ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Analytical Chemistry and Spectroscopy  (1,583)
  • Wiley-Blackwell  (1,583)
  • American Physical Society
  • 1995-1999
  • 1980-1984  (849)
  • 1975-1979  (734)
  • 1925-1929
  • 1980  (849)
  • 1978  (734)
Collection
Publisher
  • Wiley-Blackwell  (1,583)
  • American Physical Society
Years
  • 1995-1999
  • 1980-1984  (849)
  • 1975-1979  (734)
  • 1925-1929
Year
  • 1
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 1 (1978), S. 85-90 
    ISSN: 0935-6304
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Basic methodology to effect the separation of complex samples by gas chromatography is discussed from an experimental point of view. Several possibilities are presented which are commonly used to enhance the information content of a gas chromatographic run. These include incorporation of more than one set of retention data, multiple detectors, and special column switching techniques. These and other techniques have sometimes been labeled “multidimensional” in the literature. An attempt is made to define the term “two-dimensional chromatography”.The review is divided into sections which point out the different directions which have been taken to deconvolute chromatographically unresolved components. Particular emphasis is placed on technology which is capable of dealing with samples of extreme complexity, and instrumentation for trace- and ultratrace analysis is dicussed with specific examples. The future of two-dimensional techniques in gas chromatography is looked into.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 1 (1978), S. 92-92 
    ISSN: 0935-6304
    Keywords: Gas Chromatography ; Capillary, glass ; Plugs for static coating procedure ; Advantages over sodium silicate setting plugs ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 1 (1978), S. 93-94 
    ISSN: 0935-6304
    Keywords: Gas Chromatography ; Capillary, glass ; Static coating, apolar gums ; Pentane better than methylene chloride, ready in 8 hours ; (20 m, 0.3 mm i.d.) ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 1 (1978), S. 94-95 
    ISSN: 0935-6304
    Keywords: Gas Chromatography ; Capillary, glass ; Quantitative analysis of unsaturated fatty methyl esters ; Remarkable systematic errors of cis/trans determination ; Errors depend on phases chosen ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 1 (1978), S. 97-97 
    ISSN: 0935-6304
    Keywords: Liquid Chromatography ; Structure and relation of polyhalogenated aromatics ; discussed ; Silica gel/aluminium oxide compared ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    ISSN: 0935-6304
    Keywords: Selective derivatization reagent for HPLC, HPTLC, TLC ; Fluorescence introducing phenanthreneboronic acid ; Stability of chromatographic derivatives studies. ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 1 (1978), S. 100-101 
    ISSN: 0935-6304
    Keywords: Liquid Chromatography HPLC ; Trace determination of Histamine in wine at 0.2 ng/I level ; DANS derivatization ; Selective, no interference by amino acids etc ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 1 (1978), S. 98-99 
    ISSN: 0935-6304
    Keywords: Gas Chromatography ; Capillary, glass ; Quantitative analysis of higher alcohols ; Direct injection of beverages, liqueurs etc ; Inner standard dioxan, inlet modification ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 1 (1978), S. 101-102 
    ISSN: 0935-6304
    Keywords: Gas Chromatography ; Glass capillary drawing machine ; Improvements for constant inner diameter production ; 0.3 mm i.d. at least ± 1.5% precision ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 1 (1978), S. 103-104 
    ISSN: 0935-6304
    Keywords: Gas Chromatography ; Capillary, glass ; Fittings, remaining elastic till 300°C ; Important details of proper handling ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 11
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 1 (1978), S. 105-106 
    ISSN: 0935-6304
    Keywords: Thin Layer Chromatography, HPTLC ; Quantitative analysis of anticonvulsant drugs extracted from plasma ; Sample volume needed equals 2 microliter plasma ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 12
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 1 (1978), S. 106-108 
    ISSN: 0935-6304
    Keywords: Thin Layer Chromatography HPTLC ; Quantitative analysis of feedstuff ingredients ; Comparison HPTLC-TLC layer materials ; HPTLC has advantages over TLC ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 13
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 1 (1978), S. 111-111 
    ISSN: 0935-6304
    Keywords: gas chromatography ; stationary phases ; properties ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 14
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 1 (1978), S. 113-114 
    ISSN: 0935-6304
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 15
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 1 (1978), S. 115-120 
    ISSN: 0935-6304
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 16
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 1 (1978), S. 137-137 
    ISSN: 0935-6304
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 17
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 1 (1978), S. 139-142 
    ISSN: 0935-6304
    Keywords: Gas Chromatography ; Capillary, glass ; Hydrocarbon cut, optimized separation ; Capillary preparation for ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Techniques have been developed for the rapid separation (about 20 minutes) of the 39 compounds in crude petroleums, or petroleum distillates, which boil between 28 and 114°C. A 300 meter glass column (0.25 mm i.d.) which is etched, coated with a mixture of normal hexadecane and Kel-F10157 is utilized to perform this separation at room temperature. The separations obtained with this non-polar liquid mixture and the «inert» glass surface are much more rapid than those previously obtained with stainless steel capillary columns.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 18
