ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Articles  (2)
  • Arteries  (2)
  • 2010-2014
  • 1990-1994  (2)
  • 1985-1989
  • 1950-1954
  • 1990  (2)
  • Technology  (2)
  • History
Collection
  • Articles  (2)
Publisher
Years
  • 2010-2014
  • 1990-1994  (2)
  • 1985-1989
  • 1950-1954
Year
Topic
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Annals of biomedical engineering 18 (1990), S. 89-101 
    ISSN: 1573-9686
    Keywords: Cardiovascular ; Arteries ; Veins ; Pressure-flow relationships ; Waterfall
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine , Technology
    Notes: Abstract We developed and tested a new two-compartment serial model of the arterial vasculature which unifies the capacitance (downstream arterial compliance) and waterfall (constant downstream pressure load) theories of blood flow through the arteries. In this model, blood drains from an upstream compliance through a resistance into a downstream compliance which empties into the veins through a downstream resistance which terminates in a constant pressure load. Using transient arterial pressure data obtained from an isolated canine hindlimb preparation, we tested this model, using a stop-flow technique. Numerical parameter estimation techniques were used to estimate the physiologic parameters of the model. The downstream compliance was found to be more than ten times larger than the upstream compliance and the constant pressure load was significantly above venous pressures but decreased in response to vasodilation. Our results support the applicability of both the capacitance and waterfall theories.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1435-604X
    Keywords: Arteries ; Laser angioplasty ; Transluminal angioplasty ; Heart ; Coronary artery disease ; Lasers
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine , Physics , Technology
    Notes: Abstract We report our experience in 60 patients using a recently designed 4 French ring catheter system for coronary and a 7 French ring catheter for peripheral percutaneous excimer laser angioplasty. The advantages in comparison to bare fibres comprise an improved flexibility and a central channel for insertion of guide wires to minimize the risk of mechanical vessel wall perforation. The peripheral laser catheter initially transmitted overall energies of 20 mJ pulse−1 (51 mJ pulse−1 mm−2), the coronary device 4.5–5 mJ pulse−1 (32 mJ pulse−1 mm−2). A 50% or more decrease of energy transmission was found in 43% of coronary catheters due to a number of blinded fibres with other fibres remaining intact. This was either due to a retrograde expansion of shock waves generated by the excimer pulse at a calcified lesion, or the result of a deleterious back-reflection of the laser light by contrast media. However, using both laser catheters ablation of plaque in vivo proved to be possible. Small mechanical defects of the catheter tips in 27% did not result in patient related complications. Our initial experience favours further improvement of ring catheters for percutaneous excimer laser angioplasty.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...