ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Column liquid chromatography  (95)
  • Springer  (95)
  • Cambridge University Press
  • Ottawa
  • Ottawa : Geological Survey of Canada
  • 1990-1994  (95)
  • 1945-1949
  • 1994  (95)
Collection
Publisher
  • Springer  (95)
  • Cambridge University Press
  • Ottawa
  • Ottawa : Geological Survey of Canada
Years
  • 1990-1994  (95)
  • 1945-1949
Year
  • 1
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Column-switching ; Determination of triamterene ; Fluorescence detection
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A liquid chromatographic method incorporating column-switching and fluorimetric detection for the determination of triamterene in untreated urine, is described. The urine samples (5 μL) were directly introduced onto an Hypersil ODS-C18, 30 μm (20 mm×2.1 mm I.D.) pre-column. Polar urinary compounds were removed by flushing the pre-column with water for 1 min, and the analyte was then switched onto an HP-LiChrospher RP C18,5 μm (125 mm×4mm ID) analytical column using an acetonitrile/phosphate buffer gradient elution. Fluorescence detection was performed at 230 nm excitation and 430 nm emission wavelengths. The recovery of drug was 102±2% in the 0.10–20.0 μg/mL concentration range, the limit of detection being 5 ng/mL. A validation of the usefulness of this procedure was accomplished by analysing urine extracts obtained from real samples.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Characterization of reversed phases ; Column hydrophobicity ; Column hydrophylicity
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The validity of a method for characterizing stationary phases for reversed-phase, liquid chromatography, based on the use of homologous series, has been evaluated. The method is based on a retention model which describes the dependence of the logarithm of the capacity factor on mobile phase composition and the carbon number of specific homologous series. A first-order as well as a second-order version of this model was investigated. The second-order model proved to be a significant improvement on the first-order model, even for smaller mobile-phase ranges. Nevertheless both models showed a significant lack of fit, reflecting the incompleteness of these models. Therefore, it is very questionable whether this method is suitable to describe HPLC-column characteristics like hydrophobicity and hydrophylicity.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Copoly(styrene/acrylonitrile) ; Gradient elution ; Precipitation chromatography of polymers ; Solubility of polymers
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Copolymers from styrene and acrylonitrile could be separated according to composition by gradient elution through methanol after injection inton-heptane and sudden addition of 50, 60, or 70 vol% tetrahydrofuran. The peak sequence was the same as with a common binary gradientn-heptane/tetrahydrofuran, i.e., retention increased with acrylonitrile content of the samples. With copolymers containing 37, 31, or 26% acrylonitrile, the elution characteristics in the ternary systems could be logically extrapolated towards the points measured in the corresponding binary gradient system.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Chiral recognition ; Aminoalkylphosphonic acid derivatives ; β-cyclodextrin bonded phases
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary An acetylated β-cyclodextrin column was used to analyse the enantiomeric resolution of a number of aminophosphonic acids. Effects of the structure of these compounds on the extent of separation was examined. Molecular modelling studies were also carried out in an attempt to relate any interaction between the amino and phosphonic acid groups to chiral recognition by the stationary phase.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Chiral separation ; Association constants ; Frontal analysis ; Cyclodextrin bonded-phases
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The interaction between cyclodextrin and the drug (1R,2S,3S,4S)-(5Z)-7-(3-((phenylsulfonyl)amino)bicyclo[2.2.1]hept-2-yl)hept-5-enoic acid ((+)-S-145), was studied using α-, β-, and γ-cyclodextrin bonded-phase columns. Retention behavior of (+)-S-145 on these columns revealed that the strength of inclusion was β→γ→α-cyclodextrin. Interaction between β-cyclodextrin and (+)-S-145 was found to increase as the proportion of carboxylic ion in the (+)-S-145 molecule increased. Comparison of binding capacities of these bondedsilica gels obtained by frontal analysis and surface coverage indicated that availability of the immobilized β- and γ-cyclodextrin was 20–25%. The synthesized β-cyclodextrin bonded-phase column was superior to that of commercial columns in terms of chiral separation of (±)-S-145. A typical usage of the β-cyclodextrin column is discussed for separation of (±)-S-145 in plasma samples.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Primary and secondary aliphatic alcohols ; Aqueous derivatization ; Phthalic acid monoesters
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Determination of primary and secondary aliphatic alcohols in aqueous and nonaqueous solutions by high-performance liquid chromatography (HPLC) is described. The alcohol is derivatized with phthalic anhydride to yield the corresponding monophthalate. Separation of the derivative is achieved on an ODS-10 reverse phase (RP) column by elution with an appropriate isocratic mobile phase of acetonitrile and aqueous phosphoric acid (0.1%). Detection is accomplished by UV absorption at 230 nm or 280 nm giving linear calibration plots, for alcohols in aqueous solution from 0.05% to 0.50% (w/v) and in pyridine solution from 0.0025% to 0.0250% (w/v).