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 1 (1978), S. 143-148 
    ISSN: 0935-6304
    Keywords: Gas Chromatography ; Capillary glass ; Tailor-made by graphitized carbon black precoating ; Application to pesticides, terpenes, aromatic hydrocarbons, free fatty acids ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The performance of graphitized glass capillary columns obtained by precoating the inner glass walls with graphitized carbon black has been evaluated. It has been shown that according to the amount of stationary phase coated such columns can operate in gas-liquid-solid chromatography and in gas-liquid chromatography so that tailor-made columns for specific separations can be prepared. The versatility of these columns is shown in the separation of various mixtures (terpenes, pesticides, isomeric species and others) of analytical importance.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 19
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 1 (1978), S. 156-160 
    ISSN: 0935-6304
    Keywords: Thin Layer Chromatography, TLC and HPTLC ; Quantitative evaluation ; Errors, systematic and statistical, error propagation by graphical methods ; Peak height gives better results (slow scanning) ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The paper discusses errors and error propagation in respect of graphic methods in quantitative in situ measurements in TLC. An error of 0.3% is possible by measuring only peak height if optimal conditions are chosen. This is in good agreement with analysis done practically which gives errors in the order of 0.3-0.6%. If the peak area is evaluated using the approximation peak height × half width, the error is in the order of 0.6%, but in real experiments only 1.5% had been found. Systematic errors in determining peak heights are introduced by the time constant of the amplifiers and the recorder.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 20
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 1 (1978), S. 149-155 
    ISSN: 0935-6304
    Keywords: Gas Chromatography ; Capillary, glass ; Preparation of apolar columns ; Ba CO3 procedure optimized for thermostability acid/base behaviour and efficiency ; New, quantitative testing procedure ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: As an extension of previous reports, the barium carbonate procedure has been optimized in detail for the preparation of apolar columns. The aim was to produce optimum overall column characteristics, and to maintain them unchanged under the prolonged influence of the highest possible temperature. The main parameters under optimization were glass variety, leaching of glass surface with aqueous HCl, and amount of barium carbonate deposited, while deactivation and coating were kept constant. The basic column characteristics were adsorption properties and thermostability of deactivation, acid/base behaviour and separation efficiency. They were determined by a new, quantitative testing procedure. Intense leaching was able to eliminate almost totally the differences between glass varieties and to create a well-defined glass surface. While untreated glass, leached glass, and barium carbonate treated glass showed specific weak points in the respective column quality, the combination of leaching and barium carbonate treatment yielded the highest and most stable quality. Some technical modifications of the preparation procedure are described, including deactivation in the gas phase, and use of pentane as a solvent for static coating.
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 21
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 1 (1978), S. 277-277 
    ISSN: 0935-6304
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 22
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 1 (1978), S. 275-276 
    ISSN: 0935-6304
    Keywords: Gas Chromatography ; Capillary ; Splitless injection ; Theoretical basis for reconcetration by solvent effects ; Guidelines for an effective solvent effect, in literature citation ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 23
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 1 (1978), S. 306-307 
    ISSN: 0935-6304
    Keywords: Gas Chromatography ; calculation of sample size ; simplest formula ; any type of GC column used ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 1 Tab.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 24
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 1 (1978), S. 307-308 
    ISSN: 0935-6304
    Keywords: Gas Chromatography ; capillary, glass, diagnosis of damage ; repair by partial washing ; partial reimpregnation/deactivation ; repair test ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 25
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 1 (1978), S. 309-310 
    ISSN: 0935-6304
    Keywords: Thin Layer Chromatography, TLC ; Reversed phase, chemically bonded C18/CH3OH, H2O, NaCl ; quantitative caffein densitometry at the 7% CV level, 1.2 microgram ; 12-70 min development time ; Aspirin, caffein, phenacetin separated ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 26
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 1 (1978), S. 311-312 
    ISSN: 0935-6304
    Keywords: Thin-Layer Chromatography, HPTLC ; Linoleic acid ; Lipid peroxidation ; Malondialdehyde ; Thiobarbituric acid test ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Peroxidised linoleic acid reacts with acidified thiobarbituric acid to give a chromogen absorbing maximally at 532 nm. This TBA reactant is chromatographically identical to the TBA-MDA adduct formed from linolenic acid and a pure MDA standard. Considerably less MDA is produced by peroxidised linoleic acid compared to that formed from linolenic acid. In this respect the type of acid used for the colour reaction appears to be important.
