kaelble's equation and the contact angle data, the surface tension of SBS-g-DMAEMA was determined. It was found that with an increase in the degree of grafting, the surface tension and water content of SBS-g-DMAEMA membrane increased, whereas the contact angle decreased. The amount of absorption of albumin and fibrinogen decreased with an increase in amount of grafting. However, there was a minimum for the adsorption of proteins in the SBS-g-DMAEMA membrane. © 1997 John Wiley & Sons, Inc. J Biomed Mater Res, 35, 175-180, 1997.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 54
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 35 (1997), S. 207-216 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: In vitro cyclic load fretting tests were conducted on a prototype of a cementless, modular neck, hip prosthesis. The study had three major objectives: to determine the amount of fretted material in the tapered-neck joint under various load cycle amplitudes, to determine the fretting damage evolution, and to determine the effect of different-sized stem bodies on the production of debris. All the tests produced some fretting microdamage on the tapered surface although the extent was quite different among test groups. The amount of abraded material increased almost linearly with the applied load magnitude but not with the number of load cycles. The amount of weight loss was higher in the large stem bodies than in the small ones. Weight loss ranged from 0.28 ± 0.10 mg for small stem bodies loaded 5.5 million times up to 2300N to 2.54 ± 0.53 mg for large stem bodies located 20 million times up to 3300N. Considering the large-size stem results, and assuming one million load cycles between 300N and 3300N to be the average yearly load history, the modular neck tapered joint would produce 0.6 mg/year of metal debris. The clinical impact of this observation is unknown; however, some of the literature on the presence of metal in patient tissues and fluids supports the hypothesis that a normal and stable prosthesis is likely to produce less than 10 mg/year of metal debris. Thus, a further production of 0.6 mg/year due to the modular neck should not have any significant effect. © 1997 John Wiley & Sons, Inc.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 55
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 35 (1997), S. 265-271 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: To determine if metal ions play a contributing role in loosening of orthopedic implants, the present work investigated whether sublethal concentrations of ions affect the formation and function of osteoclasts in vitro. Rat bone marrow cells were cultured on slices of devitalized bone and in the presence of ions associated with Co-Cr-Mo and Ti-6Al-4V alloys for up to four weeks. Cultures were assayed for total intracellular protein, used as measure of cell growth, and resorption activity of osteoclastic cells derived from hematopoietic stem cells was quantified using image analysis. Although Co2+ caused delayed toxicity not previously observed during short-term experiments, none of the other ions affected cell proliferation, indicating that the chosen concentrations were sublethal. In general, exposure of bone marrow cultures to ions caused either a decrease or no change in the total area of bone resorption. A decrease in the number of resorption pits formed by osteoclastic cells was primarily responsible for the decrease in total amount of resorption. Therefore, even though cells continued to grow over the entire culture period, less osteoclastic activity was observed. Findings indicate that if metal ions play a role in periprosthetic pathology, they may contribute to implant failure by impairing bone repair while allowing fibrous tissue formation following debris-induced osteolysis. © 1997 John Wiley & Sons, Inc.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 56
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 35 (1997), S. 299-308 
    ISSN: 0021-9304
    Keywords: nucleation ; kinetics ; growth ; microscopy ; solution chemistry ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: The kinetics of stoichiometric (Ca/P = 1.67) and calcium-deficient (Ca/P = 1.5) hydroxyapatite formed in aqueous solution by acid-base reactions involving CaHPO4 and Ca4(PO4)2O were determined. Complete reaction occurs within 6 h at 37.4°C regardless of composition with stoichiometric hydroxyapatite forming more rapidly. Stoichiometric hydroxyapatite formed more rapidly because the particle sizes of its precursors were smaller. Hydroxyapatite formation is characterized by an initial period of surface hydration of the precursors, an induction period, and a period during which the bulk of the conversion to hydroxyapatite occurs. During the first 3 h of reaction at 37.4°C the pH is about 8.25 and 7.6, respectively, as the stoichiometric and calcium-deficient hydroxyapatite are being formed. Subsequently the pH values move toward those of the related invariant points: Ca10(PO4)6(OH)2-CA(OH)2 solution, and CaHPO4-Ca9HPO4(PO4)5OH solution. The concentrations of calcium and phosphate in solution never exceed those in serum. Seeding with 5 wt % hydroxyapatite eliminates induction regardless of composition. The kinetics are first-order and follow the Arrhenius relationship regardless of composition. The total heats of reaction (ΔHt) were determined at constant temperatures between 25°C and 70°C. ΔHt values of 261.3 and 320 kJ/mol were determined for the formation of calcium-deficient hydroxyapatite and stoichiometric hydroxyapatite, respectively. Activation energies of 84.5 and 87.4 kJ/mol were calculated for the formation of calcium-deficient and stoichiometric hydroxyapatite, respectively. Heats of formation for Ca4(PO4)2O and Ca9HPO4(PO4)5OH were calculated to be -4764.1 and -12707.7 kJ/mol, respectively. © 1997 John Wiley & Sons, Inc. J Biomed Mater Res, 35, 299-308, 1997.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 57
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 35 (1997), S. 329-336 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Detailed friction load-displacement response of four distinct metallic surfaces [one beaded porous metal (CTR) and three cast Co-Cr alloy ingrowth mesh surfaces, nonplanar mesh (INX), cast mesh 1 (CM1), and cash mesh 2 (CM2)] on polyurethane and cancellous bone specimens of six tibiae were measured under different normal stresses (0.1, 0.15, or 0.025 MPa). Bone cubes were obtained from different proximal regions of resurfaced cadaveric tibiae. Both monotonic and cyclic fatigue loadings of up to 4000 cycles at 1 Hz were considered. Comparison of measured results indicated that the friction coefficient was not affected by the magnitude of normal stress and the bone excision site (medial, lateral, anterior, posterior, and central). The CM2 surface showed significantly greater resistance with friction coefficients of more than 0.9 for the bone and 0.8 for the polyurethane. The INX surface yielded the second largest resistance followed by CMI and CTR surfaces. No significant difference was found between these latter two surfaces. Fatigue tests up to 4000 loading-unloading cycles showed about 10% reduction in friction coefficient for CTR and INX surfaces, while negligible reduction was found for CM1 and CM2 surfaces. © 1997 John Wiley & Sons, Inc.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 58
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 35 (1997), S. 337-347 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: HA-ceramics used in human surgery as osteoconductive surfaces show a great variety of characteristics. Certain characteristics such as grain size, porosity, and surface area, are controlled by the sintering temperature of the slurry. We grew L-929 fibroblast cells on HA-ceramic disks that had been sintered at different temperatures ranging from 850°-1350°C. The cell line growth rate was lower on ceramic disks than on the culture-grade polystyrene used as a negative control. Cell growth correlated with the ceramic sintering temperature although no significant difference in the cell adhesion to the different ceramics was shown. Growth rate on ceramics sintered at low temperatures (850° and 950°C) was negative whereas it was positive on disks sintered at higher temperatures. When the cells were separated from the disks by a polycarbonate membrane, the growth rate was negative on those membranes in contact with low-temperature sintered disks and positive on the high-temperature sintered disks. The calcium and phosphorus concentration in the culture medium in contact with ceramics sintered below 1050°C decreased during the culture period. Ceramics sintered between 1100° and 1250°C brought about an increase in Ca and P concentrations while ceramics sintered at higher temperatures did not induce any changes. SEM examination of the 850° and 1200°C sintered ceramics showed that the 850°C sintered ceramics consisted of small grains with pores between them and the 1200°C sintered ceramics were made of larger grains without any visible pores, thereby decreasing the surface of material in contact with the culture medium. This difference in surface area was confirmed by the fact that the amount of albumin adsorbed onto the ceramic was dependent on the sintering temperature. In conclusion, the modification of the culture medium brought about by high-surfaced ceramics could influence the growth of cells with which such ceramics come in contact. © 1997 John Wiley & Sons, Inc.
