ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Capillary, glass  (45)
  • Wiley-Blackwell  (45)
  • Annual Reviews
  • Periodicals Archive Online (PAO)
  • 1975-1979  (45)
  • 1970-1974
  • 1979  (45)
Collection
Publisher
  • Wiley-Blackwell  (45)
  • Annual Reviews
  • Periodicals Archive Online (PAO)
Years
  • 1975-1979  (45)
  • 1970-1974
Year
  • 1
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 2 (1979), S. 288-292 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; Stationary phases, polar, gum type ; For temperatures up to 300°C ; For most of the common classes of organic compounds ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Most of the common classes of organic compounds chromatograph normally on Superoxes. There is no tailing or adverse effect from excessively different activity different activity coefficients. Superoxes are therefore universal phases for gas chromatography. This is also expressed by a wide useful temperature range from ∼50° to ∼300°. High MW Superox-4 has a MAOT about 20° higher than the lower MW Superox-0.1. Several applications illustrating the versatility of Superox phases in (GC)2 are presented.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 2 (1979), S. 429-435 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; Surface roughening by diatomaceous support (5 micron particles deposition) ; Organic glue (polar polymethacrylate acetate) used as intermediate material ; Reproducibility and durability of capillaries discussed ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A technique for adhesion of fine particles (ca. 5 μ) of the 405 white diatomaceous support on the inner wall of glass tube with organic glue [poly (diethylaminoethyl methacrylate) acetate] is described. The coated tube was drawn to capillary column by using a machine designed according to Desty's. The capillary column was then coated with stationary phase (such as squaiane, QF-1, Dexsil 300, PEG 20 M, OV-1, SE 30 and etc.) by the conventional dynamic or static method. This preparation method has proved easy to duplicate and is simple. The coating efficiency (UTE %) is within 60-90. The theoretical plate number per meter of an SE 30 column is about 4000, and per meter of a PEG 20 M column is about 2500. The columns thus prepared have been successfully used to analyze petroleum hydrocarbons, essential oils, petrochemicals, pheromone, steroid metabolites and others.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 2 (1979), S. 283-287 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; Sampling technique ; Semi-automation of head space sampling ; Application to water pollution, coffee aroma, light hydrocarbons in crude oil ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Head space GC using a special electropneumatic sampling system works well in combination with glass capillaries. Because a homogenous gas mixture is already present most problems inherent with inlet splitters are thus avoided. In cases where the high vapor pressure of the sample can cause problems with the pressure controlled sampling system, the use of narrow bore glass capillaries provides the necessary inlet pressure. The use of this powerful and convenient analytical tool for water pollution analysis, flavour analysis and the analysis of volatiles in crude oil samples is shown by examples.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 2 (1979), S. 319-323 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; Mobile phase flow programming ; Comparison with temperature programming ; Short capillaries offer considerable shorter analysis time when flow programmed ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The technique of programming the carrier gas flow rate in gas chromatography, especially in connection with the use of capillary columns shorter than 10 m can significantly accelerate GC analyses. Equations for calculation of the parameters of the exponential flow function and retention data are described. The effects of flow programming in a short capillary column are shown in a few chromatograms. Different programming rates are tested and compared with temperature programming.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 2 (1979), S. 297-302 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; Surface roughening ; Amorphous silica ; Deactivation ; Column performance ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A new method for the preparation of wall-coated glass capillary columns after surface roughening by means of amorphous silica is described. After the glass capillary has been leached, a small quantity of amorphous silica is deposited evenly on the inner surface. This is done by passing a plug of dilute water glass through the capillary, followed by a flow of gaseous hydrochloric acid. The roughened surface is stabilized, deactivated and finally coated.This paper furnishes details of the technique and information about the performance of a number of columns prepared by the method.