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 27
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 1 (1978), S. 313-313 
    ISSN: 0935-6304
    Keywords: Thin Layer Chromatography, TLC ; Ion exchange resin plates/tert. butyl alcohol, H2O, Na2HPO4, NaCl ; Nebramicin, components, qualitative analysis ; 7 hours development time ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A thin-layer chromatographic method on chromatoplates coated with Dowex 50 × 8 ion-exchange resin, suitable for the separation of 5 nebramycin components, was developed.
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 28
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 1 (1978), S. 314-314 
    ISSN: 0935-6304
    Keywords: Thin Layer Chromatography, TLC ; Silicagel/org. solvents mixture ; semiquantiative determination of Ru, Rh, Pd, Ir, Pt, Au ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 1 Tab.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 29
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 1 (1978), S. 315-317 
    ISSN: 0935-6304
    Keywords: Thin Layer Chromatography, HPTLC ; Quantitation, fully instrumentalized, automated, in-situ ; Mechanical precision required for positioning of plate center ; circulare miniaturized technique, standard deviation s = ± 1.1-1.8% of 100 ng benzodiazepines ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 30
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 1 (1978), S. 319-320 
    ISSN: 0935-6304
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 31
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 1 (1978), S. 321-326 
    ISSN: 0935-6304
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 32
    ISSN: 0935-6304
    Keywords: Liquid chromatography, HPLC, instrumental details ; Column terminator ; Efficient intermediate preparative liquid chromatography ; Packing of angular silica 5μ and 2-10μ ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A comparison is made between a flat bottom column terminator and a cone terminator on. 1.27 cm O.D. and 2.54 cm O.D. columns. The cone terminator results in a doubling of the column efficiency, is simple and inexpensive, and is universally adaptable to any diameter column.
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 33
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 1 (1978), S. 327-329 
    ISSN: 0935-6304
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 34
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 1 (1978), S. 161-163 
    ISSN: 0935-6304
    Keywords: Thin Layer Chromatography, HPTLC ; Qualitative evaluation ; Precise Rf determination by U-chamber, technique, ±1% ; Comparison of calculated and measured values ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Correlation between chemical structure and Rf-values was studied in the case of aniline and its derivatives using high performance TLC and a U-chamber. The characteristic group constants referring to each substituent were determined by chromatographing derivatives with one substituent and aniline in toluene and dibutyl ether respectively. On the basis of these constants the RM and Rf values of derivatives with more substituents were calculated. Comparing the calculated and measured values good agreement was found.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 35
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 1 (1978), S. 169-170 
    ISSN: 0935-6304
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 36
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 1 (1978), S. 164-168 
    ISSN: 0935-6304
    Keywords: Thin Layer Chromatography, HPTLC ; Fastest possible analytical mode: Anticircular separation ; First principal analytical details ; Most economical TLC/HPTLC technique, quantitative comparison with linear and circular mode ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The principal analytical details for the third of three possible modes in high performance thin-layer chromatography are given, namely the anticircular mode. Separation is achieved by allowing the mobile phase to enter the plate layer on a precise outer circle line, from where it flows towards the centre with nearly constant speed. This technique is theoretically and practically the fastest of all three possible in HPTLC. It permits maximum sample capacity with a minimum of time, layer and mobile phase consumption. It is therefore the most economical HPTLC technique.A new carrier-free mobile phase transfer principle is used. The conditions for qualitative and quantitative analysis are good: repeatability, reproducibility and accuracy of routine TLC analyses are superior to those achieved by the classical trough technique. The specially narrow spot-path in anticircular HPTLC facilitates automated quantitation. Compared with the linear and circular modes, the anticircular mode shows better separation and significantly increased sensitivity at higher Rf-values. The drawback, however, is that the separation power (expressed by the separation number) is lower compared with the other two modes.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 37
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 1 (1978), S. 171-172 
    ISSN: 0935-6304
    Keywords: Chromatography, LLC ; High speed, high resolution by toroidal distribution in two phase polymer systems ; Separation of cells and cell organelles ; NaCl gradient for E. coli separations ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 38
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 1 (1978), S. 173-174 
    ISSN: 0935-6304
    Keywords: Instrumentation in GC ; Pressure regulators in capillary GC ; Diffusion free, optimal with 0.03 mm thick steel foil ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 39
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 3 (1980), S. 151-151 
    ISSN: 0935-6304
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 40
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 1 (1978), S. 200-201 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Control of relative retention in series-coupled columns by temperature variation ; Effect of temperature variation on OV 101/Silar 5 column pair ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 41
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 1 (1978), S. 201-202 
    ISSN: 0935-6304
    Keywords: Gas Chromatography ; Micropacked columns ; Series-coupled ; Polarity change by temperature variation ; Temperatures independently varied in each column ; Retention index data for study of microprocessor-controlled resolution optimization ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 1 Tab.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 42
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 1 (1978), S. 205-206 
    ISSN: 0935-6304
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 43