    Additional Material: 10 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 59
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Tumor promotion activity of polyethylene (PE) was estimated in terms of the inhibitory potentials on the gap-junctional intercellular communication using the metabolic cooperation assay. The gap-junctional intercellular communication of test cells was inhibited on the PE film, but this inhibitory activity was markedly decreased when the surface of the PE film was immobilized with collagen. These results suggest that the in vivo tumor promotion activity of the untreated PE may be stronger than that of collagen-immobilized PE. On the other hand, surface modification with RGDS peptide, which is well knownn as the sequence of cell attachment domain in extracellular matrix proteins, did not reduce the promotion activity of PE film. In addition, neither modification with bovine serum albumin nor RGES peptide reduced the activity of PE film. These findings suggest that reduction of the inhibitory activity on gap-junctional intercellular communication of collagen immobilization is not simply due to improved cell adherence via the RGDS sequence but to some cell-cell recognition via collagen molecules essential for the gap-junctional intercellular communication. © 1997 John Wiley & Sons, Inc.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 60
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 35 (1997), S. 443-450 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Cuprophan hemodialysis membranes can be heparinized using N,N′-carbonyldiimidazole (CDI) as a coupling agent. In this study, the characteristics of heparinized Cuprophan membranes have been evaluated. After immobilization, heparin partially retained its biologic activity. An anticoagulant activity of 12.4 ± 4.2 mU/cm2 was measured using a thrombin inactivation assay. Immobilized heparin also displayed an anti-complement activity. After contact with human serum, heparinized Cuprophan induced no generation of significant amounts of fluid phase terminal complement complex (TCC), whereas untreated Cuprophan induced the generation of substantial amounts of TCC. Heparinization did not affect the permeability of Cuprophan for model solutes with molecular weights up to 12,000 g/mol except for sulfobromophthalein sodium salt. The permeability of Cuprophan for sulfobromophthalein sodium salt was slightly decreased after heparinization. The ultrafiltration rate of Cuprophan increased by about 30% after heparinization, probably owing to an increased swelling of the membrane in water. Heparinized Cuprophan incubated in phosphate-buffered saline at 37°C showed some release of heparin. These amounts of released heparin, however, were very low as compared to the amounts of heparin which are systemically administered during clinical hemodialysis treatment. It is concluded that Cuprophan membranes heparinized by means of the CDI-activation procedure are highly promising for application in hemodialyzers to be used for the treatment of patients with reduced or without systemic administration of heparin. © 1997 John Wiley & Sons, Inc.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 61
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 35 (1997), S. 497-503 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: The most important reactive groups in collagen are amino, amido, guanidino, and carboxyl, all of which are present in comparatively large numbers. It is possible to modify amide groups present in the collagen of achilles tendons and hide trimmings by desamidation (DAM). DAM causes progressive hydrolysis of the amide groups of asparagine and glutamine side chains of collagen, thereby resulting in the reduction of the amide content of collagen. Loss of amide brings about an increase in the number of free carboxyl groups in the desamidated collagen, shown by reduction in its isoionic pH. The new modified collagen, like type I bovine collagen, has high viscosity and high hydroxyproline content. The fibril formation of the modified collagen showed slight variation, and polyacrylamide gel electrophoretic analysis indicated largely alpha components, indicating destruction of inter- and intramolecular crosslinks. The swelling behavior of the modified collagen is significantly higher compared to type I bovine collagen. © 1997 John Wiley & Sons, Inc.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 62
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: The design of biomaterials containing specific ligands on the surface offers the possibility of creating materials that can interact with and potentially control mammalian cell behavior. Biodegradable materials further provide the significant advantage that the polymer will disappear in vivo, obviating long-term negative tissue responses as well as the need for retrieval. In earlier studies we synthesized and characterized arginine - glycine - aspartic acid (RGD) peptide-modified poly(lactic acid-co-lysine) (PLAL). In this study, both bulk properties and surface features have been characterized, with a focus on surface analysis as a means of interpreting observed changes in cell behavior. Bulk peptide attachments were performed using 1,1′-carbonyldiimidazole (CDI). Amino groups were measured using colorimetric assays and X-ray photoelectron spectroscopy (XPS). Peptides were measured by incorporating iodine into the peptide as a distinct elemental marker for use with XPS. Typical samples contained 13 ± 4 pmol/cm2 of amino groups and 4 ± 0.2 pmol/cm2 of peptides, as calculated from XPS measurements of nitrogen and iodine. The wettability and crystallinity of the samples were determined by contact angles and differential scanning calorimetry, respectively. Wettability and crystallinity were not altered by the incorporation of lysine or peptides. After incubating bovine aortic endothelial (BAE) cells for 4 h on surfaces with RGD-containing peptides, the mean spread cell area increased from 77 ± 2 μm2 to 405 ± 29 μm2 compared to 116 ± 11 μm2 on poly(lactic acid), 87 ± 4 μm2 on PLAL, and 105 ± 4 μm2 on surfaces with RDG-containing (control) peptides. The significance of this work is that the first synthetic interactive, resorbable biomaterial has been developed, and use of this material to control cell behavior has been demonstrated. © 1997 John Wiley & Sons, Inc.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 63
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 36 (1997), S. 29-37 
    ISSN: 0021-9304
    Keywords: plasma treatment ; integrin ; epithelial cells ; synthetic cornea ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: We have demonstrated that the optimal surface treatment of a polyvinylalcoholcopolymer hydrogel for epithelial cell migration and proliferation is an argon radio frequency (rf) plasma treatment. The surface chemistry of the material was determined prior to each cellular evaluation, allowing us to compare the biological response with a known surface chemistry. The cellular response was carried out in a consistent manner a minimum of three separate runs. We found that the optimal conditions required culturing the cells under constant rotation. Cells became confluent on argon-plasma-treated surfaces coated under several different reaction pressures, and after 2 weeks they became multilayered. Our experiments demonstrated that cells proliferated and extracellular matrix and adhesion proteins were present only when the surface was treated with an argon rf plasma; acetone- and ammonia-treated surfaces did not yield the desired results. Organ culture experiments further demonstrated the efficacy of the argon-treated surfaces. In these experiments, intact keratoprosthetic devices with modified hydrogel surfaces were implanted into rabbit corneas. The excised corneas containing the devices were cultured, and 3 weeks later, using confocal laser scanning microscopy, confluent epithelium was detected on the modified hydrogel surface. This is the first demonstration that rabbit limbal epithelial cells can migrate onto a synthetic cornea containing a modified hydrogel-treated surface and form a confluent surface of epithelium. © 1997 John Wiley & Sons, Inc. J Biomed Mater Res, 36, 29-37, 1997.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 64
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Microporous polymers have great potential for the production of corneal keratoprosthetic devices. Keratocytes invade the pores of expanded polytetrafluoroethylene implants (ePTFE) and collagen synthesis occurs. This ePTFE becomes translucent after its implantation in the stroma of rabbit cornea. The rate and density of cell growth within this polymer depends on the implant thickness, pore size, and its placement in the cornea. We have investigated the influence of the polymer permeability on the collagen and protein contents of ePTFE implants. Rabbit corneal stroma were implanted with ePTFE disks (6 mm in diameter) by intralamellar keratoplasty. The implanted polymers were removed from the stroma after 3 or 6 months. The collagen and protein contents were determined after pepsin solubilization. The collagen content of the high-permeability implant was 3.7-fold greater than that of the low-permeability implant 3 months after implantation and 2.4-fold greater after 6 months. The total protein content of the high-permeability implant was 2.5-fold greater than that of the low-permeability implant at 3 months and was the same after 6 months. The collagen-to-protein ratio was 68% in the high-permeability implants, and thus similar to that of normal corneal stroma. Thus, high polymer permeability increased both the rate and density of the corneal extracellular matrix ingrowth. © 1997 John Wiley & Sons, Inc.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 65
