ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Bone  (33)
  • 42.55  (16)
  • Springer  (49)
  • Blackwell Publishing Ltd
  • Institute of Physics
  • 1975-1979  (49)
  • 1950-1954
  • 1945-1949
  • 1977  (49)
Collection
Publisher
  • Springer  (49)
  • Blackwell Publishing Ltd
  • Institute of Physics
Years
  • 1975-1979  (49)
  • 1950-1954
  • 1945-1949
Year
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Calcified tissue international 22 (1977), S. 303-313 
    ISSN: 1432-0827
    Keywords: Osteoclasts ; Sedimentation ; Isolation ; Cells ; Bone
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine , Physics
    Notes: Abstract A method is presented for separating osteoclasts from the heterogeneous population of bone and marrow cells. Cell suspensions were prepared from femora of young rabbits by mechanical dispersion. The starting cell suspension typically contained only 1.0%±0.5 osteoclasts. Following an initial 45 min of unit gravity sedimentation in a lucite chamber osteoclasts were primarily distributed in fractions 2–5. A second 45-min sedimentation of these pooled fractions yielded cell suspensions containing greater than 30% osteoclasts (as much as a 50-fold increase over starting percentages). Linear scan analysis, however, revealed that osteoclasts accounted for 73.14%±0.58 of the cell colume. Subsequent in vitro experiments demonstrated linear incorporation of3H-leucine into TCA precipitable protein for cells comprising the osteoclast fraction. Concomitant radiautographs revealed radioactive label in isolated osteoclasts.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1432-0827
    Keywords: Bone ; Diphosphonates ; Bone resorption ; Bone formation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine , Physics
    Notes: Summary Male rats weighing 100 g were assigned to groups and injected daily for 10 days with vehicle (control), 0.4, 2.0, 4.0, 10.0, or 20.0 mg/kg/day of ethane-1-hydroxy-1,1-diphosphonate (EHDP) or dichloromethylene diphosphonate (Cl2MDP). The proximal tibial metaphysis and epiphysis were assayed for changes in percentage of hard tissue and bone formation parameters. From the data, information about hard tissue resorption was deduced. All doses of Cl2MDP and doses of 2.0 mg EHDP/kg/day and greater caused significant increases in percentage of hard tissues with Cl2MDP being more effective than similar doses of EHDP in decreasing bone resorption. Osteoclast population parameters were increased with all doses of both Cl2MDP and EHDP with Cl2MDP having a greater effect than similar doses of EHDP. Decreases in the proliferation of the osteoprogenitor pool parallel the decreases in osteoblasts and bone formation parameters. These decreases in osteoprogenitor pool proliferation do not account for the increases with diphosphonates in osteoclast population parameters.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Calcified tissue international 23 (1977), S. 283-289 
    ISSN: 1432-0827
    Keywords: Bone ; Resorption ; Osteoclast ; Quantitation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine , Physics
    Notes: Summary The stimulation of bone resorption, assessed by the release of45Ca from prelabeled bones, was associated with an increase in number of osteoclasts per bone section in parathyroid hormone (PTH)-treated bones, but not in lipopolysaccharide (LPS)-treated bones. By contrast the number of nuclei per osteoclast increased following LPS treatment, but was not affected by PTH. LPS-treated bones had more multinucleated cells, some having as many as 27 nuclei per osteoclast. More osteoclasts were adjacent to the bone collar in bones treated with LPS or PTH than in control bones. In LPS-treated bones this area also contained the largest osteoclasts, as determined by the greatest number of nuclei per osteoclast. The results suggest that LPS and PTH stimulate osteoclastic resorption by different mechanisms.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Springer
    Calcified tissue international 23 (1977), S. 303-305 
    ISSN: 1432-0827
    Keywords: Albumin ; Bone ; Hydroxyapatite ; Plasma protein
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine , Physics
    Notes: Summary The extractability of125I-labelled plasma albumin from bone pieces and from powdered bone has been compared after both in vivo and in vitro incorporation. The results show that albumin is more readily extracted from bone pieces than from bone powder which implies that tissue disruption exposes additional protein adsorption sites. It is suggested that incorporation of plasma albumin into calcified matrix during bone formation occurs mainly as a result of its strong interaction with bone mineral.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Springer
    Calcified tissue international 23 (1977), S. 161-170 
    ISSN: 1432-0827
    Keywords: Bone ; Growth ; Rat ; Remodeling ; Tetracyclines
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine , Physics
    Notes: Summary Cortical bone remodeling along the femur diaphysis was determined in normal female rats (Sprague-Dawley) with the tetracycline technique. Three segments on the cortical bone circumference (the anterolateral, the medial, and the posterior) were found to be most suitable for the study of the remodeling process. Oxytetracycline was administered at age 60 and 75 days, and groups of animals were killed at age 75, 85, 95, and 105 days. The accumulated endosteal growth during age 60 to 75 days in the anterolateral segment was found to increase uniformly in the distal direction along the femur diaphysis. A method is described where this accumulated endosteal growth is used. This method eliminates the use of calipers to determine the section level and makes it possible to study comparable sections even after varying periods of time. The proximal part of the diaphysis showed periosteal apposition in all three segments. The periosteal apposition turned into resorption in the distal part of the diaphysis in the anterolateral and medial segments, whereas the periosteal appsition increased in the posterior segment. The endosteal growth increased in the distal direction in the anterolateral and medial segments. Irregular OTC bands made measurements of endosteal remodeling in the posterior segment impossible. The cortical width decreased in the distal direction along the femoral shaft. Comparison between the different age groups is described and also the relation between the accumulated endosteal growth and the diameter of the medullary cavity.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Springer