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 2 (1979), S. 324-328 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; Theory in contrast to traditional approaches ; Very practical formulas for peak width, maximum load, concentration in mobile phase ; Optimizing procedure for trace analysis ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: In contrast to traditional theoretical approaches by calculation of (nonexistent) theoretical plates, a unified theory of gas chromatography as given by a definition of the resolution analogue to methods in signal processing or spectroscopy using the well-known Kovacz indices as fundamental scale. A derivation of the thusly defined resolution from basic physical principles yields very practical formulae for peak width, maximum load, substance flow in peak maximum, concentration of substance in the carrier gas and other interesting parameters in dependence of capillary diameter, capillary length, film thickness, carrier gas speed, viscosities etc. Diagrams show favourite conditions for detectors responding on absolute substance flow (e.g. FID) or on concentrations.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 2 (1979), S. 400-404 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; Low temperature plasma etching ; Polymer film on the inner surface from organosilicone monomer ; Flexibility of this new method discussed ; Discharge chamber described ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A novel method is described for the preparation of stable glass capillary columns (glass open tubular columns), including the etching and formation of a polymer film on the inner glass capillary surfaces. The approach used here is based on low-temperature plasma etching and polymerization. Under the influence of a field of radio frequency discharge, low pressure gases of fluoric compounds, introduced into the glass capillary tube, generate excited fluorine radicals which etch the inner surface. The plasma of organosilicone monomer in the glass capillary yields a uniform polymerized film on the inner surface. The resultant material functions as a good stationary phase for glass capillary gas chromatography (GC2). The inner surfaces treated with such a plasma, can be studied by means of a scanning electron microscope (SEM). The flexibility of this method permits the use of various stationary phases and surface modification.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 2 (1979), S. 416-422 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; SECAT-technique=stepless fine tuning of capillary selectivity by serial column temperature optimization ; Exponential influence of temperature on selectivity over a wide range found ; SECAT-technique ready for automation of column adjustment on sample composition polarity ; Instrumental and methodological details for primitive self made solution given ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: GC, including capillary GC, is rather inflexible, if a certain column length and stationary phase has been fixed for a given analytical problem. If the sample composition changes, one often has to change the column length and/or stationary phase, at least when something like optimum analytical conditions are needed. Temperature changes (or heating rates) can change the selectivity of a given column only within very limited ranges, due to the exponential effect of temperature on retention time. By serial coupling two chemically different capillaries, each run at another temperature, even the slightest changes of these two temperature values have a dramatic effect on the selectivity of the system for polar substances. We call this technique the SECAT mode of GC. Results are reported as retention index shifts, dependent on SECAT temperature data. This technique can in future easily be automated, thus enabling the analyst, for polar sample analysis, to adjust a given chroma-tographic system to his specific sample composition without touching the instrument.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 2 (1979), S. 487-496 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; Comparison of FID, ECD, FPD for detection limit. linearity, peak shape etc. ; Practical results for pesticide residue and coal hydrogenation products given ; Concentration dependent detectors in capillary GC interesting, when optimized ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A comparison of the characteristics and Performance of the flame ionization, electron capture, and flame photometric detectors with capillary columns is described. Factors which may affect the limits of detection, linearity, chromatographic peak shape, and other detector performance characteristics are discussed and compared with the results of a model derived for the behavior of concentration and mass flow-rate dependent chromatographic detectors used with capillary GC systems. Examples are given of highly complex and labile mixtures such as pesticide residues and products from coal hydrogenation.