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 35 (1997), S. 349-356 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: In the quest for hydrogel contact lenses with improved extended wear capability, the use of siloxane moieties in the lens materials was investigated. However, the introduction of hydrophobic siloxane groups gave rise to wettability and lipidlike deposit problems. It was found that when polysiloxane-based compositions for hydrogels were processed with polar plastic molds, such as those fabricated from an acrylonitrile-based polymer, the hydrogel lenses fabricated were wettable, with minimized lipidlike deposits. These findings were supported by the wettability of silicone hydrogel films, silicon, and nitrogen element contents near lens surfaces, as well as the results from clinical assessment of silicone hydrogel lenses. © 1997 John Wiley & Sons, Inc. J Biomed Mater Res, 35, 349-356, 1997.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 66
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 35 (1997), S. 371-381 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Polyurethanes are widely used as biomaterials for medical implants because of their excellent mechanical properties and moderate biocompatibility. However, the demand for more bioresistant and biocompatible polyurethanes to meet the needs of long-term implant devices still remains an important issue. Since most biological interactions with materials occur at the interface, a significant number of studies for improving the biocompatibility of polyurethanes have concentrated on surface modification. It is well known that additives used in polymeric materials as processing aids, mold releasing agents, antioxidants, etc., migrate to the surface and change the surface properties of the material. Under certain conditions polymeric additives may also migrate toward surfaces. This study describes two fluorine-containing, surface-modifying macromolecules (SMMs) that have been evaluated for their ability to inhibit polyurethane degradation. These materials actively migrate to the upper surface of a material film when they are mixed with a base polymeric material. Contact angle measurements for the mixture of SMM with base polyurethane indicate that the surface becomes more hydrophobic after adding the SMMs, while X-ray photoelectron spectroscopy analysis shows an enrichment of fluorine on the polymer surfaces. Differential scanning calorimetry thermograms indicate that the microstructure, as defined by the thermal transitions of the base polymer, are not altered by the addition of SMMs. Enzyme-induced biodegradation tests exhibit a significant reduction of polyurethane degradation in the presence of these surface-resident materials. The results indicate that the SMMs have the potential to resist hydrolytic degradation mediated by lysosomal enzymes while generating a surface chemistry on the native elastomer which is similar in nature to that of a fluoropolymer, e.g., Teflon. © 1997 John Wiley & Sons, Inc.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 67
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 36 (1997), S. 109-117 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Viscosity-temperature dependence has been investigated for glasses in a system where bioactive compositions are found. A glass is called bioactive when living bone can bond to it. In this work, high-temperature microscopy was used to determine viscosity-temperature behavior for 40 glasses in the system Na2O-K2O-MgO-CaO-B2O3-P2O5-SiO2. The silica content in the glasses was 39-70 wt %. All glasses containing 〈54 mol % SiO2 devitrified during the viscosity measurements. Generally, glasses that devitrified contained more alkali but less alkaline earths than glasses with a large working range. A working range is the temperature interval at which forming of a glass can take place. This temperature interval can, for bioactive glasses, be enlarged by decreasing the amount of alkali, especially Na2O, in the glass and by increasing the amount of alkaline earths, especially MgO. Optionally, B2O3 and P2O5 can be added to the glass. An enlarged working range is a prerequisite for an expanded medical use of bioactive glasses as, e.g., sintered and blown products, and fibers. © 1997 John Wiley & Sons, Inc.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 68
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 36 (1997), S. 131-136 
    ISSN: 0021-9304
    Keywords: titanium ; calcium ion implantation ; rat tibia ; fluorescence microscope ; bone formation ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Rat tibia tissue into which calcium ion (Ca2+)-implanted titanium was surgically placed was histologically analyzed to investigate the performance of the Ca2+-implanted titanium as a biomaterial. Calcium ions were implanted into only one side of titanium plates at 1017 ions/cm2 and the Ca2+-treated titanium was surgically implanted into rat tibia for 2, 8, and 18 days. Tetracycline and calcein were used as hard-tissue labels. After excision of the tibia, the tissues were fixed, stained, embedded in polymethyl methacrylate, and sliced. The specimens were observed using a fluorescence microscope. A larger amount of new bone was formed on the Ca2+-treated side than on the untreated side, even at 2 days after surgery. In addition, part of the bone made contact with the Ca2+-treated surface. On the other hand, bone formation on the untreated side was delayed and the bone did not make contact with the surface. Mature bone with bone marrow formed in 8 days. Neither macrophage nor inflammatory cell infiltration was observed. The results indicated that Ca2+-implanted titanium is superior to titanium alone for bone conduction. © 1997 John Wiley & Sons, Inc. J Biomed Mater Res, 36, 131-136, 1997.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 69
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 36 (1997), S. 167-180 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: We describe the effects on cell function of treating porous bioactive glass (BG) such that its surface is a composite of carbonated hydroxyapatite and serum protein. The effects on bone cell function of porous hydroxyapatite (HA) ceramic and porous glass treated to become amorphous calcium phosphate only also were studied subsequent to their having adsorbed a serum protein layer. Substrates treated for different durations were seeded with MC3T3-E1 cells and cultured for 3-17 days. Whereas cells seeded on any substrates, BG and HA produced collagen types I and III, bone sialoprotein, and osteopontin, there were significant differences between HA and BG, and among the various surface conditions created on BG. Covering the glass surface with hydroxyapatite and serum protein enhanced expression of high alkaline phosphatase activity, high rates of cell proliferation, and production of mineralized extracellular matrix. The enhancement may be due to the adsorption of a high quantity of fibronectin from the serum onto the reacted bioactive glass surface. © 1997 John Wiley & Sons, Inc.
    Additional Material: 16 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 70
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 36 (1997), S. 209-215 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: The development of a zero net shrinkage dental restorative material based upon a polymer-bioactive glass composite requires a second-phase material that expands. This study details the mechanisms of silica ring expansion by reaction with carbon monoxide. Carbon monoxide was used as a model adduct to represent potentially active sites on the polymer phase of the dental restorative. Silica rings were used to model the bioactive-glass phase of the composite. The 3-, 4-, 5-, and 6-“member” silica rings have been modeled using the Austin Method (AM1) semi-empirical molecular orbital calculations. The reaction pathways were determined for carbon monoxide (CO) reaction addition to each of the rings. The activation barriers (Ea) for the ring expansions were determined from the transition state geometries wherein only one imaginary eigenvalue in the vibration spectrum existed (a true saddle point). In each case the reaction pathway included the hydrogen bonding of CO with a silicon, exothermic pentacoordinate bonding to silicon by the CO and weakening of the Si-O bridging bonds of the ring, and, finally, the incorporation of CO into the ring, forming a silica-carbonate ring. The activation for the ring expansions are +4.3, +6.1, +7.0, and -2.9 Kcal/mol for 3-, 4-, 5-, and 6-“member” silica rings, respectively. The volumetric expansion of the silica was estimated based upon the dilation of adjacent silicon-silicon atomic distances. The dimensional change was calculated to be 3.9%, 21.3%, 19.4%, and 24.2% for 3-, 4-, 5-, and 6-membered silica-carbonate rings, respectively. © 1997 John Wiley & Sons, Inc.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 71
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 36 (1997), S. 223-232 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Previous studies have shown that both polyester and polyether-based polyurea-urethanes are susceptible to cleavage by hydrolytic enzymes. Furthermore, it has been hypothesized that the degree of hard segment micro-domain formation in polyurethane materials, as well as its structure, influences the ability of enzymes to degrade the polymers. The current study has investigated a series of segmented polyether-urea-urethanes synthesized with the same reagents but having different hard segment content. Using these materials, the relationship between the formation of hard segment domains and the hydrolysis of urea/urethane groups was specifically addressed. Both differential scanning calorimetry and X-ray photo-electron spectroscopy data indicated that the three materials differed significantly in the extent of hard segment domain formation and the nature of the chemical groups located in the top 10 nm of the surface. Biodegradation studies showed a strong dependence on hard segment domain formation and indicated that the polymer containing the highest number of hydrolytically labile urea and urethane bonds exhibited the least degradation. The ability of a polyurethane material to form hard segment micro-domains may contribute to the formation of a protective structure for the hydrolysable hard segment linkages located within the micro-domains. © 1997 John Wiley & Sons, Inc.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 72