    Calcified tissue international 23 (1977), S. 1-5 
    ISSN: 1432-0827
    Keywords: Water ; Bone ; Homeostasis ; Structure
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine , Physics
    Notes: Summary A short review is given of the water in bone. Various analyses of bone water content are discussed, and its possible location is considered in relation to the behaviour of water in isolated components of bone. Some of the difficulties encountered in examining such microscopic phenomena as water structure in a heterogeneous system such as bone are also discussed.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Springer
    Calcified tissue international 24 (1977), S. 41-46 
    ISSN: 1432-0827
    Keywords: Lead salt ; Bone ; Mobilization ; Hypercalcemia ; Hyperphosphatemia
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine , Physics
    Notes: Summary The present study is an investigation of the mechanism of hypercalcemia and hyperphosphatemia induced by the intravenous injection of lead acetate (Pb-Ac). A total of 118 male rats were injected with 30 mg/kg of Pb-Ac, or with 16.5 mg/kg of sodium acetate as the control. The levels of serum calcium, phosphorus and lead were then determined at various time periods after the injections. Serum calcium and phosphorus levels increased with time after Pb-Ac injection and the maximum values of calcium (17 mg%) were found after 1 h and of phosphorus (13.5 mg%) after 30 min. Both calcium and phosphorus levels reverted to the normal range after 12 h. The maximum net rates of increase of calcium and phosphorus were found immediately after Pb-Ac injection. At that time, deposition of lead at the calcifying sites of bone and incisor dentin was demonstrated by a histochemical examination. In other experiments the changes in the calcium and phosphorus contents in the medium after shaking bone powder in serum with Pb-Ac in an in vitro system were studied. It was confirmed that the calcium and phosphorus were displaced from the bone mineral, the extent of the displacement being correlated with the concentration of the Pb-Ac added to the medium, and that these displacements were very rapid reactions. These results suggest that hypercalcemia and hyperphosphatemia following Pb-Ac injection results from a direct action of lead on the bone mineral.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Springer
    Calcified tissue international 24 (1977), S. 209-214 
    ISSN: 1432-0827
    Keywords: Parathyroid hormone ; Plasma calcium ; Radiocalcium ; Bone
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine , Physics
    Notes: Summary The net rate of loss of45Ca from plasma was monitored in normal, thyroparathyroidectomized (TPTX), and nephrectomized rats. Also studied was the effect of a 24 h intravenous infusion of PTH in TPTX rats. The45Ca was injected after an overnight fast and 1 to 4 h prior to the time the first blood sample was obtained. In normal rats, the net rate of loss of45Ca from plasma was slower than in TPTX rats for at least 12 h after radionuclide injection. Nephrectomy did not affect this difference between control and TPTX rats until 8 h after45Ca injection or about 18 h after nephrectomy. At this time a reversal occurred and the net rate of plasma45Ca loss in nephrectomized rats with parathyroids became faster than in TPTX nephrectomized rats. When PTH was infused at a constant rate (3 mU/g body weight/h) plasma calcium concentrations rose gradually for approximately 12 h after which a constant plasma calcium level was maintained with continued PTH infusion. During the period when plasma calcium concentrations were rising, the net rate of loss of45Ca from plasma was slower than in TPTX controls infused only with saline. However, when plasma levels stabilized, plasma45Ca disappearance rates changed such that the rate loss of45Ca from plasma became faster in PTH-infused than in TPTX controls. It is concluded that PTH increases calcium efflux from the same compartment in bone which receives calcium from plasma, thereby returning some recently deposited45Ca to plasma. In the non-equilibrated state, this returns additional45Ca to plasma causing anet decrease in the rate of loss of45Ca from plasma. However, in the equilibrated condition, when both calcium efflux from bone and influx into bone are in balance but at higher flux rates, PTH stimulates the diffusion of45Ca into other bone compartments.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    ISSN: 1432-0630
    Keywords: 42.55
    Source: Springer Online Journal Archives 1860-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: Abstract Lasing in atomic lines of noble gases and fluorine, prior to excimer radiation, was observed in an electric discharge ArF/XeF excimer laser. Some Ar/Xe lines end at metastable levels, which are very important for the formation of ArF/XeF excimer molecules. Five new lasing lines of atomic fluorine have been obtained. Consideration is given to the use of lasing in atomic and molecular lines, that occurs in one burst, in investigations of the excitation kinetics of excimer states under the conditions of a high-pressure electric discharge.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Springer
    Applied physics 14 (1977), S. 277-282 
    ISSN: 1432-0630
    Keywords: 42.55 ; 52
    Source: Springer Online Journal Archives 1860-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: Abstract The paper deals with the properties andI-V characteristics of discharges in narrow capillaries used, for example, for He−Ne waveguide lasers. It has been observed that discharges in He−Ne waveguide lasers are unstable because of the strongly falling characteristic. A theory is presented which assumes that at low currents wall charges restrict the positive column to a narrow plasma channel and are the main reason for the observed falling characteristic. A numerical evaluation for helium gives results which agree well with experimental data.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 11
    Electronic Resource
    Electronic Resource
    Springer
    Applied physics 13 (1977), S. 97-99 
    ISSN: 1432-0630
    Keywords: 42.55 ; 82.50