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 3 (1980), S. 248-252 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Column loadability - overload phenomenon ; Non-classical approach to theory of loadability ; Effect on retention times, peak shape ; Effect of column length ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The usual concepts of the dynamics of an overloaded solute band fail to explain several phenomena such as the typical “leading-tail” shape and retention deviations exhibited by overloaded peaks, and why these defects are more commonly observed in short columns. These and other related deviations from theory can be rationalized by a non-classical approach to the overloading phenomenon.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 44
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 3 (1980), S. 257-260 
    ISSN: 0935-6304
    Keywords: Liquid adsorption chromatography, LSC, LC ; LC with binary mobile phase ; Solute-solvent association ; Solvent-solvent association ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Analytical equations for the capacity ratio in liquid adsorption chromatography with a binary mobile phase, involving solute-solvent and solvent-solvent association in the mobile and surface phases, have been derived. Very simple equations have been obtained for higher values of mole fraction of the more efficient eluting solvent.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 45
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 3 (1980), S. 265-265 
    ISSN: 0935-6304
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 46
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 3 (1980), S. 286-290 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary ; Discrimination due to FID ; Effect of carrier gas flow changes on detector sensitivity ; Hydrogen as carrier gas ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The sensitivity of an FID may change when the carrier gas flow rate changes during a chromatographic run. Sample parts which are eluted at reduced FID sensitivity produce a reduced peak area, hence are discriminated as compared to other components. Sensitivity changes were studied for hydrogen as carrier gas. For the detector tested, differences in the carrier gas flow rates of 1 ml/min shifted the FID sensitivity by 1 to 5% (depending on the fuel gas supply). Thus the stability of the sensitivity is no longer ensured as soon as the carrier gas flow rate is changed manually or by an automatic programmer during an analysis. Sensitivity drifts may also occur during temperature programmed runs with a pressure regulated carrier gas supply since the gas flow through the capillary drops with increasing temperature. Such shifts in the response became noticeable as soon as relatively high carrier gas flow rates combined with long range temperature programmes were used. The typical patterns of such discriminations are shown, closing with a discussion on the possibilities for minimizing such undesired effects.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 47
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 3 (1980), S. 301-302 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Polychlorinated biphenyls ; Liquid crystal phase ; Choice of stationary phases for analysis ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 2 Tab.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 48
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 3 (1980), S. 305-306 
    ISSN: 0935-6304
    Keywords: Liquid chromatography, micro HPLC ; Temperature effect ; Cooled column ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 49
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 3 (1980), S. 337-344 
    ISSN: 0935-6304
    Keywords: Gas Chromatography ; Capillary, glass ; Surface deactivation ; High temperature silylation ; Applications ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: This paper describes the results of a study on the deactivation of the surface of glass capillary columns by high temperature silylation (HTS). The different steps, leaching, washing, dehydration and HTS were optimized. A practical procedure yielding a high percentage of very good columns is given. The influence of leaching and HTS on the temperature stability and coating efficiency of capillary columns coated with OV-1 was studied. The inertness of the glass surface after HTS is demonstrated by several examples.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 50
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 3 (1980), S. 351-352 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Injector ; Concentrator ; Electrically heated inlet ; Capillary columns ; Vapor sampler ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 51
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 1 (1978), S. 229-230 
    ISSN: 0935-6304
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 52
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 1 (1978) 
    ISSN: 0935-6304
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 53
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 1 (1978), S. 236-237 
    ISSN: 0935-6304
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 54
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 1 (1978), S. 237-237 
    ISSN: 0935-6304
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 55
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 1 (1978), S. 235-235 
    ISSN: 0935-6304
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 56
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 3 (1980), S. 531-533 
    ISSN: 0935-6304
    Keywords: HPLC, fluorescence detection ; Chlorophyll A determination in marine phytoplankton ; Effect of mobile phase composition ; Interference from chlorophyll degradation products ; Interferences from carotenoids and xanthophylls ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 57
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 3 (1980), S. 537-544 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Chromatographic properties of glass surfaces ; Fluorad FC 431 ; Glass capillary GC of basic compounds ; Modification of glass surfaces ; Deactivation of glass surfaces ; Acid-base behaviour of GC columns ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: “Leaching” or “etching” by strong mineral acids seems to be a necessary pretreatment step for the most commonly used deactivation procedures of glass capillaries by reaction with either polyethylene glycol or silylation reagents. The acidic sites which are formed on the surface during this acid treatment cannot be completely removed by the subsequent deactivation process. This drawback can be overcome by performing the leaching with water vapour, resulting in an accumulation of cations at the surface and a decrease in the number of silanol groups. Capillaries of this type show excellent properties for the chromatography of strongly basic compounds. After the wash-out of the alkaline surface layer, the acidity of the support is suited for the chromatography of strongly basic as well as strongly acidic compounds. Due to a lack of reactive acidic sites, special deactivation procedures have to be applied to capillaries produced in this way.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 58