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Calcification of glutaraldehyde-preserved bioprosthetic heart valves (BHVs) results in their clinical failure. The mechanism of this pathologic calcification is not well defined. Since serum proteins are known to be taken up in mineralized tissue, we hypothesized that serum proteins derived from several calcium-binding noncollagenous proteins (NCPs) of bone and teeth also may be associated with pathologically mineralized BHVs. Using a rat subdermal model of BHV calcification, glutaraldehyde-preserved bovine pericardium (GPBP) was implanted for 1, 3, 14, and 60 days, and then subjected to an extraction procedure designed to isolate only NCPs tightly bound to the mineral phase. Gel electrophoresis and Coomassie Brilliant Blue staining demonstrated that these proteins became associated with GPBP over time, paralleling reported calcium uptake by the tissue. Stains-All staining demonstrated a marked accumulation of highly acidic, phosphorylated NCPs associated with 60-day GPBP extracts. Some of these proteins were detected in rat serum but were absent from extracts of GPBP incubated in rat serum in vitro. Western blotting with antibodies to three NCPs found in bone and teeth - bone acidic glycoprotein 75 (BAG 75), osteopontin, and SPARC - demonstrated that these NCPs were tightly bound to the mineral phase of calcified GPBP. A fourth NCP, bone sialoprotein II (BSP II) was barely detectable. Thus each identified NCP showed a different pattern of GPBP association relative to mineral deposition, suggesting unique roles for each in pathologic calcification. SPARC increased within 3 days of GPBP implantation but decreased by 2 weeks. BAG 75 and osteopontin uptake was detected in the initial mineral deposits and increased mineralization proceeded. BSP II never increased significantly over the entire period. Further studies, which should include immunohistochemistry, will be important for delineating the source, location, and function of these three NCPs and for identifying others that also may be involved in this pathological process. Most important, the new insights into the mechanism of pathologic calcification described here present exciting opportunities for novel approaches to BHV calcification prevention. © 1997 John Wiley & Sons, Inc.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 73
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: We fabricated poly(DL-lactic-co-glycolic acid) (PLGA) 50:50 microparticles loaded with an antisense (AS) oligodeoxynucleotide (ODN) against the rat tenascin mRNA and determined the effect in vitro of the AS-ODN released on smooth muscle cell (SMC) proliferation and migration. AS-ODN was entrapped using a double-emulsion-solvent-extraction technique with high efficiency. Release of AS-ODN was characterized by a small initial-burst effect followed by a period of controlled AS-ODN release for up to 20 days. SMC proliferation studies exhibited dose-dependent growth inhibition with AS-ODN-loaded microparticles. Microparticles loaded with scrambled (SC) ODN showed less growth inhibition than AS-ODN. Moreover, only the AS-ODN-loaded microparticles inhibited migration. These results demonstrate the feasibility of entrapping an AS-ODN to rat tenascin in PLGA microparticles for controlled delivery to inhibit SMC proliferation and migration. © 1997 John Wiley & Sons, Inc.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 74
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Bone formation was investigated in vitro by culturing stromal osteoblasts in three-dimensional (3-D), biodegradable poly(DL-lactic-co-glycolic acid) foams. Three polymer foam pore sizes, ranging from 150-300, 300-500, and 500-710 μm, and two different cell seeding densities, 6.83 × 105 cells/cm2 and 22.1 × 105 cells/cm2, were examined over a 56-day culture period. The polymer foams supported the proliferation of seeded osteoblasts as well as their differentiated function, as demonstrated by high alkaline phosphatase activity and deposition of a mineralized matrix by the cells. Cell number, alkaline phosphatase activity, and mineral deposition increased significantly over time for all the polymer foams. Osteoblast foam constructs created by seeding 6.83 × 105 cells/cm2 on foams with 300-500 μm pores resulted in a cell density of 4.63 × 105 cells/cm2 after 1 day in culture; they had alkaline phosphatase activities of 4.28 × 10-7 and 2.91 × 10-6 μmol/cell/min on Days 7 and 28, respectively; and they had a cell density that increased to 18.7 × 105 cells/cm2 by Day 56. For the same constructs, the mineralized matrix reached a maximum penetration depth of 240 μm from the top surface of the foam and a value of 0.083 mm for mineralized tissue volume per unit of cross sectional area. Seeding density was an important parameter for the constructs, but pore size over the range tested did not affect cell proliferation or function. This study suggests the feasibility of using poly(α-hydroxy ester) foams as scaffolding materials for the transplantation of autogenous osteoblasts to regenerate bone tissue. © 1997 John Wiley & Sons, Inc.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 75
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 36 (1997), S. 306-314 
    ISSN: 0021-9304
    Keywords: magnesium ; hydroxyapatite ; calcium phosphate cement ; inhibition ; amorphous calcium phosphate ; nucleation and growth ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Calcium-deficient hydroxyapatite (HA) with a Ca/P molar ratio of 1.50 was synthesized in various concentrations (0.01-75 mM) of MgCl2 at 37.4°C by reaction between particulate CaHPO4 · 2H2O and Ca4(PO4)2O. The effects of magnesium on the kinetics of HA formation were determined using isothermal calorimetry. All reactions completely consumed the precursor phases as indicated by X-ray diffraction analysis and a constant enthalpy of reaction (240 kJ/mol). Magnesium concentrations below 1 mM had no effect on the kinetics of HA formation. Magnesium concentrations between 1 and 2.5 mM affected the reaction path but did not affect the time required for complete reaction. Higher concentrations extended the times of complete reaction due to magnesium adsorption on the precursor phase(s) and HA nuclei, and stabilization of a noncrystalline calcium phosphate (NCP). HA formation in the presence of magnesium resulted in separation of the following two events: initial formation of HA nuclei and NCP, and consumption of CaHPO4 · 2H2O. This was indicated by the appearance of an additional calorimetric peak. Variations in calcium, magnesium, and phosphate concentrations and pH with time were determined. Increasing the magnesium concentration resulted in elevated calcium concentrations. After an initial decrease in magnesium owing to its adsorption onto HA nuclei and precursor(s), a period of slow reaction at constant magnesium concentration was observed. Both the magnesium concentration in solution and the proportions of precursors present decreased prior to any evidence of a crystalline product phase. This is attributed to the formation of NCP capable of incorporating magnesium. This noncrystalline phase persisted for more than 1 year for reactions in magnesium concentrations about 2.5 mM. Its conversion to HA resulted in the release of magnesium to the solution. © 1997 John Wiley & Sons, Inc. J Biomed Mater Res., 36, 306-314, 1997.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 76
    ISSN: 0021-9304
    Keywords: poly(DL-lactide-ε-caprolactone) ; degradation ; foreign body reaction ; subcutaneous implant ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: The aim of this study was to evaluate the degradation and foreign-body reaction of poly(DL-lactide-ε-caprolactone) (PLA85CL50) bars. This specific biomaterial is used for the construction of nerve guides, which can be used in the reconstruction of short nerve gaps. Subcutaneously implanted PLA85CL50 bars were harvested after implantation periods ranging from 3 to 12 months and evaluated for the rate of degradation and the degree of foreign-body reaction. It was observed that this copolymer degraded completely within 12 months and that no lactide or ε-caprolactone crystals were formed. Furthermore, we conclude that the foreign-body reaction of PLA85CL50 is very mild. These properties make the amorphous copolymer of DL-lactide and ε-caprolactone (50:50) suitable for the construction of nerve guides. © 1997 John Wiley & Sons, Inc. J Biomed Mater Res, 36, 337-346, 1997.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 77
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 36 (1997), S. 91-97 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: To obtain further information on the interaction of hydroxyapatite (HA) and the bony implantation bed, 20- to 40-mesh dense HA particles were implanted into the tibiae of dogs. Following healing periods of 2 weeks, 1 month, and 3 months, the specimens were retrieved and prepared by either conventional preparatory procedures for scanning electron microscopy (SEM) or the EDTA-KOH method. Under SEM observation, the interparticular osteogenesis among HA particles progressed in a programmed sequence. Ample blood supply and osteoblasts initially presented in the interparticular space. The secretion of bone matrix resulted in the formation of immature bone. This scaffold was then transformed into mature lamellar bone during the following bone remodeling process. The serial changes closely resembled the pattern viewed in controls that did not implant HA. A spatial relationship between bone cells and HA was clearly demonstrated. In particular, the osteoblasts displayed an extremely flat appearance with many microappendages. The microappendages anchored cells to the HA surface and fused with granular material covering the HA crystals. The more characteristic cellular morphology was revealed by the EDTA-KOH method. Microscopic pictures clearly identified the three-dimensional images of ruffled borders of osteoclasts and the slender cytoplasmic processes of osteocytes. This study provided further evidence for the favorable biological response of HA to bone cells as well as the value of the EDTA-KOH method in examining the stereomorphology of bone cells. © 1997 John Wiley & Sons, Inc.