    Source: Springer Online Journal Archives 1860-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: Abstract First cw laser oscillation with thresholds below 1 mW was observed for various B1Пu → X1 ∑ g + transitions of diatomic molecular sodium excited by different argon laser lines in the range of 454–488 nm. For pump powers of 0.5 W output powers up to 3 mW and single-pass gain up to 0.1 cm−1 were obtained. Some properties of the heat pipe laser system are discussed.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 12
    Electronic Resource
    Electronic Resource
    Springer
    Applied physics 13 (1977), S. 383-385 
    ISSN: 1432-0630
    Keywords: 42.55 ; 42.80
    Source: Springer Online Journal Archives 1860-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: Abstract An optically pumped FIR laser was operated with a copper mesh Fabr-Perot output coupler. With this device a Gaussian output beam was obtained andthe degree of coupling could be varied continuously, thus allowing optimum coupling. From the measured properties of the wire mesches grains of two FIR laser lines are calculated and the saturation intensities estimated.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 13
    Electronic Resource
    Electronic Resource
    Springer
    Applied physics 14 (1977), S. 25-28 
    ISSN: 1432-0630
    Keywords: 42.55 ; 42.80
    Source: Springer Online Journal Archives 1860-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: Abstract A new device for magnetically displacing the output mirror of a laser resonator and synchronously tilting an etalon in order to obtain single-mode tuning of a dye laser over a tuning range of at least 10 GHz is described. Comparatively large displacements with good linearity of a coil mounted on a membrane and placed inside the strong magnetic field of a ring magnet are obtained for currents in the order of several hundred milliamperes. Together with etalon flats of appropriate thickness and reflection mounted in the resonator of the laser a versatile instrument for application in intra and extra cavity spectroscopy has been developed.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 14
    Electronic Resource
    Electronic Resource
    Springer
    Applied physics 14 (1977), S. 393-398 
    ISSN: 1432-0630
    Keywords: 34 ; 42.55
    Source: Springer Online Journal Archives 1860-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: Abstract A flowing afterglow method has been used to study a number of reactions of importance in KrF lasers using NF3 as the fluorine donor. Total rate constants are reported for Kr*(3 P 2)+NF3 and Kr++NF3. The thermal energy attachment coefficient has been measured for NF3 and the cross section for the electron excitation process Kr*(3 P 2) +e→Kr*(3 P 1)+e has been estimated. The relevance of these results to discharge pumped KrF lasers is discussed.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 15
    Electronic Resource
    Electronic Resource
    Springer
    Applied physics 14 (1977), S. 193-197 
    ISSN: 1432-0630
    Keywords: 42.55 ; 52
    Source: Springer Online Journal Archives 1860-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: Abstract Planar and cylindrical discharges for argon lasers are compared by plasmatheoretical calculations. The maximum laser output power available in the two arrangements is computed in dependence of various parameters neglecting saturation mechanisms. A transverse discharge arrangement confining the positive column by two parallel walls is described and experimental laser threshold values for the current and pressure are reported.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 16
    Electronic Resource
    Electronic Resource
    Springer
    Applied physics 14 (1977), S. 255-268 
    ISSN: 1432-0630
    Keywords: 42.80 ; 42.55 ; 85.60
    Source: Springer Online Journal Archives 1860-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: Abstract GaAs double heterostructure semiconductor injection lasers which now exhibit more than 25000 h cw room temperature lifetime are of great interest for future use as directly modulated transmitters for high bit-rate fiber optical communications. The effects limiting this application are modulation distortions, spectral width and additional spectral broadening in the case of modulation and spontaneous fluctuations of the output power. The dynamic and spectral behavior of injection lasers, the methods of high bit-rate modulation and the improvement of the high bit-rate modulation capability by coupling two lasers are discussed.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 17
    Electronic Resource
    Electronic Resource
    Springer
    Applied physics 13 (1977), S. 109-110 
    ISSN: 1432-0630
    Keywords: 42.55
    Source: Springer Online Journal Archives 1860-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: Abstract A simple technique is described that allows the generation of a short pulses (1 ns) from dye lasers pumped by a much longer (7 ns) N2-laser pulse. Dye-laser pulses, either with a narrow bandwidth or a short duration, can thus be obtained with the same N2-laser pump.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 18
    Electronic Resource
    Electronic Resource
    Springer
    Applied physics 14 (1977), S. 121-122 
    ISSN: 1432-0630
    Keywords: 42.55
    Source: Springer Online Journal Archives 1860-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: Abstract Frequency-tunable generation by means of F 2 + and F 2 − colour centers in a LiF crystal is reported. Colour centers were created by illuminating LiF crystals with electrons of 3 meV energy at the electron current density of 1 μA/cm2. The pumping source was a ruby laser with a peak power of 20 MW, a pulse duration of 20 ns, and a repetition rate of 1 Hz. The frequency tuning is obtained in the range of 0.88–1.25 μm. Discussed are the ways of pumping of colour centers and the possibility of lasing in the spectral region of 0.85 to 2 μm in the type of colour centers under investigation.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 19
    Electronic Resource
    Electronic Resource
    Springer
    Applied physics 13 (1977), S. 107-108 
    ISSN: 1432-0630
    Keywords: 42.55