    Additional Material: 13 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; Surface deactivation, persllylation ; Discussion of variable parameters ; Suggested practical procedure ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 11
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 2 (1979), S. 31-35 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; Surface deactivation, silylation ; Inertia stable to 350° ; Free acids and bases, simultaneous injection ; On-column injection ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A deactivation procedure is described based on a published method using hexamethyldisilazane in the gas phase. In addition to unusually high inertia and thermostability, the method produces truly neutral columns which allow simultaneous analysis of moderately strong free acids and bases. The silylated columns show their full potential only with on-column injection. Preliminary experimental directions are given; more elaborate directions will become available after extended optimization work.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 12
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 2 (1979), S. 187-188 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; Whiskers, OV-17 ; Steroid profiling ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 13
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 2 (1979), S. 189-190 
    ISSN: 0935-6304
    Keywords: Gas Chromatography ; Capillary, glass ; Tin-selective FPD ; Triphenyltin hydroxide ; TPTH ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A new method for the determination of triphenyltin hydroxide using capillary column gas chromatography with a tin-selective flame photometric detector has been developed. Triphenyltin hydroxide and its potential metabolites are converted to methyl derivatives and separated on glass capillary columns coated with OV-101. Derivatization of triphenyltin hydroxide, triphenyltin chloride, diphenyltin dichloride, phenyltin trichloride, and bis-triphenyltin oxide is nearly quantitative with a minimum of redistribution products. The selectivity of the flame photometric detector is cearly demonstrated by the comparison of chromatographic profiles obtained from using both the flame photometric and flame ionization detectors.The use of this chromatographic system in the analysis of triphenyltin hydroxide in a fortified water sample demonstrates the potential use of this system in organotin residue chemistry.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 14
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 2 (1979), S. 357-360 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; Whisker production ; Violent explosion at the „ether etching“ step ; Modification of pyrex glass etching leads to more uniform whiskers in size and shaep, simple, safe ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Recent attempts to reproduce a literature method for etching of Pyrex glass capillary columns with „etching ether“ resulted in reduction of the columns to dust through a violent explosion. Although modifications of the method produced etched columns, we found that less than satisfactory results were achieved. Introduction of etching ether by simply coating the column with a thin film of the ether produced an evenly etched column with well defined whiskers. Several observations made during the etching process will also be discussed.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 15
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 2 (1979), S. 361-365 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; Sample preparation by pre-chromatographic reaction at the 7 microliter level ; Reproducibility of methylation and allylation of barbiturates ; Application to blood analysis ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Pre-chromatographic reactions are no longer a necessary evil. Equipment such as the microrefluxer now allows reproducible 7-μl-reactions to be carried out in a short time. Thus multiple derivatisations can be used together with glass capillary GC for routine identifications. The method has been succesfully applied to barbiturates. Retention data of their methyl-, allyl- and benzyl-derivatives are given.Quantitative blood level determinations are briefly discussed.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 16
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 2 (1979), S. 411-415 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; Enantiomer amino acids separated on chirally functionalized polysiloxane phase ; McReynolds constants of chiral phase given ; HCl gas pretreatment, colloidal silicic acid deposition best wall preparation ; Racemisation tested ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Glass capillaries coated with Chirasil-Val, a chirally functionalised polysiloxane, are capable in principle of resolving all protein amino-acid enantiomers in a single run and within a short analysis time, thus allowing for example the quantitative amino acid determination by enantiomer labelling. The elution characteristics of the individual amino acids however are also dependent upon the chemical nature of the capillary wall surface, and a surface pretreatment is found to be necessary if all protein amino acids are to be analysed. Of the various methods of pretreatment tested, etching of borosilicate glass with gaseous HCl followed by deposition of colloidal silicic acid is considered to be the most suitable.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 17
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 2 (1979), S. 436-440 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; „bo“ data (starting peak width) in valveless multidimensional operation studied ; Heart cutting, trapping, re-injection effects measured ; Band broadening caused by connections small (160 ms2) ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: In order to permit valveless MDSS operation and easy column change, the hardware designed contains several connections. These can give rise to extra-column band broadening effects. In order to quantitate such effects, the packed-capillary column configuration (without trap) was used. The band broadening caused by the connections was found to be small: 120 ms2. A more practical approach was used to check the performance of the trap (re-injection) in the capillary-trap-capillary column configuration. Here the results obtained with re-injection from the trap were compared with results obtained in transfer and heart-cutting modes while the trap was heated. Re-injection was tested with n-alkanes ranging from n-C6 to n-C28. A starting peak width of 1.6 s was found.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 18