    Additional Material: 10 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 78
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 36 (1997), S. 99-108 
    ISSN: 0021-9304
    Keywords: biomaterial roughness ; surface free-energy ; cell adhesion ; organotypic culture ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Cell adhesion and spreading of chick embryo vascular and corneal explants grown on rough and smooth poly (methyl methacrylate) (PMMA) were analyzed to test the cell response specificity to substratum surface properties. Different degrees of roughness were obtained by sandblasting PMMA with alumina grains. Hydrophilic and hydrophobic components of the surface free energy (SFE) were calculated according to Good-van Oss's model. Contact angles were determined using a computerized angle meter. The apolar component of the SFE, γsLW, increased with a slight roughness whereas the basic component, γs-, decreased. The acido-basic properties disappeared as roughness increased. Incubation of PMMA in culture medium, performed to test the influence of the biological environment, allowed surface adsorption of medium proteins which annihilated roughness effect and restored hydrophilic properties. An organotypic culture assay was carried out in an attempt to relate the biocompatibility to substratum surface state. Cell migration was calculated from the area of cell layer. Cellular adhesion was determined by measuring the kinetic of release of enzymatically dissociated cells. A slight roughness raised the migration area to an upper extent no matter which cell type. Enhancement of the cell adhesion potential was related to the degree of roughness and the hydrophobicity. © 1997 John Wiley & Sons, Inc. J Biomed Mater Res, 36, 99-108, 1997.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 79
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 36 (1997), S. 550-559 
    ISSN: 0021-9304
    Keywords: polyurethane ; chemical stability ; DSC ; GPC ; FTIR ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: The relative chemical stability of two commercially available polyurethanes - Pellethane, currently used in biomedical devices, and Corethane, considered as a potential biomaterial - was investigated following aging protocols in hydrolytic and oxidative conditions (HOC, water, hydrogen peroxide, and nitric acid) and in physiological media (PHM, phosphate buffer, lipid dispersion, and bile from human donors). The chemical modifications induced on these polymers were characterized using differential scanning calorimetry (DSC), gel permeation chromatography (GPC), and Fourier transform infrared spectroscopy (FTIR). With the exception of nitric acid, all of the aging media promoted a mild hydrolytic reaction leading to a slight molecular weight loss in both polymers. When aged in water and hydrogen peroxide, Pellethane experienced structural modifications through microdomain phase separation along with an increase of the order within the soft-hard segment domains. The incubation of Pellethane in nitric acid also resulted in an important decrease of the melting temperature of its hard segments with chain scission mechanisms. Moreover, incubation in PHM led to an increase of the order within shorter hard-segment domains. FTIR data revealed the presence of aliphatic amide molecules used as additives on the Pellethane's surface. The incubation of Corethane under the same conditions promoted an almost uniform molecular reorganization through a phase separation between the hard and soft segments as well as an increase of the short-range order within the hard-segment domains. Incubation of this polymer in nitric acid also resulted in a chain scission process that was less pronounced than that measured for the Pellethane samples. Finally, lipid adsorption occurred on the Corethane sample incubated in bile for 120 days. Overall data indicate that polycarbonate urethane presents a greater chemical stability than does polyether-urethane. © 1997 John Wiley & Sons, Inc. J Biomed Mater Res, 36, 550-559, 1997.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 80
    ISSN: 0021-9304
    Keywords: cell adhesion ; tissue engineering ; peptide immobilization ; bone cells ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Adhesion, spreading, and focal contact formation of primary bone-derived cells on quartz surfaces grafted with a 15 amino acid peptide that contained a -RGD-(-Arg-Gly-Asp-) sequence unique to bone sialoprotein was investigated. The peptide surfaces were fabricated by using a heterbifunctional crosslinker, sulfosuccinimidyal 4-(N-maleimidomethyl)cyclohexane-1-carboxylate, to link the peptide to amine functionalized quartz surfaces. Contact angle measurements, spectroscopic ellipsometry, and X-ray photoelectron spectroscopy were used to confirm the chemistry and thickness of the overlayers. A radial flow apparatus was used to characterize cell detachment from peptide-grafted surfaces. After 20 min of cell incubation, the strength of cell adhesion was significantly (p 〈 0.05) higher on the -RGD- compared to -RGE- (control) surfaces. Furthermore, the mean area of cells contacting the -RGD- was significantly (p 〈 0.05) higher than -RGE- surfaces. Vinculin staining showed formation of small focal contact patches on the periphery of bone cells incubated for 2 h on the -RGD- surfaces; however, few or no focal contacts were formed by cells seeded on the -RGE- grafted surfaces. The methods of peptide immobilization utilized in this study can be applied to implants, biosensors, and diagnostic devices that require specificity in cell adhesion. © 1997 John Wiley & Sons, Inc. J Biomed Mater Res, 37, 9-19, 1997.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 81
    ISSN: 0021-9304
    Keywords: pathological changes ; cartilage degeneration ; material surface property ; artificial articular cartilage ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: After endoprosthetic replacement of the femoral head, marked pathologic changes of the acetabulum, such as penetration and ulceration, often occur. These changes are caused by the rigid material surface properties of the prosthesis and the lack of damping effects. In this study, we compared the time-dependent changes of tibial articular surfaces with three kinds of femoral implant under loading conditions in dogs. Marked pathologic changes of the menisci and tibial articular cartilage were observed from 8 weeks after implantation with hard material implants, whereas the tibial joint surface against an artificial articular cartilage was still intact 24 weeks postoperatively. These results showed clearly that marked pathologic changes of the articular cartilage against rigid materials occurred and were caused by the surface properties of the counterfaces and high friction coefficients of ceramic and metal materials used. © 1997 John Wiley & Sons, Inc. J Biomed Mater Res, 37, 51-59, 1997.
    Additional Material: 13 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 82
    ISSN: 0021-9304
    Keywords: tissue engineering ; vitronectin ; protein adsorption ; cell adhesion ; surface modification ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: In recent years a central objective of tissue engineering has been understanding the interaction of cells with biomaterial surfaces. In this study we examined the protein adsorption events necessary to control the attachment and the subsequent spatial distribution of bone-derived cells exposed to chemically modified surfaces. Silane chemistry and photolithography techniques were used to create substrates with alternating regions of an aminosilane, N-(2-amino-ethyl)-3-aminopropyl-trimethoxysilane (EDS), alongside an alkylsilane, dimethyldichlorosilane (DMS), on quartz surfaces. Sera depleted of fibronectin (Fn), vitronectin (Vn), or both were used to determine if these proteins were necessary for the initial attachment and spatial distribution of bone-derived cells exposed to modified surfaces in vitro. The kinetics and mechanisms of the spatial distribution of cells were examined using light microscopy and digital image acquisition and subsequently were analyzed. Compared to complete serum, the use of serum depleted of fibronectin with vitronectin included had minimal effect on the cell attachment, spreading, and spatial distribution on the EDS regions of the surface. However, the use of serum depleted of vitronectin with or without fibronectin included resulted in greatly reduced cell attachment and spreading. Thus the presence of vitronectin was required for the attachment, spreading, and spatial distribution of bone-derived cells exposed to EDS/DMS-patterned surfaces. © 1997 John Wiley & Sons, Inc. J Biomed Mater Res, 37, 81-93, 1997.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 83
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 37 (1997), S. 122-129 
    ISSN: 0021-9304
    Keywords: hydroxyapatite ; bone marrow ; osteogenesis ; immunohistochemistry ; in situ hybridization ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: To analyze the bone-bonding property of hydroxyapatite ceramics (HA), composites of rat marrow cells and porous HA were implanted subcutaneously and harvested at 3 to 4 weeks postimplantation. De novo bone formation was observed primarily on the HA surface without fibrous tissue interposition. The HA/tissue interface was analyzed by the observations of thin undecalcified histological sections and fractured surfaces of the implants. The observations were done with a light microscope and a scanning electron microscope (SEM) connected to an energy dispersive spectrometer. The interfacial analyses showed the appearance of osteoblastic cells on the HA surface and that the cells had initiated partially mineralized bone (osteoid) formation directly onto the surface. The osteoid matured into fully mineralized bone, resulting in firm bone bonding to the HA surface. Characterization of osteoblastic cells on the surface was done by determining levels of protein and gene expression of bone Gla protein (BGP, a.k.a. Osteocalcin), i.e., immunohistochemistry and in situ hybridization, respectively. The existence of BGP and mRNA in the cytoplasmic area of the cells confirmed that active osteoblast apposition fabricated primary bone on the HA surface. All of these results indicate the importance of the HA surface in supporting osteoblastic differentiation of marrow stromal stem cells, which leads to firm bone bonding. © 1997 John Wiley & Sons, Inc. J Biomed Mater Res, 37, 122-129, 1997.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 84
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 37 (1997), S. 176-181 
    ISSN: 0021-9304