    Source: Springer Online Journal Archives 1860-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: Abstract Intense laser oscillation has been observed from ArF molecules at 1933 Å. Excitation of the gas mixture NF3:Ar:He=1:55:630 at total pressures above 2.1 atm was produced by a transverse electric discharge. The range of fine tuning was from 1927 Å to 1936 Å. An output energy of 0.8 mJ was measured from a laser pulse 15 ns in duration.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 20
    Electronic Resource
    Electronic Resource
    Springer
    Applied physics 13 (1977), S. 1-3 
    ISSN: 1432-0630
    Keywords: 42.55
    Source: Springer Online Journal Archives 1860-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: Abstract Disappearance of NF3 and appearance of NF2 and N2F2 in an excimer laser is followed quantitatively with a mass spectrometer. A model for the kinetics is presented.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 21
    Electronic Resource
    Electronic Resource
    Springer
    Applied physics 13 (1977), S. 55-58 
    ISSN: 1432-0630
    Keywords: 42.55 ; 78.60
    Source: Springer Online Journal Archives 1860-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: Abstract NdxLa1−xP5O14 (0.25≦x≦1) single crystals, placed within a confocal optical resonator, were pumped with ruby laser fundamental and second-harmonic nanosecond pulses. In both cases laser oscillations at 1.05 μm exceeding in duration many times the pumping pulse were obtained.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 22
    Electronic Resource
    Electronic Resource
    Springer
    Applied physics 14 (1977), S. 343-350 
    ISSN: 1432-0630
    Keywords: 33 ; 42.55
    Source: Springer Online Journal Archives 1860-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: Abstract By means of nonlinear absorption spectroscopy data necessary for the interpretation of molecular spectra can be obtained in such spectral regions, where conventional spectroscopic methods yield only a quasi-continuous absorption curve. Using a Zeeman-tuned He−Ne laser at the wavelength of 3.39μm we have measured significant differences in the intensity and temperature behaviour for several ethane absorption lines, the analysis of which made possible a preliminary qualitative assignment of these lines.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 23
    Electronic Resource
    Electronic Resource
    Springer
    Applied physics 14 (1977), S. 377-380 
    ISSN: 1432-0630
    Keywords: 42.55 ; 42.65
    Source: Springer Online Journal Archives 1860-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: Abstract Due to spatial hole burning, standing-wave dye lasers require a large amount of selectivity inside the cavity for single-mode operation. The output power of these lasers is limited by losses caused by the frequency selecting elements. In a travelling-wave laser, on the other hand, spatial hole burning does not exist, thereby eliminating the need for high selectivity. A travelling-wave cw dye laser was realized by unidirectional operation of a ring laser, yielding single mode output powers of 1.2 W at 595 nm and of 55 mW in the UV-region with intracavity frequency doubling.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 24
    Electronic Resource
    Electronic Resource
    Springer
    Applied physics 14 (1977), S. 199-203 
    ISSN: 1432-0630
    Keywords: 42.55 ; 82.50
    Source: Springer Online Journal Archives 1860-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: Abstract Loss of gain in a dye medium as a result of decomposition by pump photons is considered in terms of disappearance of dye molecules and the appearance of a new, single chemical product having absorption in the fluorescence band. The cases of small signal gain and saturated gain are applied to a single pass through a transversely excited amplifier. Loss of output, defined as “quantum yield of laser deterioration”,Q L , is related to the true quantum yield of molecular destruction of the dye,Q M , and other known parameters. For the experimentally common, saturated gain condition, the smallestQ L can be isQ M , which requires a photochemically bleachable dye with high gain, preferably at high concentration, in a long cavity, operating at high injection and pumping fluxes. Reversing these conditions, the highest valueQ L can be, compared withQ M , is unrestricted.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 25
    Electronic Resource
    Electronic Resource
    Springer
    Calcified tissue international 23 (1977), S. 185-188 
    ISSN: 1432-0827
    Keywords: Matrix vesicles ; Bone ; Ultracrytomy
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine , Physics
    Notes: Summary Matrix vesicles were observed in femurs of 8-day-old chick embryos prepared by ultracryotomy. Some of the sections were subjected to ultramicroincineration. The unfixed tissues never came into contact with solutions, and thereby artifacts due to dissolution, redistribution, or rearrangement of the mineral constituents were avoided. In the osteoid, electron dense objects with the size and appearance of matrix vesicles were seen, although limiting membranes were not visible. After ultramicroincineration the vesicles were observed to contain small crystals and a less dense amorphous mineral material which may be the precursor of bone mineral. In addition, a ring of ash enclosed the crystalline and amorphous mineral and appeared to occupy the position of the vesicle membrane as seen in conventionally prepared material.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 26
    Electronic Resource
    Electronic Resource
    Springer
    Calcified tissue international 24 (1977), S. 93-98 
    ISSN: 1432-0827
    Keywords: Magnesium ; Bone ; Mineral ; Chick embryo ; Organ culture
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine , Physics
    Notes: Summary Using bone organ culture techniques, three concentrations of magnesium were evaluated for their effects on the mineral mass of embryonic chick tibiae incubated for 3 days with or without a metabolic inhibitor (1 mM iodoacetic acid) added to the media. Varying the medium Mg level from 0.3 to 3.0 mM had little effect on the net increase in mineral in live bones (without the inhibitor), but in dead tibiae (with the inhibitor) there was a marked net decrease in mineral deposition with increasing Mg concentration. Bone Mg mass varied directly with the level of Mg in the medium regardless of whether or not the tibiae were inhibited. Responsiveness to parathyroid hormone (PTH) with regard to mineral loss and increased lactate production was not affected by Mg even in tibiae incubated in Mg-free media. However, PTH-treated bones cultured in Mg-free media had a significantly elevated Mg mass, suggesting that the hormone may have a Mg-conserving effect on bone during severe Mg deficiency. The findings of this study support the hypothesis that bone cells regulate the level of Mg to which newly forming mineral is exposed and that PTH-responsiveness in embryonic chick tibiae is not dependent on the ambient Mg concentration.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 27