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 3 (1980), S. 583-584 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; (Fused silica) capillary columns ; Intermediate test ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 59
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 3 (1980), S. 575-582 
    ISSN: 0935-6304
    Keywords: Numerical examples ; Constant volume Varigrad ; Hydrostatic Varigrad ; Incremental method of gradient elution ; Modified incremental method ; Non-homogeneous Varigrad ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Part 2 deals with the application of the equations derived in Part 1 to the systematic calculations of the constant volume and hydrostatic Varigrads. Examples are given which illustrate the advantage of using the modified incremental method of gradient elution. The non-homogeneous Varigrad, where mixing chambers may vary in volume, is also treated.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 60
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 3 (1980), S. 589-590 
    ISSN: 0935-6304
    Keywords: Liquid chromatography, (HP)LC, CLC ; Capillary, fused silica with chemically bonded phases ; 30 μm i.d., split sampling ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 61
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 3 (1980), S. 592-592 
    ISSN: 0935-6304
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 62
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 3 (1980), S. 651-652 
    ISSN: 0935-6304
    Keywords: Thin-layer chromatography ; Monovalent anions ; Separation of Cl-, Br-, I-, NO3- and SCN- on a single chromatogram ; Developing solvents ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 1 Tab.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 63
    ISSN: 0935-6304
    Keywords: LC/MS interface ; Nebulizing interface ; Micro-LC ; CI-MS ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: An improved vacuum nebulizing interface with a very short counter nozzle was developed for direct coupling of a micro-LC and a quadrupole MS with CI-chamber. With the LC-MS system using the nebulizing interface, it became possible to take mass fragmentograms for various less volatile compounds such as glutamic acid, steroids, aromatic amines and chlorine-containing insecticides.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 64
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 3 (1980), S. 11-15 
    ISSN: 0935-6304
    Keywords: GC instrument conversion ; All-glass GC-2 system ; Phenols ; Hydrocarbons ; Terpenoids ; Linear response ; Reproducibility ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Two regular GC instruments were modified with injection port liners, split-mode injection systems, pressure regulators, effluent traps and needle valves to produce an all-glass GC-2 system. This simple and inexpensive system allows the quantitative analyses of phenols, hydrocarbons, acids, sterols, terpenoids, and alkaloids with excellent reproducibility and linear response. Even more impressive was its ability to analyze a C45-terpenoid alcohol, solanesol, as its TMS-derivative (M.W. 702).
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 65
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 3 (1980), S. 87-88 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, wide-bore glass WCOT ; Fourier Transform Infrared/glass capillary GC on-the-fly ; Coupling successful ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: By the use of a wide-bore WCOT capillary column, it was possible to obtain the first on-the-fly GC/FT-IR spectra with a WCOT column. This wide-bore WCOT column gave improved separation, as compared to a SCOT column, and yielded identifiable infrared spectra for a real sample.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 66
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 3 (1980), S. 93-94 
    ISSN: 0935-6304
    Keywords: Ion-Exchange TLC on resin coated chromatosheets ; Separation of biogenic amines ; Quantitation by video-densitometry ; Biogenic amines in foods and feeds ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 67
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 3 (1980) 
    ISSN: 0935-6304
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 68
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 3 (1980), S. 124-128 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Series-coupled chemically differing columns ; Fundamental studies on the properties for basic theory started ; Retention time and separation efficiency ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Basic expressions are derived for both the retention time and the effective separation factor in serially coupled GC columns. The retention time is determined by two main parameters. The first is the fractional time spent by an unretarded solute in each column which, in turn, is determined by the relative column lengths and flow velocities through each column. The second parameter is the relative mass distribution coefficient of a particular solute in each column; a variable that can be adjusted by changing the relative temperatures of the columns. The expression for the effective separation factor relates the measured separation factor for the series combination to the separation factors on the individual columns, the fractional time spent by an unretarded peak in each column, as well as the relative values of the mass distribution coefficients of a particular solute on the different columns.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 69
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 3 (1980), S. 133-142 
    ISSN: 0935-6304
    Keywords: HPLC, UV and EC ; Detector response ratios ; Impurities in Phenol ; Identification using HPLC ; Hydroquinone ; Catechol ; Inactivation of RNA ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Several impurities which were suspected to be present in commercial reagent-grade phenol were separated using high performance liquid chromatography following sample concentration by steam distillation. A reverse-phase, microparticulate column and 5 solvent systems containing 5% to 25% methanol in 0.05 M phosphoric acid were used. A variable wavelength ultraviolet detector and an electrochemical detector were connected in series, in that order, to the column. Capacity factors (ḱ) for pyrogallol, hydroquinone, resorcinol, catechol, orcinol and phenol were determined in the 5 solvent systems and compared to ḱ-values of impurities present in the residue remaining from the steam distillation of phenol. Co-chromatography of standards suspected as contaminants and possessing ḱ-values similar to those of impurities were carried out in 3 solvent systems to confirm identical retention characteristics. Detector response ratios of contaminants and suspected standards, using various wavelengths and voltage potential settings, were utilized as major identification parameters. Two of the several contaminants separated were identified as hydroquinone and catechol.