    Keywords: platelet ; microparticle ; canine ; thrombogenicity ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Assessment of material-induced platelet activation is important given that it is thought to be a major mechanism of biomaterials thrombogenicity. We monitored, by flow cytometry, platelet microparticle (MP) levels in the circulation during the connection of polyvinyl alcohol (PVA) hydrogel and polyethylene (PE) test segments (3.18 mm ID, 20 and 50 cm L) to our chronically shunted beagle dogs. We report that circulating microparticle levels were dependent on test segment material, length, and time. The connection of 50-cm lengths of PVA hydrogel test segments led to MP levels two to three times greater than background at 48 h, while the connection of polyethylene test segments did not lead to elevated microparticle levels. MP levels were near background 24 h after removal of the PVA test segment. To determine platelet life span during the connection of test segments, platelets were labeled in vivo with biotin and their disappearance monitored flow cytometrically. While platelet life span for shunted dogs (no test segment) was 4.7 ± 0.2 days, the connection of PVA hydrogel test segments led to a platelet life span of 〈2 days. © 1997 John Wiley & Sons, Inc. J Biomed Mater Res, 37, 176-181, 1997.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 85
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 37 (1997), S. 207-211 
    ISSN: 0021-9304
    Keywords: radiochemical study ; cholesteryl oleate, dioleoyl phosphatidylcholine ; lysozyme ; uptake by contact lens materials ; artificial tear solutions ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Employing an artificial tear preparation composed of six proteins and six lipids as a deposit model, uptake of the lipids 3H-cholesteryl oleate and 14C-dioleoyl phosphatidylcholine was measured on contact lenses representative of the four FDA hydrogel groups and on select RGP lenses. Cholesteryl oleate uptake after 24 h at 37°C generally was less than 1 μg/lens although occasionally reaching 1-2 μg. DuraSoft 3 lenses (Group IV) accumulated the deposits in greater amounts (p = 0.04) with other lens groups not differing significantly from each other. Ionic DuraSoft 2 and 3 lenses bound more phosphatidylcholine (also 〈1 μg) than other lens groups, possibly reflecting an interaction between the positively charged choline residue and the negative surface of the lens. Lysozyme deposition, measured simultaneously with cholesteryl oleate, bound to a far greater extent to Group IV lenses (e.g., DuraSoft 3, mean surface deposit 279 μg) than to other lens types (p 〈 0.01). Multiple application of the artificial tear solution did not produce a statistically significant increase in cholesteryl oleate accumulation. © 1997 John Wiley & Sons, Inc. J Biomed Mater Res, 37, 207-211, 1997.
    Additional Material: 5 Tab.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 86
    ISSN: 0021-9304
    Keywords: bone ; histometrics ; long-term evaluation ; pure titanium ; amorphous zone ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: We conducted a 2-year histologic and histometric evaluation of the tibial bone-titanium (Ti) implant interface in male rats. Thirty male 6-week-old rats were used in this study. They were divided into two groups: 15 for day 28 and 15 for day 730. Microscopic observation at day 28 revealed that the newly formed bone around the implant almost surrounded the implant, but fibroblastlike cells were interposed in some histologic sections. At day 730, in contrast, such cells were rarely seen, and the bone around the implant presented a lamellar structure. Transmission electron microscopic observation at day 28 disclosed mature or poorly mineralized bone near the implant; however, an electron-dense amorphous zone about 50 nm in thickness was interposed between the bone and Ti. In places slender cells were interposed between the bone and Ti. The amorphous zone was also observed at the cell-Ti interface. At day 730, a poorly mineralized layer remained in some areas between the mature bone and the titanium, and the interposed amorphous zone was still observed. Occasionally, a 200-nm-thick layer, thought to be cell remnant, was seen. As calculated in an image-processing system analysis, the percent bone contact and the thickness and area of the surrounding bone for the Ti implant at day 28 were 43.6%, 30.4 μm, and 0.10 mm2, respectively, and those at day 730 were 89.9%, 53.5 μm, and 0.19 mm2, respectively. In summary, although the passage of time may affect bone maturity, interfacial cells remain at the bone-Ti interface as a uniform layer together with unmineralized bone. © 1997 John Wiley & Sons, Inc. J Biomed Mater Res, 37, 235-242, 1997.
    Additional Material: 16 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 87
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 37 (1997), S. 276-281 
    ISSN: 0021-9304
    Keywords: diffusion interface ; sedimentation ; collagen polymerization ; microgravity ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Collagen solutions (0.25% w/v) were polymerized in microgravity (STS-77, 10 days) along with simultaneous ground controls. Assembly conditions were achieved by the passage of buffer ions across a dialysis membrane into a reaction chamber containing the dissolved collagen. The gels were analyzed macroscopically and microscopically to assess the influence of gravity and the oriented diffusion of buffer ions on the resulting product. Double-blind rankings based on visual observation of the gels established that all of the flight gels (n = 8) were more uniform in appearance than all of the ground gels (n = 6). Photography using side illumination of the gels revealed the more granular appearance of the ground gels relative to the highly uniform appearance of the flight gels. Scanning electron microscopy established this difference at the microscopic level. Proximity to the dialysis interface and the presence or absence of gravity were both found to control the porosity and uniformity of the matrix. © 1997 John Wiley & Sons, Inc. J Biomed Mater Res, 37, 276-281, 1997.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 88
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 37 (1997), S. 314-323 
    ISSN: 0021-9304
    Keywords: fibrinogen adsorption ; high-molecular-weight kininogen ; polyurethanes ; plasma ; blood-material interaction ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: The adsorption of fibrinogen from a single protein solution and from binary mixtures of fibrinogen and high-molecular-weight kininogen (HK) to glass and four sulfonated polyurethane surfaces is reported. The effect of the single-chain (SCHK) and two-chain (TCHK) forms of HK on fibrinogen adsorption was investigated. Using radiolabeling methods, fibrinogen adsorption from a series of mixtures having the same weight ratio of fibrinogen to HK as in plasma (50:1), but varying in total concentration, was measured. Fibrinogen adsorption from the mixtures was reduced on all surfaces compared to the single-protein solution, confirming the highly surface-active nature of this protein. However, except for glass, there was no significant difference between the SCHK and TCHK forms. Polyacrylamide gel electrophoresis and immunoblotting analysis of the proteins eluted from the surfaces after contact with the fibrinogen-SCHK solutions indicated that although intact SCHK was essentially conserved, some transformation of SCHK to TCHK on the surface occurred during the course of the experiment. It is hypothesized that in purified form, in which HK is not complexed to prekallikrein or factor XI, the surface-binding domain is more available than in the complexed forms which are present in plasma. If so, then the removal of bradykinin by kallikrein, as occurs in generating TCHK, may not be required for the expression of surface-binding domain activity. © 1997 John Wiley & Sons, Inc. J Biomed Mater Res, 37, 314-323, 1997
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 89
    ISSN: 0021-9304
    Keywords: bonding-strength ; shear-strength ; simulated body fluid ; push-out measurement ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: This study was undertaken to evaluate the effect of coating characteristics on the mechanical strengths of the plasma-sprayed HA-coated Ti-6Al-4V implant system both in vitro and in vivo. Two types of HA coatings (HACs) with quite different microstructures, concentrations of impurity-phases, and indices-of-crystallinity were used. In vitro testings were done by measuring the bonding-strength at the Ti-6Al-4V-HAC interface, with HACs that had and had not been immersed in a pH-buffered, serum-added simulated body fluid (SBF). The shear-strength at the HAC-bone interface was investigated in a canine transcortical femoral model after 12 and 24 weeks of implantation. The results showed a bonding degradation of approximately 32% or higher of the original strength after 4 weeks of immersion in SBF, and this predominantly depended on the constructed microstructure of the HACs. After the push-out measurements, it was demonstrated that the HACs with higher bonding-strength in vitro would correspondingly result in significantly higher shear-strength at each implant period in vivo. Nevertheless, there were no substantial histological variations between the two types of HACs evaluated. The most important point elucidated in this study was that, among coating characteristics, the microstructure was the key factor in influencing the mechanical stability of the HACs both in vitro and in vivo. As a consequence, a denser HAC was needed to ensure mechanical stability at both interfaces. © 1997 John Wiley & Sons, Inc. J Biomed Mater Res, 37, 335-345, 1997.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 90
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 37 (1997), S. 384-393 
    ISSN: 0021-9304
    Keywords: polymer ; bone bonding ; surface graft polymerization ; deposition of hydroxyapatite ; orthopedics ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: A phosphate-containing polymer was covalently immobilized onto a polyethylene (PE) rod, a poly(ethylene terephthalate) (PET) thread, and a PET film by a surface graft polymerization technique, followed by immersion in calcium phosphate solution to deposit a thin hydroxyapatite (HA) layer on the modified polymer surfaces. The PE rod had a tapered shape, while the PET thread was fixed with clips after implantation, both to minimize the micromovement which may occur in bone. The PE rod was implanted through press-fitting in the femur of rat. Significant enhancement was observed for direct contact of the implant surface with a newly formed bone for both the grafted only and the further HA-deposited PE rods in comparison with the untreated PE at 4, 5, and 6 weeks after implantation. The rats implanted with the modified PET thread in the femur were sacrificed 3 and 6 weeks after implantation. Statistically significant differences were observed for the untreated versus the grafted plus HA-deposited rods at 6 weeks after implantation. To study the resorption of the deposited HA on the methacryloyloxyethylene phosphate-grafted surface, HA-deposited PET films were subcutaneously implanted in the back of rats. The deposited HA was rapidly resorbed within 3 weeks of implantation. These results suggest that the phosphate polymer chains grafted on the PE and PET surfaces effectively induced nucleation and growth of HA crystals. It seems likely that the thin HA layer additionally deposited in vitro onto the grafted PE and PET surfaces was resorbed rapidly and then promoted the growth of HA crystals in vivo. © 1997 John Wiley & Sons, Inc. J Biomed Mater Res, 37, 384-393, 1997.