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 2 (1979), S. 461-474 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; Limitations by temperature, in trace analysis, by irreversible adsorption ; Sample capacity, separation efficiency ; Multidimensional GC advantageous ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Glass capillary gas chromatography is a high resolution separation method which allows the qualitative and quantitative analysis of even complex mixtures, which may contain many components-also isomeric-in a wide range of volatilities, polarities and concentrations.The principal limitation of gas chromatographic application is given by an insufficient volatility of the species to be separated. Elevated temperatures have to be applied if the application range is to be extended and to achieve steep peak profiles, i.e. low detection limits at high resolution. The use of elevated temperatures is limited, of course, by the temperature stability of both the solvent (stationary liquid and support) and the solutes.The problems of trace analysis for low volatility compounds at high resolution and its limitational parameters regarding sampling, separation and detection are discussed.The applicability of glass capillary columns in this field is influenced by the following parameters: tailing behaviour; irreversible adsorption of polar and decomposition of unstable solutes; thermal stability of stationary liquid (including the support deactivation); separation efficiency and sample capacity (film thickness).Multidimensional gas chromatography using capillary columns coupled either with a packed or another capilllary column for preseparations may be applied with advantage in the analysis of complex mixtures.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 19
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 2 (1979), S. 527-528 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; Leaching compared to etching ; Leaching by 20% HCI at 240°C ; Metal ions eliminated from glass surface ; Silica layer formed on leached surface ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 20
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 2 (1979), S. 712-714 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; Cholesteric liquid crystal phase ; Separation of geometrical isomers ; Cholesteryl cinnamate ; Insect pheromones ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 21
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 2 (1979), S. 22-26 
    ISSN: 0935-6304
    Keywords: Gas Chromatography ; Capillary, glass ; Environmental specific trace analysis ; FID/ECD response ratios for PNA's ; PNA identification evidently improved ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The possibility of simultaneous application of an electron capture (ECD) and a flame ionization detector (FID) connected to a glass capillary column for analyzing polynuclear aromatic hydrocarbons (PNA) has been investigated. The ECD/FID ratio is determined for 46 PNA compounds. The ratios vary from 0.02 to 117 with relative standard deviations better than 20 percent determined from 10 replicate analyses. The results suggest that the method may be used for obtaining additional evidence in identifying PNA in environmental samples.Impurities and transformation products in the standard were identified by computerized glass capillary gas chromatography/mass spectrometry. Quinones and diones are responsible for the high EC-response determined in some trace components in the standard.An application of the method is shown for PNA from particulates in urban atmospheres.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 22
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 2 (1979), S. 303-311 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; Overview, preparation and evaluation techniques ; Quantitation is the least satisfactory aspect of (GC)2 ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The preparation of (glass) capillary columns of high quality is still not without difficulties. Six problems in this context are highlighted. Column material choice(l), glass wall modification(2) and coating(3) are considered to have reached a satisfactory level. Deactivation(4) is still in a state of flux. Quantitation(5) is the least satisfactory aspect of capillary GC. Scope expansion(6) will be helped by the introduction of new phases of high thermal stability and by the adoption of solutions exclusively applicable to capillary GC.Evaluation of (glass) capillary GC columns is a rapidly developing field. Hopefully the number and complexity of test or polarity mixtures will not expand much further and it will be possible to make a clear and generally acceptable choice.The preparation and evaluation of ever-improving capillary columns is important to an ever-widening group of chromatographers. Our opinion on selected topics in this already vast field is summarized in the following overview.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 23
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 2 (1979), S. 75-76 
    ISSN: 0935-6304
    Keywords: Gas Chromatography ; Capillary, glass ; KI of monoterpenes ; SE-30, Carbowax 20M ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 24
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 2 (1979), S. 405-410 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; Stationary phases of polysiloxane-type degrade in acidic solution ; Several salt traces affect stability at high temperature NaCl on Duran-5O: no effect at 260°C ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A number of polysiloxanes have been shown to be sensitive to acids when dissolved in chloroform.At 26O°C polysiloxanes were found to degrade under the influence of several compounds used or produced during the preparation of glass capillary columns.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 25