    Electronic Resource
    Electronic Resource
    Springer
    Calcified tissue international 22 (1977), S. 9-17 
    ISSN: 1432-0827
    Keywords: Bone ; Fluoride ; Calcium ; Phosphorus ; Mechanical Strength
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine , Physics
    Notes: Abstract Four groups of weanling rats were fed for 2 weeks on a diet sufficient or insufficient in calcium and/or phosphorus. Each group was divided into four subgroups which were offered distilled water supplemented with 0, 50, 75, or 150 ppm fluoride. High levels of fluoride in drinking water inhibited weight gain. This inhibition was less in rats deficient in phosphorus than when normal-phosphorus diets were offered. At a low level, fluoride was without any effect on bone ash, thickness of femoral cortical bone, and mechanical strength, as measured by maximal load, ultimate stress to breaking, and limit of elasticity. Modulus of elasticity was decreased. At higher levels fluoride tended to decrease most of these parameters, except in rats deprived of both calcium and phosphorus. The effect of fluoride was modified by lack of dietary calcium and/or phosphorus and appeared to be weaker in rats deficient in these nutrients. Lack of dietary calcium and/or phosphorus decreased bone strength more than did fluoride content of water and of bone mineral. Concentration of bone ash and thickness of femoral cortical bone were closely correlated with parameters of mechanical strength.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 28
    ISSN: 1432-0827
    Keywords: Parathyroid hormone ; Plasma calcium ; Radiocalcium ; Bone
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine , Physics
    Notes: Abstract Acute changes in plasma calcium and45Ca were studied in young adult male thyroparathyroidectomized (TPTX) rats injected with moderate doses of parathyroid hormone (PTH). For plasma calcium changes, comparison was made between rats fasted or fed prior to PTH injection. For plasma45Ca changes, the effect of the time of administration of the radionuclide was also studied; this included rats injected with PTH 1 h after radionuclide (“1 h45Ca”), 18 h later (“18 h45Ca”) and more than 6 days later (“6 day45Ca”). The results can be summarized as follows: (1) Plasma calcium changes were greater when PTH was injected into “fed” rather than into “fasted” rats. (2) PTH always produced a relative increase (compared to controls tested concurrently) in plasma45Ca concentrations. This increase was the same in the “1 h45Ca” and the “18 h45Ca” groups. (3) Plasma45Ca rose at least temporarily following PTH injection in the “18 h45Ca” group. (4) The45Ca rise following PTH was always greater in “fed” than in “fasted” groups. (5) Plasma45Ca specific activities (S.A.) tended to rise in the “6 day45Ca” group and to fall in the “18 h45Ca” group, following PTH injection. However, the45Ca S.A. was always higher in fed than fasted groups. (6) In a few experiments in which32P was injected with45Ca, specific activity changes in plasma45Ca following PTH injection werenot accompanied by similar changes in32P specific activity. These results could not be adequately explained by PTH effects on bone resorption, but the data supported the postulate that PTH controls plasma calcium concentrations by increasing transport of calcium through the osteocyte-lining cell (osteoblast) bone cell complex from the bone fluid compartment to the ECF.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 29
    Electronic Resource
    Electronic Resource
    Springer
    Calcified tissue international 22 (1977), S. 275-284 
    ISSN: 1432-0827
    Keywords: Bone ; Calcium ; Collagen ; Dentine ; Phosphoprotein
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine , Physics
    Notes: Abstract Calcium-binding and biochemical studies have been applied to characterize the state of the carboxylate and protein-bound phosphate groups in the EDTA-demineralized matrices of rat bone and dentine. The organic phosphate and carboxylate content of demineralized bone is virtually identical to that of purified steer skin collagen whereas demineralized dentine has a significantly higher phosphate and carboxylate content, presumably due to the presence of an acidic non-collagenous phosphoprotein. Two classes of calcium-binding sites can be detected in demineralized bone, demineralized dentine, and purified, reconstituted collagen. The number of strong calcium-binding sites correlates with the number of protein-bound phosphate groups. Depending on the preparative procedure, seven to nine such sites (per collagen molecule) are present in dentine, and one to two in the purified reconstituted collagen and in bone. The binding constant for the dentinal sites (1.1×104 M−1), however, is 20 times greater than that for bone or reconstituted collagen fibrils from skin. We tentatively conclude that the strong calcium-binding site in bone and reconstituted collagen is of the form protein-PO 4 − Ca++ whereas in dentine it is of the form the weak binding sites in bone and dentine are of the form protein-COO-Ca++; and that approximately 160 of the 217 carboxylate groups of the collagen molecules of dentine or bone are present as electrostatic linkages of the form protein-COO−+H3N-protein.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 30
    Electronic Resource
    Electronic Resource
    Springer
    Calcified tissue international 22 (1977), S. 315-327 
    ISSN: 1432-0827
    Keywords: Bone ; Bioelectricity ; Strain ; Locomotion ; Osteoporosis
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine , Physics