    Additional Material: 17 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 70
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; Preparation of deactivated capillaries for routine analysis ; Easy deactivation and pretreatment steps described in detail ; Comparison of different modes given ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A new surface pretreatment for the preparation of wall-coated open tubular (WCOT) glass capillary columns has been evaluated. This technique involves the application of a non-extractable layer of Superox™-4, a 4,000,000 MW polyethylene glycol, to the glass surface as a pretreatment and deactivation agent. Unlike other polyethylene glycols, Superox-4 is stable at high temperatures (〉 300°C) in the absence of oxygen, coats smoothly onto a bare glass surface and resists droplet formation. WCOT columns (SE-54, Carbowax 20M, and SP-2250) prepared using this technique are compared to columns prepared using a modified Grob [2,3] BaCO3 procedure. The Superox-4 pretreated columns were equal or superior in quality to the BaCO3 pretreated columns, based on the appearance of an activity standard and the effective theoretical plates (Neff) per meter. Chromatograms showing practical application of the WCOT columns prepared using both methods is given.
    Additional Material: 12 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 71
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 3 (1980), S. 146-146 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Cold trap heating ; Thermal focussing ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 72
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 3 (1980), S. 152-152 
    ISSN: 0935-6304
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 73
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 3 (1980), S. 161-165 
    ISSN: 0935-6304
    Keywords: GC, GC/MS ; Capillary, HMDS-deactivated ; On-column injection ; Nucleoside linkage isomers ; Separation, structural assignment feasibilities ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The analysis of low-volatile polar nucleosides by (GC)2/FID and (GC)2/CI-MS, employing HMDS-deactivated glass capillary columns and on-column injection, is described. The four linkage isomers of a specific nucleoside, formed in the synthetic procedure, are in each case sufficiently well separated in the chromatogram; GC/CI-MS allows for a differentiation of N-7 and N-9 linkage isomers.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 74
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 3 (1980), S. 177-179 
    ISSN: 0935-6304
    Keywords: Separation number TZ (“Trennzahl”) ; Number of base-line separated peaks between homologue pair ; Is system dependent (partition coefficient, mechanical details, dead volumes, temperature) ; Temperature effects studied ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The separation number is affected by a variety of extra-column factors (e.g. the injection process, the nature of the sample, and plumbing defects in the inlet and detector) as well as factors related to column efficiency. The magnitude of the separation number, as affected by the column, varies inversely with column temperature and directly with the partition ratios of the test compounds. The interrelationships of column temperature and partition ratios are explored.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 75
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 3 (1980), S. 199-204 
    ISSN: 0935-6304
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 76
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 3 (1980), S. 302-302 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary ; Fitting silica capillary columns ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 77
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 3 (1980), S. 309-310 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Amino-carboxylic acid ; Silylation ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 78
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 3 (1980), S. 320-320 
    ISSN: 0935-6304
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 79
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 3 (1980) 
    ISSN: 0935-6304
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 80
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 3 (1980), S. 277-285 
    ISSN: 0935-6304
    Keywords: Liquid chromatography, HPLC ; Preparative separation of esters in RP methanol/water systems ; Mono-, di-, tri-, tetraesters ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: This paper demonstrates how simply and rapidly fatty acid esters of mono- and polyhydric alcohols can be separated quantitatively in preparative quantities on Lobar® RP-8 packed columns. After the separation of unknown mixtures, the isolated esters are identified from spectroscopic data (IR/NMR) and, after saponification of the ester components (fatty acids and alcohols), from the retention times of gas and high-pressure liquid chromatographic separations. Thus, in particular, sparingly volatile or nonvolatile partial esters of polyhydric alcohols, as well as the long-chained full esters, can be determined qualitatively and quantitatively.The following fatty acid esters of mono- and polyhydric alcohols have been separated: the i-propylesters of the laurinic and myristinic acids, the i-butyl-, i-octyl- and i-octadecyl-esters of the palmitinic and stearic acids, the mono- and di-fatty acid esters of the 1,3-bis-(2-hydroxyethyl)-5,5-dimethylhydantoins, the mono-, di- and tri-esters of the trimethylalpropane and the full esters of the pentaerythrite.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 81
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 3 (1980), S. 299-300 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, WCOT glass ; Urea herbicides ; s-Triazines herbicides and metabolites ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The authors have shown that capillary columns are perfectly adequate for the separation of s-triazine herbicides and urea herbicides. The method presented remains adequate when the initial molecules are accompanied by some of their metabolites.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 82