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 2 (1979), S. 249-250 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; Deactivation stable up to 35O°C ; High temperature phase ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A method of deactivating the inner surface of glass capillary columns is described, which can be used at 350°C without detoriation. A non-polar liquid phase was prepared from a commercially available liquid phase which, when coated on a glass surface, can withstand temperatures of 325°C for isothermal analysis and 350°C for temperature-programmed analysis.After deactivation, the column was coated using the static coating method. Then it was conditioned, tested and kept for 48 hours at 35O°C before being used for the analysis of a mixture of chlorinated pesticides.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 26
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 2 (1979), S. 378-384 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; Glass capillaries for low volatile polar natural products analysis ; Application to N-TFA-dipeptide, TMS-ribose, TMS-manno-samin, peptide sequence analysis ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Two published procedures for glass capillary column production are applied to produce capillaries for chromatography of polar natural compounds. Soda lime glass capillaries, after leaching with aqueous HCL, are either treated with colloidal silicic acid or with barium carbonate and coated with either Silar 7CP or SE 52. A test mixture as well as polar carbohydrate and peptide mixtures are chromatographed on the different columns and their chromatographic properties are evaluated. Combined capillary gas chromatography-electron impact and chemical ionization mass spectrometry are used for identification of the peptide sequence.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 27
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 2 (1979), S. 481-486 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; Splitting conditions for quantitative sampling investigated ; Injection amount and temperature should remain constant ; Standard deviation below 1% ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Sample inlet splitters are used in capillary column gas chromatography. We have investigated the sample band broadening in the splitter and studied reproducibility and accuracy in quantitative analysis using a simple lab-made splitter. It was found that the results were dependent upon the operating conditions such as split ratio, splitter temperature, glass wool plug, injected sample volume and solvent.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 28
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 2 (1979), S. 441-443 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; Methodological and instrumental solution of the recirculation problem ; In-line miniature switching valves used ; Column length optimization possible ; Over 3500 theoretical plates per second generated ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A multiple repass system, utilizing an in-line switching valve and suitable for use with small-bore glass open tubular columns, is described. The advantages of the system, which include higher OPGV, large plate numbers and optimization of column “length”, are discussed.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 29
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 2 (1979), S. 475-480 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; Photoionization detector (PID) ; Detection limit 50 to 100 pg nitrosamines at 10.2 eV ; Nitrosamine analysis ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The use of a photoionization detector (PID) coupled to a glass capillary gas chromatography (GC2) separation system for the detection of carcinogenic nitrosamines was investigated. The components analyzed gave a linear response with a lower detection limit of 50 to 100 pg with the 10.2 eV ionization source. No detector response was obtained with an ionization energy of 9.5 eV.Chromatography of meat extracts indicated their complex molecular composition. Simple liquid chromatographic cleaning procedures significantly decreased the complexity of these samples, but not sufficiently for the accurate quantition of nitrosamine components.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 30
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 2 (1979), S. 675-676 
    ISSN: 0935-6304
    Keywords: Triglycerides ; GC/MS of triglycerides ; Capillary, glass ; All-glass GC/MS interface ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 31
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 2 (1979), S. 715-719 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; Sample introduction ; Direct manual operation at the capillary inlet ; Micro pipette is coupled onto cold separation capillary ; PTFE connection used ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 32
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; Separation of polychloro biphenyls ; Separation of organochlorine pesticides ; Splitless automated injection ; Residue level ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Complicated PCB mixtures can be separated in individual compounds using glass capillary gas chromatography, (GC)2. Depending on extraction and clean-up procedure it is also possible to separate and determine organochlorine pesticides at the same time.This (GC)2 technique can be used to determine the contents of individual chlorinated biphenyls in milk products and animal feedstuffs and in the analysis of complicated extracts of soil and vegetable material.Practical aspects concerning connection of the capillary, automatic splitless injection, repeatability of the retention time, quality of the column with respect to separation and adsorption and degradation of DDT are discussed.The detection of individual chlorinated biphenyls is possible at the ppb level in fats and vegetable materials, using an extraction and clean-up procedure, based on saponification of the sample.Preliminary results for milk, obtained from several areas, are shown.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 33