    Additional Material: 14 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 91
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 37 (1997), S. 413-420 
    ISSN: 0021-9304
    Keywords: tissue engineering ; polylactic acid ; hepatocytes ; transplantation ; portal vein ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Hepatocyte transplantation may provide an alternative to orthotopic liver transplantation to treat liver failure. However, suitable systems to transplant hepatocytes and promote long-term engraftment must be developed. In this study, highly porous, biodegradable sponges were fabricated from poly (L-lactic acid) (PLA), and poly (DL-lactic-co-glycolic acid) (PLGA), and utilized to transplant hepatocytes into the mesentery of three groups of Lewis rats. The portal vein was shunted to the inferior vena cava in one group of rats (PCS). The second group of animals received a PCS and a 70% hepatectomy on the day of sponge-hepatocyte implantation (PCS + HEP), and the control group (CON) received no surgical stimulation. The sponges were vascularized by ingrowth of fibrovascular tissue over the first 7 days in vivo. Approximately 95-99% of the implanted hepatocytes (determined utilizing computer-assisted image analysis) died in all three experimental groups during this time. The number of engrafted hepatocytes in the CON group further decreased over the next 7 days to 1.3 ± 1.1% of the original cell number. However, the number of engrafted hepatocytes in the PCS and PCS + HEP increased over this time to 6 ± 1% and 5 ± 2%, respectively. The number of engrafted hepatocytes in the PCS group continued to increase over the next 2.5 months to a value of 26 ± 12% of the initial cell number, and a large number of engrafted hepatocytes was still present at 6 months. These results indicate that stable new tissues can be engineered by transplanting hepatocytes on biodegradable sponges into heterotopic locations if appropriate stimulation is provided. © 1997 John Wiley & Sons, Inc. J Biomed Mater Res, 37, 413-420, 1997.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 92
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 36 (1997), S. 560-563 
    ISSN: 0021-9304
    Keywords: bone ; implant ; hydroxylapatite ; biocompatibility ; histomorphometric implant saturation ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Bone implant materials are often used to fill in bone gaps that frequently result from orthognathic and craniofacial reconstruction. The substrate hydroxylapatite (HA) is commonly implanted into the bone voids, resulting from these conditions due to its established biocompatibility and osteoconductive properties. The porous structure of HA provides a three-dimensional guideline for fibrovascular ingrowth, facilitating the process that ultimately results in the deposition of new bone. Porous HA (Interpore, 200) implants were implanted in the mandible or maxilla of nine humans and removed after 14-30 months (19.1-month mean). There was no evidence of an inflammatory response. The sample composition and apposition against the implant were determined using point counting and a digitizing tablet and software. Percent ingrowth in available space (%IAS) was defined as %Bone/(%Bone + %Void). A new measure of implant saturation (%IAS - %Apposition of bone) was established to help determine the fundamental manner in which long-term HA implants incorporate bone. In the mean, the samples were composed of 27% bone, 21% void, and 53% implant. The apposition percentages averaged 60% bone, 16% void, and 24% soft tissue. The %IAS averaged 58%, and implant saturation averaged -3%, indicating that a near-balance between the implant and surrounding bone has been established. © 1997 John Wiley & Sons, Inc. J Biomed Mater Res, 36, 560-563, 1997.
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 93
    ISSN: 0021-9304
    Keywords: zinc ; rosin ; resin acids ; cytoprotection ; cytotoxicity ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Combinations of rosin and zinc are used in dentistry as components of periodontal dressings and cements and as root canal sealers. The composition and properties of rosins differ largely depending on source and refinement processes. Rosin (colophony) is composed of approximately 70% resin acids. In order to study the toxic effects of different natural rosins and purified resin acids and the detoxifying effects of zinc, these compounds were analyzed and tested on human polymorphonuclear leukocytes (PMN cells) and human gingival fibroblasts using the radiochromium release method. The rosins and the pure resin acids showed a strong dose-related cytotoxicity, which was inhibited by increased zinc concentrations. The purified resin acids (isopimaric, levopimaric, and neoabietic acid) were more toxic than the natural rosins. The contents of these resin acids might explain the difference in toxicity of the rosins tested. It is concluded that rosin and zinc are not to be considered inert compounds and that the cytoprotective effects of zinc and its role in dentistry products merit further investigations. © 1997 John Wiley & Sons, Inc. J Biomed Mater Res, 37, 20-28, 1997.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 94
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 37 (1997), S. 94-99 
    ISSN: 0021-9304
    Keywords: fatigue crack growth ; finger joint spacers ; prosthesis ; polymers ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Silastic small joint spacers for the metacarpo-phalangeal joint fail catastrophically at a reported rate ranging from 2 to 26%. Although the exact cause of this problem is not known, it is speculated that failure is due to the propagation of flaws generated in the material surface. In addition to wear secondary to bony impingement, these flaws can be introduced through manufacturing, surgical handling, and in vivo frictional wear. In an effort to identify an elastomeric material that will function similarly to Silastic as a self-hinging joint spacer but provide an increased functional ife, we have investigated and compared the crack-growth properties of two polyurethanes, ChronoFlex and Medica-flex, and a thermoplastic elastomer, Santoprene, with those of Silastic. The materials were evaluated after sterilization by either ethylene oxide or gamma irradiation in an ASTM standard flexing machine under conditions of high humidity and body temperature both before and after artificially aging. In each case, the materials investigated presented significantly lower crack-growth rates than Silastic (p 〈 0.001). © 1997 John Wiley & Sons, Inc. J Biomed Mater Res, 37, 94-99, 1997.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 95
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 37 (1997), S. 539-547 
    ISSN: 0021-9304
    Keywords: in vivo ; soft-tissue reaction ; scanning electron microscopy ; confocal laser scanning microscopy ; three-dimensional reconstruction ; implant interface ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: It has been suggested that during wound healing microtextured surfaces can alter events at the interface between implant surface surface and surrounding tissues. To investigate this phenomenon, smooth and microtextured silicone rubber implants were implanted subcutaneously in rabbits for 3, 7, 42, and 84 days. The textured implants possessed parallel surface microgrooves and ridges with a width of 2.0, 5.0, and 10.0 μm. All grooves had a depth of approximately 0.5 μm. SEM observation showed fibroblasts, erythrocytes, lymphocytes, macrophages, fibrin, and collagen on all implant surfaces after 3 and 7 days. After 42 and 84 days only little collagen, a small number of fibroblasts, but no inflammatory cells were seen on the implant surfaces. The fibroblasts were not oriented along the surface grooves on all textured surfaces. Three-dimensional reconstruction of CLSM images and LM images showed no significant differences between the thickness of the capsules surrounding the smooth and those surrounding the microgrooved implants. In contrast, LM did show a significantly lower number of inflammatory cells and a significantly higher number of blood vessels in the capsules surrounding the microgrooved implants. Differences between the 2.0, 5.0, and 10.0 μm grooved implants were not detected. Our results concerning the capsule thickness suggest that the depth of our grooves was not sufficient to facilitate mechanical interlocking, but the cause for the observed differences in inflammatory response and number of blood vessels remains unclear. © 1997 John Wiley & Sons, Inc. J Biomed Mater Res, 37, 539-547, 1997.