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Hybrid mobile phases containing alcohols ; Solute-micelle association constants ; Polynuclear aromatic hydrocarbons
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The interaction between some polynuclear aromatic hydrocarbons of environmental concern, and sodium dodecylsulphate and hexadecyltrimethylammonium bromide in the presence of methanol, 2-propanol and n-butanol has been evaluated by high-performance liquid chromatography using micellar mobile phases. Solute-micelle association constants have been determined for the compounds investigated. The results show that the addition of the alcohol to the mobile phase decreases the association constant values, methanol 〈2-propanol 〈n-butanol, relative to those in the absence of any additive.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 38 (1994), S. 571-578 
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Wine ; Biogenic amines ; Solid-phase extraction ; Derivatization
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A method suitable for the determination of 19 biogenic amines in wine has been developed. The method involves derivatization of amines by treatment with dansyl chloride and solid-phase extraction of the derivatives. Prior to the derivatization procedure, clean-up of the wine sample with polyvinylpyrrolidone is carried out. Reversed-phase gradient elution HPLC with UV detection at 250 nm was used to determine these compounds. Some consideration was given to the effect of temperature on the separation process. Linearity of derivatization was obtained for amounts of all the biogenic amines ranging from 500 μg·L−1 to 20 mg·L−1. Limits of detection (signal-to-noise ratio=3) of the amines were similar for all the dansylderivatives (between 50 and 150 μg·L−1). Addition of standard amines was used for the determination of amine recoveries. These were better than 85% for ethanolamine, tryptamine, phenetylamine, putrescine, cadaverine and histamine. The overall process was succesfully applied to identify and quantify biogenic amines in white and red wines.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Chiral/enantiomeric iseparation ; Cellulose-based chiral phases ; Tifluadom analogues ; 2-acylaminomethyl-1,4-benzodiazepines
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The resolution of nine recamic mixtures of tifluadom analogues has been evaluated using the chiral stationary phases Chiralcel OD and Chiralcel OJ. The separation was performed on an analytical scale to optimize the conditions for chiral resolution, approaching baseline separation, of the two enantiomers. Eight racemates were baseline separated on Chiralcel OJ using a mobile phase of hexane/2-propanol.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Phenolic compounds ; Ion-pair solid-phase extraction ; Comparison of sorbents
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A comparative study of the solid phase extraction of phenolic compounds in water was carried out. Three different sorbents, C18, CH and PLRP-S, were tested for the preconcentration process in order to determine phenolic compounds in water at μg l−1 levels by reversed-phase LC separation and diode-array detection. The addition of an ion-pair reagent in the extraction process was also studied in order to increase the breakthrough volume of some compounds. Using the optimized conditions the limit of detection was less than 0.5 μg l−1, the maximum admissible concentration (MAC) in drinking water. The method was applied to determine phenolic compounds in Ebro river water however no phenols were found within the detection limits of the method.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...