ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Articles  (2)
  • immunology  (2)
  • Wiley-Blackwell  (2)
  • Copernicus
  • National Academy of Sciences
  • 2010-2014
  • 1980-1984  (2)
  • 1945-1949
  • 1925-1929
  • 1983  (2)
  • Physics  (2)
Collection
  • Articles  (2)
Publisher
  • Wiley-Blackwell  (2)
  • Copernicus
  • National Academy of Sciences
Years
  • 2010-2014
  • 1980-1984  (2)
  • 1945-1949
  • 1925-1929
Year
Topic
  • 1
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 4 (1983), S. 141-155 
    ISSN: 0197-8462
    Keywords: microwave bioeffects ; hamster macrophages ; immunology ; viricidal macrophages ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: Acute exposure of hamsters to microwave energy (2.45 GHz; 25 mW/cm2 for 60 min) resulted in activation of peritoneal macrophages that were significantly more viricidal to vaccinia virus as compared to sham-exposed or normal (minimum-handling) controls. Macrophages from microwave-exposed hamsters became activated as early as 6 h after exposure and remained activated for up to 12 days. The activation of macrophages by microwave exposure paralleled the macrophage activation after vaccinia virus immunization. Activated macrophages from vacciniaimmunized hamsters did not differ in their viricidal activity when the hamsters were microwave or sham-exposed. Exposure for 60 min at 15 mW/cm2 did not activate the macrophages while 40 mW/cm2 exposure was harmful to some hamsters. Average maximum core temperatures in the exposed (25 mW/cm2) and sham groups were 40.5 °C (±0.35 SD) and 38.4 °C (±0.5 SD), respectively. In vitro heating of macrophages to 40.5 °C was not as effective as in vivo microwave exposure in activating macrophages to the viricidal state. Macrophages from normal, shamexposed, and microwave-exposed hamsters were not morphologically different, and they all phagocytosed India ink particles. Moreover, immune macrophage cytotoxicity for virus-infected or noninfected target cells was not suppressed in the microwave-irradiated group (25 mW/cm2, 1 h) as compared to sham-exposed controls, indicating that peritoneal macrophages were not functionally suppressed or injured by microwave hyperthermia.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 4 (1983), S. 383-396 
    ISSN: 0197-8462
    Keywords: hematology ; immunology ; mice ; pulsed microwaves ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: Mice were exposed in the far field in an anechoic chamber to 2,880-MHz pulsed microwaves 3 to 7.5 h daily, 5 days/week for 60 to 360 h. Three experiments were performed at average power densities of 5 mW/cm2 and six at 10 mW/cm2, corresponding to averaged specific absorption rates (SARs) of 2.25 and 4.50 mW/g, respectively. Each experiment consisted of eight mice, with a concurrently sham-exposed group of eight. In two of three studies at 5 mW/cm2, there was a significant increase in bone marrow cellularity in the microwave-exposed groups compared to the sham-exposed groups. Significant differences were occasionally seen in erythrocyte, leukocyte, and platelet values from microwaveexposed groups, but were not consistently observed. In one of six groups exposed at 10 mW/cm2, mean bone marrow cellularity was reduced significantly in the microwaveexposed mice; in another group, the lymphocyte count was increased. In only one exposure (10 mW/cm2 for 360 h) was any significant effect noted on serum proteins: a reduction to 5.1 ± 0.3 g/dl in the exposed versus 5.6 ± 0.4 g/dl in the sham-exposed mice. This was due to a decrease in alpha and beta globulins, with no effect on albumin or gamma globulin concentrations. No effect on bone marrow granulocyte/macrophage colony-forming units (CFU) was revealed following exposure of mice to pulsed microwaves at 5 mW/cm2. In one of four exposures at 10 mW/cm2, there was a significant increase in CFU-agar colonies. No significant effects of exposures at 10 mW/cm2 were observed on in vivo and in vitro assays of cell-mediated immune functions. No exposure-related histopathologic lesions were found from examination of several tissues and organs. Results of these series of exposures of mice at SARs of 2.25 and 4.50 mW/g indicated no consistent effects on the hematologic, immunologic, or histopathologic variables examined.
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...