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 2 (1979), S. 746-748 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; Pt/Ir tubing ; Interfacing and coupling of columns ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 34
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 2 (1979), S. 43-44 
    ISSN: 0935-6304
    Keywords: Gas Chromatography ; Capillary, glass ; Fatty acid methyl esters structure analysis ; On-line hydrogenation, platinum catalyst precolumn ; 10-8ϕ in complicated natural mixtures ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: An injection splitter in front of a glass capillary column was used for the hydrogenation of fatty acid methyl esters (FAME) mixtures. Hydrogenation followed by gas chromatographic analysis on capillary columns permitted detection and identification in complicated natural mixtures of branched fatty acids, showing minor structural differences, in quantities down to 10-8g.The technique described, apart from its suitability for FAME analysis, shows promise for structure determination studies of other classes of compounds.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 35
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 2 (1979), S. 312-318 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; Subnanogram analysis of estrogens as heptafluorobutyric esters ; ECD, quantitative analysis, automatic injection ; Run-to-run precision at the 50 picogram level between 2 and 7% rel. standard deviation ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Subnanogram detection of steroids has become increasingly important today. One applicable method for gas chromatographic determination of subnanogram quantities of estrogens as halogenated derivatives is electron capture detection. HFB-derivatives of 7 different estrogens were automatically injected onto a prolonged narrow bore wall-coated glass capillary column. Normal split injection could not be used for this trace analysis because of too much loss of sample. Only small amounts of sample were available from which double analysis had to be performed.Cross-contamination of the automatic sampling system as well as precision of retention times and peak areas were determined.The type of injection described showed better quantitative results compared to the splitless injection technique.All details of the system used together with the results are this discussed in this paper.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 36
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 2 (1979), S. 343-350 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; Analysis up to C50 in GC/quadrupole MS combination ; No special procedures necessary when using commercially available instruments ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The analysis of low volatile compounds by (GC)2/MS using high-temperature stable glass-capillary columns and a commercially available GC/quadrupole MS instrument is described.It will be shown that no special modifications or procedures are required in analyzing organic compounds exceeding carbon numbers of 50. The application to industrially and naturally occuring high boiling mixtures will be discussed.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 37
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 2 (1979), S. 351-356 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; Potash soda lead and fused silica as wall material investigated ; Thin-walled fused silica is an ideal material ; Inherently more inert than normal glass ; High flexibility avoids fragility problems ; Application examples (alcohols, mercaptanes, sulfides, phenolsamines, acids) ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: An investigation was conducted of various glasses, other than soda lime or borosilicate, for use in glass capillary gas chromatography. The work has uncovered some unique chromatographic qualities in the use of potash soda lead and fused silica glasses as materials for making glass capillary columns. The fused silica proved to be an ideal material for capillary column construction, being inherently more inert than glass containing metal oxides. It has been shown that through the use of thin wall capillary tubing of high flexibility many of the mechanical problems associated with glass capillary columns, such as fragility and column straightening, can be avoided.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 38
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 2 (1979), S. 371-377 
    ISSN: 0935-6304
    Keywords: Liquid chromatography, HPLC ; Capillary, glass ; Review on open tubular micro capillary LC ; Technical solutions of the problems in zero dead volume connections ; Capillary LC/MS combination ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Capillary columns in gas chromatography, first proposed by Golay [1,2], have become well established [3] which have extremely high column efficiencies and separabilities. Everyone could imagine it to be a great tool if such a kind of high efficiency column could be established in liquid chromatography (LC). Microcapillary liquid chromatography (MCLC) may be one way of achieving high-efficiency in terms of theoretical plates. Few papers were published in this field before 1976 [4-6], but more recently, after 1977 [7-15], this field has become one of topical interest in liquid chromatography. Temporarily there are two microcapillary liquid chromatography, that is: „open-tubular“ [7,8,10-15] and „packed“ [9] MCLC. In this presentation we focus on open-tubular microcapillary liquid chromatography and a review contemporary developments of ours and others.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 39