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 3 (1980), S. 360-361 
    ISSN: 0935-6304
    Keywords: Standard purging device for soil volatiles ; Sample preparation procedure ; Deuterated internal standard control ; Computerized GC/MS identification ; Analysis within one hour, low ppb sensitivity ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 83
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 3 (1980), S. 376-378 
    ISSN: 0935-6304
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 84
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 3 (1980), S. 400-404 
    ISSN: 0935-6304
    Keywords: Liquid chromatography, HPLC ; Thin-layer chromatography, TLC ; Amniotic fluid ; Fetal lung maturity ; Phospholipids ; Lecithin/Sphingomyelin ratio, L/S ; Shake test ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A method for the HPLC separation of phosphatidylglycerol (PG), phosphatidylinositol (PI), phosphatidylcholine (PC), and sphingomyelin (SPH) was achieved using five in-series columns packed with LiChrosorb, Partisil, and μ-Porasil adsorbents, a solvent mixture of chloroform/methanol/ammonium hydroxide (50 : 36 : 6.7, by volume), and a Pye LCM2 Moving Wire (FID) detector. The same phospholipid mixture was also separated using four μ-Porasil columns with the same eluent and detector. The latter conditions were found to be suitable for the analysis of phospholipids obtained after centrifuging, extraction, and precipitation of surface-active lipid components of patient amniotic fluid collected at amniocentesis section. The lecithin/sphingomyelin (L/S) ratios, determined by the HPLC method, correlated well with those determined by the TLC technique in four normal pregnancies, whereas results of shake tests did not correlate too well with L/S ratios determined by the above two chromatographic methods. Besides the lecithin/sphingomyelin ratio, the present method was able to supply additional information: the concentrations of phosphatidylglycerol and phosphatidylinositol, for prediction of fetal lung maturity, and the palmitic acid content of amniotic fluid phosphatidylcholine.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 85
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 3 (1980), S. 415-416 
    ISSN: 0935-6304
    Keywords: Gas chromatography/mass spectrometry ; Volatile sulfur compounds from waste water ; Adsorption of air samples on tenax GC ; Mechanism of corrosion of concrete ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 86
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 3 (1980), S. 326-332 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Column chromatography ; Run comparison with corrections for variations in injected sample sizes ; Chromatogram reconstruction on a graphics terminal ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The application of a Hewlett-Packard 3354 B Laboratory Automation System has been studied in order to compare a series of gas chromatographic analyses. A computer program has been designed for the chromatogram reconstruction of all valid sample runs from a system subsequence on an HP-2648 A graphics CRT terminal. The detector signals of the runs are compensated for variations in injected sample sizes when a number of conditions are met.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 87
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 3 (1980), S. 345-350 
    ISSN: 0935-6304
    Keywords: Thin-layer chromatography, HPTLC ; Chemical modification of HPTLC-plates ; Organosilanes, polar and non-polar ; Zwitter character of modified silica surface ; Advantageous separation through plate modification ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A method has been developed for the preparation of modified silica plates for high performance thin-layer chromatography (HPTLC). Some typical organosilanes were thus allowed to react in situ with the silica of Merck HPTLC-plates. This method was found to be highly reproducible, simple and cheap. Non-polar plates were prepared and compared with commercial plates from Merck, Whatman and Macherey-Nagel. Modification with cyanodecyltrichlorosilane resulted in plates that showed good coverage, efficiency and low residual silica activity. Silica modified with a multifunctional silane has different properties in different organic solvents. It will appear to be non-polar in a polar solvent and vice versa. New advantageous separation systems are thus made feasible by the presence of cyano groups on the plate.The utility of modified thin-layer plates is demonstrated by the separation of some homologues of p-hydroxybenzoic acid esters and of some polycyclic aromatic hydrocarbons.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 88
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 3 (1980), S. 359-360 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Mass spectrometry ; All-glass interface ; Fused silica ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 89
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 3 (1980), S. 372-375 
    ISSN: 0935-6304
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 90
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 3 (1980) 
    ISSN: 0935-6304
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 91
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 3 (1980), S. 405-410 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Determination of adsorption ; Irreversible adsorption on glass columns made visible ; Fluorescent compound PMBF2 ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: PMBF2, a pyrromethene pigment, can be used in gas chromatography. Because of its fluorescence, adsorption sites on glass columns and connections can be traced in situ. The compound can be employed to check the inertness of glass surfaces after deactivation procedures. Some applications are described.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 92