    Notes: Abstract Using wet dead specimens it was possible to show that the size and form of strain-related electrical potentials on the surface of sheep radii were related both to the amount of strain, and the strain rate, over the range of these recorded during locomotion. Using the same electrode and amplifier system in vivo changes in surface strain and surface charge were recorded from the radius of three sheep during locomotion. During slow locomotion electrical changes were negligible. At medium speed they were most variable, and profoundly influenced by small alterations in the timing and pattern of strain change. When locomotion was fast the electrical waveform reflected fairly faithfully the changes in strain on the bone surface.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 31
    Electronic Resource
    Electronic Resource
    Springer
    Calcified tissue international 22 (1977), S. 329-331 
    ISSN: 1432-0827
    Keywords: Bone ; Fracture ; Mineral
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine , Physics
    Notes: Abstract The bone mineral content was measured by gamma absorptiometry in patients who had sustained fractures of the upper limb. Measurements were taken on the shafts of the forearm and in the trabecular bone immediately proximal to the wrist. Fractures of the surgical neck of the humerus and fractures of the shaft of the humerus did not significantly influence the bone mineral content of the ipsilateral forearm. Fracture of the radius and the ulna, however, caused a 15% loss of the bone mineral content in the trabecular bone proximal to the wrist, whereas the mineral content on the shafts of the fractured forearms increased or decreased depending on the fracture site. The findings suggest that measurements of bone mineral content of the forearm are not necessarily invalidated if there has been a fracture of the same limb. Only if the forearm itself is fractured should measurements on this site be avoided.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 32
    Electronic Resource
    Electronic Resource
    Springer
    Calcified tissue international 23 (1977), S. 215-223 
    ISSN: 1432-0827
    Keywords: Amorphous mineral ; Bone ; Electron microscopy ; Ultracryotomy ; Ultramicro-incineration
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine , Physics
    Notes: Summary The fine structure of the extracellular phase of avian medullary bone and embryonic chick femur was examined in thin sections prepared by ultracryotomy and ultramicroincineration. Since contact with solutions was completely avoided, little or no loss or dislocation of mineral constituents could occur. Amorphous bone mineral (ABM) was present in two forms: as 15–30 nm spheres and as a structure-free haze. Removal of all organic material by low temperature ashing left the ABM intact. Crystals were usually associated with the ABM. In newly ossifying regions clusters or nodules of randomly oriented crystals and ABM appeared to coalesce when they reached approximately 1 μm in diameter. In highly calcified regions crystals appeared to be oriented along collagen fibers. ABM did not appear to be associated with collagen. Unmineralized collagen was visible in osteoid after staining with dry OsO4 vapor and it appeared to be diverted around nodules. Structures which resembled matrix vesicles were present. Selected area electron diffraction patterns indicated the presence of hydroxyapatite.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 33
    ISSN: 1432-0827
    Keywords: Bone ; Calcium ; Strontium ; Apposition ; Tracer analysis
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine , Physics
    Notes: Abstract 1. Evidence has accumulated that the rate of acceretion (A) of calcium to bone is the sum of two fluxes; apposition involving the laying down of new bone and augmentation which is the result of slow exchange of non-surface bone calcium with plasma calcium pools as the result of solid state diffusion. 2. A method has been devised for separating A into its two components. It requires the use of45Ca or, for clinical studies,85Sr as a calcium tracer. Studies which are initiated with a combined accretion rate-calcium balance study, are concluded with an estimate of the exponent of the power function which has been found to describe the whole body retention of tracer from the second month onward. 3. The impulse response function of the skeleton for the tracer is then calculated, making the assumption that in any uniform volume of bone, osteoclastic resorption is a first order process. Making in addition certain simplifying assumptions, which are shown to have a modest influence on the final results, a mean rate of bone resorption can be calculated using a development of the well known Stewart-Hamilton formula. The apposition rate is calculated as the sum of the resorption rate and the calcium balance. Augmentation and diminution, defined as equal and opposite exchange processes, are given by the difference between A and the apposition rate. 4. The results of our first thirteen studies in normal subjects and patients with metabolic bone disease are presented, together with analyses of some data from the literature. It is concluded that the development of an atraumatic method for measuring rates of bone formation and resorption in the whole body would be an important advance in the study of metabolic bone disease, and this work is presented so that critical comparisons may be initiated between this tracer method and independent histological methods for measuring these parameters.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 34
    ISSN: 1432-0827
    Keywords: Electron spin resonance ; Crystallinity ; Bone ; Osteons
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine , Physics
    Notes: Summary Several groups containing 10–15 isolated osteons differing in their degree of maturity were analysed. Samples were isolated from undecalcified human and bovine bone sections. The crystallinity coefficient, defined as the ratio of the number of radiation-induced paramagnetic defects in the crystalline lattice of hydroxyapatite to the total ash content, was calculated. The results were compared with measurements performed on fragments of total cortical bone, primary periosteal bone, and inner circumferential lamellar bone. The results show a higher crystallinity of fully calcified osteons as compared with that found at the initial stage of calcification. No differences in the ash content were observed between human osteons, from different stages of calcification evaluated morphologically and by X-ray absorption. These differences were evident when bovine osteons differing in their stage of calcification were compared. Human fully calcified osteons contain 60% ash and their crystallinity coefficient is 52.1. Human osteons at the initial stage of calcification contain 57% ash and their crystallinity coefficient is 40.6. The same parameters for fully calcified bovine osteons and for bovine osteons at the initial stage of calcification are 59% ash, 62.6 crystallinity coefficient and 46% ash, 43.0 crystallinity coefficient, respectively.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 35