    Additional Material: 12 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 96
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 37 (1997), S. 573-584 
    ISSN: 0021-9304
    Keywords: excimer laser ; polyurethane ; vascular graft ; compliance ; porosity ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: The microporous structure of artificial vascular grafts, which increases compliance and porosity simultaneously, may enhance neoarterial regeneration. In order to differentiate these effects, three models of segmented polyurethane grafts (inner diameter, 1.5 mm; wall thickness, 100 μm) with or without micropores fabricated using an excimer laser ablation technique, were prepared, and their neoarterial regenerative potentials were studied upon implantation: Model I (microporous, permeable, compliant); Model II (smooth-surfaced, impermeable, compliant); and Model III (smooth-surfaced, impermeable, noncompliant). In Models I and II, the pore or groove size (diameter, 100 μm) and pore or groove arrangement were fixed, and consequently their compliances were almost identical. Irrespective of model, the luminal surfaces were coated with benzophenone-derivatized gelatin and subsequently photocured. Twenty grafts (length, 20 mm) of each model were implanted in the aortas of rats. Predetermined implantation periods were 4, 12, and 24 weeks. Total patency rate decreased in the order Model I (100%), II (87%), and III (59%) grafts. All patent grafts were completely endothelialized after 12 weeks of implantation, irrespective of model. After 12- and 24-week implantations, in Model I grafts, the neoarterial wall was thin, and smooth muscle cells (SMCs) were of the contractile phenotype. In Model II grafts, the neoarterial wall exhibited considerable thickening. In Model III grafts, the neoarterial wall exhibited marked thickening, and SMCs were of the synthetic phenotype. The neoarterial wall thickness at the midportion of the grafts after 24 weeks of implantation increased in the order Model I (48 ± 8 μm), II (146 ± 87 μm), and III (385 ± 21 μm) grafts. These results strongly suggest that compliance matching and porosity synergistically resulted in neoarterial wall restoration without appreciable thickening. © 1997 John Wiley & Sons, Inc. J Biomed Mater Res, 37, 573-584, 1997.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 97
    ISSN: 0021-9304
    Keywords: hyaluronic acid ; tendon ; adhesion ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Tendon adhesion is acknowledged to be a function of both an overwhelming inflammatory response at the surgical site and the loss of physical separation that is normally present between the tendons and the synovial sheath. Adhesions bind the flexor tendons to each other and to surrounding structures, interfering with their normal gliding function. The clinical result of adhesion formation following flexor tendon surgery is poor digital function. This study investigated the effect of intraoperative treatments of high viscosity absorbable gels made of various combinations of hyaluronic acid and nonsteroidal anti-inflammatory drugs, on adhesion formation in a leghorn chicken flexor tendon model. Forty-eight mature, white leghorn chickens were used to verify the surgical model and to test five different gel treatments. The gels were formed from: 2% sodium hyaluronate in phosphate buffered saline alone or combined with 1 mg/mL tolmetin sodium; 1 mg/mL naproxen sodium; 0.216 g/mL calcium acetate; or 0.216 g/mL calcium acetate plus 1 mg/mL naproxen sodium. The gels were applied by injecting 0.2 mL of the specified composition into the intrasheath space near the conclusion of the surgical procedure. Gross and histological evaluations were conducted to analyze the efficacy. All of the treatments significant reduced the extent and severity of postsurgical tendon adhesion in this animal model as compared with the control (no gel treatment) (p 〈 0.05). The combination of naproxen sodium and calcium acetate in a high viscosity sodium hyaluronate carrier was the most effective composition. The combination of a high viscosity gel and nonsteroidal anti-inflammatory drugs appears to maintain the natural separation between the tendons and their sheaths and decrease the tissue inflammatory response through mediating two of the major stimuli in adhesion formation. © 1997 John Wiley & Sons, Inc. J Biomed Mater Res (Appl Biomater) 38: 25-33, 1997
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 98
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 34 (1997), S. 317-326 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: To develop rapidly biodegradable “stealth” nanoparticles, a physicochemical investigation was done on the formation of PEG-coated poly(isobutyl 2-cyanoacrylate) (PIBCA) nano-particles. In particular, this study focused on the effect of polymerization conditions on particle size and surface properties, such as charge and hydrophilicity. Among the parameters involved, the pH of the polymerization medium was found to be a key to control the preparation of PEG-coated nanoparticles. Currently, poly(alkylcyanoacrylate) (PACA) nanoparticles are prepared in H2O at pH 2.5, the most appropriate for producing nanoparticles with a mean diameter of 200 nm and an unimodal size distribution. The presence of PEG in the polymerization medium was shown to affect particles formation: only a pH value 〈 1.5 led to the formation of colloidal nanoparticles, and slight pH variations dramatically affected particle size and PEG association. Polymer chemistry investigations and chemical determination of PEG strongly suggest that PEG associated with nanoparticles was well copolymerized with PIBCA. © 1997 John Wiley & Sons, Inc.
    Additional Material: 10 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 99
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 34 (1997), S. 341-349 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: The mechanical properties and structure of a human common carotid artery were studied in order to develop criteria for designing and manufacturing compliant textile vascular grafts. The arterial wall comprised a composite of elastin and collagen fibers with the collagen fibers crimped. This structure led to a unique pressure-circumferential stretch ratio curve, the slope of which increased with an increase in strain. The increase in slope was particularly rapid at a stretch ratio above 1.4 or pressure above 120 mmHg. Based on the knowledge gained, a criteria for the design of biomechanically compliant arterial grafts was developed. An elastomeric prestretched polyurethane monofilament yarn with a low modulus of elasticity and a bulked polyester multifilament yarn with a high modulus of elasticity were combined and used as threads in the manufacture of grafts. Tubular structures of diameters in the range 4-6 mm were made by weaving. Transverse compliance and morphological and permeability properties of these grafts were determined and compared with those of a currently available woven commercial grafts and human carotid arteries. Results indicated that the compliance values of the hybrid grafts were comparable with those of the human carotid artery. Preliminary in vivo studies in dogs showed promising results: a thin, stable neointima developed within 6 months of implantation on the flow surface. © 1997 John Wiley & Sons, Inc.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 100
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 34 (1997), S. 393-400 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Following the signal observation that contact with positively charged dextran resin (PCDR) inhibited the growth of cultured mammary (Hs578T and MDA-MB-231), pancreatic (H2T), and myeloma (RR-658) tumor cell lines, studies were developed in the hamster cheek pouch model using hamster H2T pancreatic tumor cells to determine if the antiproliferative effect of PCDR could inhibit tumorigenesis. In these studies, the control population represented groups injected with H2T cells alone or in combination with either neutral or negatively charged resin. When cells (5 × 102 to 1 × 105) and PCDR were administered simultaneously, the tumor incidence (percent engraftment) and growth of tumors that already had been established were significantly reduced. When PCDR was injected into already established 1-35-mm2 H2T tumors (engraftment for 21 days = 96%), the resin suppressed the growth of the smallest tumors (〈 10 mm2). In none of these trials was the somatic growth of the host hamsters affected. PCDR contact with H2T cells in vitro for 4 days or used to treat growing solid tumors for 72 days significantly reduced cellular ornithine decarboxylase activity. While the mechanism of PCDR action has not been established, the observations have implications for in vivo tumor therapeutic models. © 1997 John Wiley & Sons, Inc.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...