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 3 (1980), S. 411-412 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; All-glass T-joints and manifolds with small dead volume, production of ; Up to five-channel outlet splitter ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 93
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 3 (1980), S. 421-422 
    ISSN: 0935-6304
    Keywords: Thin-layer chromatography, HPTLC ; Nitroso urea derivatives ; Pyridazine derivatives ; Separation of isomers ; Quantitative determination of isomers ; Fluorescence measurements ; Fluorescence quenching ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 94
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 3 (1980), S. 497-502 
    ISSN: 0935-6304
    Keywords: Capillary gas chromatography ; Diethylbenzenes analysis, C10 aromatics analysis ; Retention indices ; Carbowax-1540 ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A capillary gas chromatographic method for the quantitative analysis of diethylbenzene fractions is described. Estimation of ortho-, meta- and para-isomers and other C9 and C10 aromatic impurities is covered. The conditions developed involve the use of a capillary column of Carbowax-1540 (300 feet × 0.01 inch) under isothermal operation. The retention index data for a number of aromatics are presented at four temperatures (90, 100, 110 and 120°C). The method offers a good choice for any level of concentration both for isomers and impurities commonly encountered within a reasonable analysis time.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 95
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 3 (1980), S. 516-520 
    ISSN: 0935-6304
    Keywords: Glass capillary gas chromatography ; Mass spectrometry ; Alaskan crude oils ; Analysis ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Glass capillary gas chromatography/mass spectrometry is used to profile Alaskan crude oil for purposes of origin verification. Alaskan oil, sampled at Valdez, Alaska, and transshipped to the U.S. East Coast, is compared with 21 samples of foreign crude oil using GC/MS techniques in which original data is reconstructed at selected parent and fragment ions to generate a series of chromatographic profiles. Comparison of selected profiles and compositional parameters derived from peak ratios allows distinction of Alaskan oil from many foreign crudes and may be applied to the examination of crude mixtures.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 96
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 3 (1980), S. 525-526 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; Static coating ; Filling the column by pressure, not by vacuum ; Device for filling by pressure ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 97
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 3 (1980), S. 528-530 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Two-phase derivatization technique ; Yeast ; Splitless injection ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 98
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 3 (1980), S. 545-550 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, fused silica columns ; Selective detectors: TSD, ECD, FPD ; POTW sludge extracts ; Effluent splitter ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Combination of various GC detectors by using a Varian effluent splitter with glass capillary columns has been found to be a rapid procedure for profiling organics extracted from sludges and river sediments. The selectivity and the increased sensitivity of the thermionic nitrogen-phosphorus detector (TSD), the electron capture detector (ECD), and the flame photometric detector (FPD) over the flame ionization detectors (FID) or mass spectrometers allow the detection of compounds present at trace levels without need for extensive sample cleanup. Furthermore, the combination of two selective detectors may supplement the information with regard to the chemical functionalities required for structure elucidation.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 99
    ISSN: 0935-6304
    Keywords: Gas chromatography ; High performance liquid chromatography ; Theoretical basis of column chromatography in multicomponent separations ; Required value of peak resolution and accuracy of obtained, quantitative method ; Plate height of solute with capacity ratio equal to one or approaching to infinity ; Linearity between peak width and retention value ; High efficient GC columns ; HPLC small-bore column ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The point of our published papers since 1957 is reviewed. The relations between the required value of peak resolution, K1 (or R), and peak separation, K3 (eqn 9); K1 and relative accuracy of a peak height quantitative method, Ph (eqn. 10); K1 and relative accuracy of a peak area method, Pa, (eqn. 12) at different concentration ratios, φ, are derived. The final result in Table 2 shows a large influence of φ on the required value of K1.The approximately linear relation between peak width and retention value (eqn. 18) exists not only in GC. but also in HPLC. Plate height values H1 and H∞ for a solute with capacity ratio, k′, equal to unity or approaching infinity, respectively, are used to evaluate the column efficiency (eqn. 20). The measuring methods (eqn. 21,22,23) and parameters effecting on H1 and H∞ are given for GC packed column (eqn. 24), GC open tubular column (eqn. 25) and HPLC (eqn. 26). In the light of this, columns of high efficiency were developed. Some typical chromatograms for high speed analysis and separation of complex mixtures are given.
    Additional Material: 16 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 100
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 3 (1980), S. 585-586 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass or fused silica ; Adsorptive and catalytic activity ; Distinction of effects ; Discussion of active sites ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...