    Electronic Resource
    Electronic Resource
    Springer
    Calcified tissue international 24 (1977), S. 65-72 
    ISSN: 1432-0827
    Keywords: Bone ; Strength ; Tension ; Microstructure ; Osteon
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine , Physics
    Notes: Summary Standardized human and beef femoral compact bone specimens were tested in tensile impact and the dynamic mechanical properties were determined. The microstructure of 45 beef and 47 human bone specimens were examined histologically to determine if there is a structural basis to account for strength differences in the bone samples. Strong negative correlations were obtained between the maximum stress and the percentage area of secondary osteons in each specimen. For human bone samples, the energy absorption capacity and the modulus of elasticity were also found to have strong negative correlations with the percentage area of secondary osteons present in each specimen. Linear regression equations were obtained describing the impact strength properties in terms of the percentage areas of secondary osteons and cavities in the samples. Fracture surfaces of the tested bone specimens were examined in a scanning electron microscope. Most surfaces exhibited a fairly rough texture indicating a quasi-cleavage type of failure. Fractographic analysis of bone fracture surface was helpful in understanding the micromechanics of bone fracture.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 36
    ISSN: 1432-0827
    Keywords: Bone ; Density ; Composition ; Renal osteodystrophy ; Dogs
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine , Physics
    Notes: Summary Bone density and composition were studied in trabecular and cortical bone from control 2 and 4 year old beagles and those which had various degrees of renal failure as a result of perinatal irradiation. Changes in the two types of bone were qualitatively similar but consistently greater in trabecular bone. In a group identified as markedly uremic, the decrease (P〈0.025) from control levels in specific gravity was about 4 times greater in trabecular than in cortical samples. The decrease (P〈0.025) in grams of ash/ml was 9% in trabecular bone and 2% in cortical bone. These changes were associated with an increase (P〈0.001) in water content and, on a percent by volume basis, approximately equal decreases in ash (P〈0.025) and combustible matter (P〈0.025). In a mildly uremic group there were similar trends in mean values but the only significant difference was an increase (P〈0.001) in trabecular bone water.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 37
    Electronic Resource
    Electronic Resource
    Springer
    Calcified tissue international 24 (1977), S. 201-208 
    ISSN: 1432-0827
    Keywords: Calcitonin ; Plasma calcium ; Radiocalcium ; Bone
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine , Physics
    Notes: Summary The effect of intravenous salmon calcitonin (SCT) infusion on the net rate of loss from plasma of recently injected45Ca has been studied in conscious fasted rats, some of which had been previously thyroparathyroidectomized (TPTX). The45Ca was injected 10 h prior to or 1 or 2 h after the initiation of the infusion. Salmon calcitonin (0.05–0.2 MRC mU/g body weight/h) infusion produced the expected hypocalcemia and hypophosphatemia. The drop in plasma calcium levels produced by the hormone was lowered further by the addition of phosphate to the infusate. Plasma45Ca changes, during SCT infusion, followed a biphasic pattern when the radionuclide injection preceded SCT infusion by 10 h. During the first part of the infusion, the rate of loss of45Ca from plasma was greater in SCT-treated than in control rats. Later, this pattern reversed, and the rate of loss of45Ca from plasma became slower in SCT-treated animals. If45Ca was injected after SCT infusion was initiated only the second phase of the biphasic effect was observed; i.e., disappearance of45Ca from plasma was slower in SCT-infused than in control rats. These data are considered to support the hypothesis that rapid and opposing calcium fluxes exist between bone fluid and plasma, and that calcitonin acts by decreasing the calcium efflux from bone fluid. The calcium moved in this efflux system includes some that has only recently entered bone fluid from plasma. This is the explanation given for the initial decrease in plasma45Ca concentrations following SCT infusion. The reverse effect in the second phase can be explained as the result of a secondary reduction in calcium influx to bone fluid from plasma.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 38
    Electronic Resource
    Electronic Resource
    Springer
    Calcified tissue international 23 (1977), S. 113-114 
    ISSN: 1432-0827
    Keywords: Bone ; Absorption Spectra ; Collagen ; Hydroxyapatite
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine , Physics
    Notes: Summary Absorption spectra of human bone and its two major constituents (collagen and apatite) were obtained in the wavelength region extending from 2000 to 12,000 Å. In the last two cases a, minimum transmission (maximum absorption) was uniformly observed in the ultraviolet region. The two samples after exposure to ultraviolet radiations show a shift in the peak positions. Absorption peaks in the total bone spectra are not reproducible in its two constituents. After exposure to UV radiations the position of maximum absorption is displaced. A possible interpretation of the observed results is presented.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 39
    ISSN: 1432-0827
    Keywords: Parathyroidectomy ; Diphosphonates ; Bone ; Collagen ; Hydroxyproline
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine , Physics