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 2 (1979), S. 366-370 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; Sampling problems by syringe needle temperature ; Technical solution of the problems by cooling and heating up minimized masses ; Discrimination and standard deviation measured with test mixtures C18-C38 ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: On-column injection into a hot gas chromatograph oven involves the danger that the bottom part of the needle is warmed up above the boiling point of the solvent in the sample. Consequently parts of the sample are evaporated out of the needle instead of being introduced as a liquid into the capillary column. This causes losses and hence discrimination of the less volatile parts of the sample which remain in the needle.A technical solution is proposed using a system for cooling the capillary during the injection, down to the injection point in the oven.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 40
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; Surface roughening by direct deposition of suspension particles ; NaCl used ; High reproducibility when coated with polar phases ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A method is described for roughening the surface of glass capillary columns for subsequent coating with polar stationary phases. A suspension of sodium chloride, obtained by addition of a saturated solution of sodium chloride in methanol to 1,1,1-trichloroethane, is passed through the column at velocities of 1-5 cm/s. During passage of the suspension, particles of sodium chloride deposit spontaneously on the column wall. The amount of sodium chloride deposited on the column wall is a function of the volume of the suspension passed through and of the contact time of the suspension and the column wall. Ultimately the amount of sodium chloride per unit surface area approaches a maximum. Columns covered with this maximum amount of sodium chloride were prepared with high reproducibility and coated with a number of polar stationary phases. Various factors that influence the stability of the suspension and the deposition of sodium chloride are discussed and minimum requirements are given. A theoretical model is proposed for the mechanism of deposition of sodium chloride particles on the glass wall.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 41
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 2 (1979), S. 251-252 
    ISSN: 0935-6304
    Keywords: Gas Chromatography ; Capillary, glass ; GC capillary life time ; Diagnosis of problems caused by dirt at inlet ; How to inspect and repair capillary inlets ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 42
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 2 (1979), S. 329-334 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; Theory ; Systematic treatment of simplification effects on minimum plate height and optimum carrier gas velocity ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Band broadening in capillary columns is satisfactorily described by the Golay-equation extended to situations of appreciable pressure drop by Giddings. In practice, however, several simplifications are often made. The effect of these simplifications on the calculated values of the minimum plate height and optimum carrier gas velocity are treated systematically.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 43
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 2 (1979), S. 335-342 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; Two-dimensional technique ; Critical evaluation of individual instrumental components ; Minimization of extra column effects and operational parameters discussed ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A versatile two-dimensional gas chromatograph is described, consisting of 2 separate ovens, one intermediate trap, an auxiliary inlet, and the necessary hardware to effect off-line switching according to the principle of Deans. The unit has been designed for use with high resolution glass capillary columns. The performance of individual instrumental components was critically evaluated. Results showed that low dead volume glass to metal connections were required in the manifold and detector lines to minimize extra-column effects. The mass of the intermediate trap must be low to allow rapid heating. Operational parameters are discussed and examples of some applications are shown.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 44
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 2 (1979), S. 395-399 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; Retention index determination, reproducibility and error propagation ; Retention time measurement of ±0.01% necessary for retention index reproducibility of ±0.05 units ; Error propagation calculation program for pocket calculator given (HP 67) ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Precise evaluation of the chromatographic data by means of the relative retention will allow the full use of the resolution achieved by capillary columns. In practice, retention-index determination is best suited for this purpose. The reproducibility of retention-index determination strongly depends, among other factors, on the accuracy of retention time measurement. A reproducibility of ±0,05 i.u. can be easily achieved with modern gas chromatographic equipment, provided the retention times can be measured with an accuracy of at least ±0.01%. This can be shown by error propagation analysis of retention-index calculation performed with the aid of a programmable pocket calculator.
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 45
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; Organic gas phase cigarette smoke ; Microprocessor-controlled ; Cryogenic preconcentration trap ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: An automatic injection system for the analysis of gas phase smoke has been designed and evaluated using the microprocessor-controlled Hewlett-Packard 5830 gas chromatograph. The cryogenic preconcentration trap was constructed from relatively inexpensive and readily available materials. It was determined that the use of the preconcentration trap, as opposed to condensing the smoke on the head of the cold (-50°C) chromatographic column, significantly enhanced the resolution of the more volatile gas phase components. Data are presented which illustrate the injection system characteristics. In addition, chromatograms of gas phase smoke are presented which demonstrate the effectiveness of this technique.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...