ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Life and Medical Sciences  (697)
  • Physics  (538)
  • INSTRUMENTATION AND PHOTOGRAPHY
  • 1980-1984  (1,493)
  • 1965-1969
  • 1983  (1,493)
Collection
Publisher
Years
  • 1980-1984  (1,493)
  • 1965-1969
Year
  • 1
    Publication Date: 2004-12-04
    Description: An improved 4 to 18 micron array camera system was developed at NASA Goddard SFC for astronomical photometry, using an Aerojet Electro Systems Corp. 16 x 16 Si:Bi accumulation mode charge injection device (AMCID) which could be suitable for eventual low-background spaceflight applications. An astronomical observing program using this device was carried out as a collaboration between NASA Goddard (Infrared and Radio Astronomy Branch and Micro Electronics Branch), the Harvard/Smithsonian Center for Astrophysics, and Steward Observatory of the University of Arizona. In 1983 the camera system was revised, and a new Aeroject Si:Bi array with 16 x 16 active pixels was obtained from NASA/Ames Research Center as part of a new scientific collaboration between the Ames and Goddard infrared array research groups. The 16 x 16 device had sufficiently good sensitivity, uniformity and noise characteristics to be used for successful observations at the Mt. Lemmon 60 and 61 inch telescopes in May 1983. Complete laboratory characterization of the 16 x 16 array was carried out in summer of 1983. Initial results indicate that this detector has sensitivity and noise characteristics comparable to other devices from the same generation of Aerojet arrays.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA. Ames Research Center, Infrared Detector Technology Workshop; 12 p
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Publication Date: 2011-08-18
    Description: New frequency calibration tables are required to keep abreast of the resolution attainable by currently available tunable lasers. One key to the generation of tables with requisite accuracy involves accurate heterodyne frequency measurements; another key consists of reliable fitting and analysis. Coordinated activity in NBS involves selection of suitable molecular calibration candidates, their frequency measurement and analysis, and dissemination of the results in the form of frequency calibration tables. Current status of these efforts is described.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    facet.materialart.
    Unknown
    In:  Other Sources
    Publication Date: 2011-08-18
    Description: A new extension to optogalvanic spectroscopy, in which electrons detached from negative ions formed in the discharge are observed as a function of incident laser wavelength, has been developed. The determination of the electron affinities of I(-) and Cl(-) atomic ions is described. The potential of the technique for studying the spectroscopy of molecular negative ions is also discussed.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Journal de Physique (ISSN 0449-1947); 44; C7-461 t
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Publication Date: 2011-08-18
    Description: A holographic interferometer system has been installed in the NASA Ames 2- by 2-Foot Transonic Wind Tunnel. The system incorporates a modern 10 pps, Nd:YAG pulsed laser which provides reliable operation and is easy to align. The spatial filtering requirements of the unstable resonator beam are described, as well as the integration of the system into the existing schlieren system. A two-plate holographic interferometer is used to reconstruct flow field data. For static wind tunnel models, the single exposure holograms are recorded in the usual manner; however, for dynamic models such as oscillating airfoils, synchronous laser hologram recording is used.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Publication Date: 2011-08-18
    Description: A new two-wavelength lidar technique for remotely measuring the pressure profile using the trough absorption region between two strong lines in the oxygen A band is described. The theory of integrated vertical path, differential ranging, and horizontal-path pressure measurements is given, with methods to desensitize and correct for temperature effects. The properties of absorption troughs are described and shown to reduce errors due to laser frequency jitter by up to two orders of magnitude. A general analysis, including laser bandwidth effects, demonstrates that pressure measurements with an integrated-vertical-path technique are typically fifty times more accurate than with a differential ranging technique. Simulations show 0.1-0.3 percent accuracy for ground and Shuttle-based pressure-profile and surface-pressure experiments.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Applied Optics (ISSN 0003-6935); 22; 3759-377
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Publication Date: 2011-08-18
    Description: Airborne laser-induced, depth-resolved water Raman backscatter is useful in the detection and mapping of water optical transmission variations. This test, together with other field experiments, has identified the need for additional field experiments to resolve the degree of the contribution to the depth-resolved, Raman-backscattered signal waveform that is due to (1) sea surface height or elevation probability density; (2) off-nadir laser beam angle relative to the mean sea surface; and (3) the Gelbstoff fluorescence background, and the analytical techniques required to remove it. When converted to along-track profiles, the waveforms obtained reveal cells of a decreased Raman backscatter superimposed on an overall trend of monotonically decreasing water column optical transmission.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Applied Optics (ISSN 0003-6935); 22; 3778-378
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Publication Date: 2011-08-18
    Description: Eight dual channel microwave radiometers were constructed as a research and development effort for the Crustal Dynamics Project and the Deep Space Network. These instruments, known as water vapor radiometers, are primarily intended to demonstrate that the variable path delay imposed by atmospheric water vapor can be calibrated in microwave tracking and distance measuring systems but could also be used in other applications involving moist air meteorology and propagation studies. They are being deployed to various stations and observatories that participate in Very Long Baseline Interferometry experiments. The development history of these instruments are reviewed, the theory of operation and overall design considerations are outlined, and the instrumental parameters and performance characteristics are described.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: The Telecommun. and Data Acquisition Rept.; p 1-19
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    facet.materialart.
    Unknown
    In:  Other Sources
    Publication Date: 2011-08-18
    Description: The design and performance of the high-density digital recorder (HDDR) developed for use at the NASA centers (KSC, JSC, and GSFC) and at the JPL to store and retrieve 50-Mb/s PCM data streams from the Spacelab experiments are reported. The recording reproduction, and transport requirements are reviewed; and the design solutions adopted in the final version of the HDDR are described, incuding three-position-modulation and Y-phase encoding, microprocessor-controlled automatic bit synchronization and equalization, cyclic-redundancy-check error detection and correction, clock regeneration, data and clock variations, tape-speed control, and EEE-488 remote control. Reliable performance, with bit error rates 1 in 10 to the 10th forward and 1 in 10 to the 9th reverse or better and packing density up to 50 percent greater than that obtainable using conventional codes, is reported after 1.5 years of service.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Publication Date: 2011-08-18
    Description: To support the development of advanced infrared remote sensing instrumentation using line and area arrays, a test facility has been developed to characterize the detectors. The necessary performance characteristics of the facility were defined by considering current and projected requirements for detector testing. The completed facility provides the desired level of detector testing capability as well as providing ease of human interaction.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Publication Date: 2011-08-18
    Description: Two comparisons of available specular infrared measurements using identical or very similar coatings reveal that specular BRDF (bidirectional reflectance distribution function) measurements of rough coatings are comparable but that simple measured reflectances are not. This is seen as indicating that the diffuse component of the measured specular reflectance is significantly larger than that of the specular component. It is noted that the diffuse component of the measurement is a convolution of the intrinsic directional reflectivity of the surface with the instrument function and that because the value of that function increases at the wavelengths under consideration, the diffuse component is larger than would otherwise be expected. The BRDF normalization is found to cause a primitive deconvolution of the instrument function and to produce a quantity that is approximately equal to the mean intrinsic directional reflectivity very near the specular direction. The analysis and comparison of data reveal that nonspecular BRDF measurements at angles well outside the instrument function can be calibrated as well by an image of the source upon the detector as by reference to a known surface.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...