    Notes: Summary Disodium ethane-1-hydroxy-1,1-diphosphonate (EHDP) may impair mineralization and reduce turnover of bone. However, its administration has been shown to lead to an accumulation of osteoid in both man and the rat. Using rats, the effects of surgical parathyroidectomy and administration of EHDP (30 mg EHDP/kg body weight by subcutaneous injection daily for 5 days) upon bone composition, uptake of3H-proline into hydroxyproline in bone and the subsequent urinary excretion of labelled and unlabelled hydroxyproline have been compared. Both parathyroidectomized (PTX) rats and EHDP-treated animals accumulated more hydroxyproline in bone and excreted less total urinary hydroxyproline than sham-PTX control animals, the changes induced by EHDP being of greater magnitude than those induced by surgical parathyroidectomy. Skeletal buildup of hydroxyproline was associated with decreased catabolism of mature collagen rather than enhanced synthesis of hydroxyproline in bone. EHDP administration, although decreasing urinary excretion of newly synthesised hydroxyproline, did not alter the skeletal synthesis of hydroxyproline as measured by uptake of3H-proline. In all parameters measured, responses to EHDP were similar in PTX and sham-PTX rats. It is concluded that depression of parathyroid hormone mediated bone turnover may have contributed to, but did not fully account for, the lowering of bone turnover and changes in bone composition induced by EHDP in sham-PTX rats in the present experiment.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 40
    Electronic Resource
    Electronic Resource
    Springer
    Calcified tissue international 22 (1977), S. 27-33 
    ISSN: 1432-0827
    Keywords: Protein ; Bone ; Blood plasma ; Dentine
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine , Physics
    Notes: Abstract The spectrum of plasma proteins present in human cortical bone and permanent dentine has been determined. One plasma glycoprotein, theαHS-glycoprotein, was found to be present at a high concentration in both bone and dentine and was shown to be concentrated in the mineralized tissues with respect to the other plasma proteins by factors of between 30 and 100. In this respect theαHS-glycoprotein is analogous to the G2B-glycoprotein and α-glycoprotein of bovine and rabbit b one, respectively. The binding ofαHS-glycoprotein and albumin to calcium phosphates generated within serum samples has been studied at different serum: precipitate ratios. In each case all theαHS-glycoprotein was removed from the samples and theαHS-glycoprotein was concentrated with respect to albumin by factors ranging from 370 at the highest serum: precipitate ratio to 25 at the lowest ratio. The plasmaαHS-glycoprotein concentrations of patients with Paget's disease of bone were shown to be substantially lower than the normal range, with significant negative correlation between theαHS-glycoprotein concentration and the plasma alkaline phosphatase activity.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 41
    Electronic Resource
    Electronic Resource
    Springer
    Calcified tissue international 22 (1977), S. 183-189 
    ISSN: 1432-0827
    Keywords: Calcium ; Strontium ; Bone ; Mathematical modelling
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine , Physics
    Notes: Abstract 1. A method has been devised for comparing the impulse response functions of the skeleton for two or more boneseeking tracers, and for estimating the contribution made by measurement errors to the differences between any pair of impulse response functions. 2. Comparisons were made between the calculated impulse response functions for47Ca and85Sr obtained in simultaneous double tracer studies in sixteen subjects. Collectively the differences between the47Ca and85Sr functions could be accounted for entirely by measurement errors. 3. Because the calculation of an impulse response function requires fewera priori assumptions than other forms of mathematical analysis, and automatically corrects for differences induced by recycling of tracer and non-identical rates of excretory plasma clearance of tracer, it is concluded that differences shown in previous in vivo studies between the fluxes of*Ca and*Sr into bone can be fully accounted for by undetermined oversimplifications in the various mathematical models used to analyse the results of those studies.85Sr is therefore an adequate tracer for bone calcium in most in vivo studies.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 42
    Electronic Resource
    Electronic Resource
    Springer
    Calcified tissue international 22 (1977), S. 219-226 
    ISSN: 1432-0827
    Keywords: Hydroxyapatite ; Bone ; X-ray Diffraction
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine , Physics
    Notes: Abstract Evidence relating to the existence of crystalline bone mineral in vivo is considered, and bone apatite crystal structure investigated using an x-ray powder diffraction technique. Specimens of femoral compacta excised post-mortem from male and female subjects ranging from 3 1/2 years to 87 years of age have been studied. Values of the ratio c/a of bone apatite crystal cell axes for females are significantly higher (p〈0.05) than for males. Moreover, significant change of c/a with age is observed for males (p=0.0005) but not for females (p=0.30). Differences in c/a are interpreted as indicating substitution of constituent ions in the bone apatite crystals.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 43
    ISSN: 1432-0827
    Keywords: Diphosphonate ; Bone ; Osteoclasts ; Autoradiography
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine , Physics
    Notes: Abstract Male rats weighing 100 g were injected with vehicle (control group), 0.4 or 4.0 mg/kg/day of ethane-1-hydroxy-1,1-diphosphonate (EHDP). Beginning after 6 days of EHDP treatment all rats received six subcutaneous injections of3H-thymidine at 8 h intervals. The multiple labeling index of autoradiographically defined labeled cells was determined for the osteoprogenitor cells of the primary spongiosa of the proximal tibial metaphysis. The osteoclasts in the proximal tibial metaphysis were assayed for population parameters and incorporation of labeled nuclei at sequential intervals after the administration of3H-thymidine. After 6 days of EHDP pre-treatment the multiple labeling index of the osteoprogenitor cells was reduced with 4.0 mg/kg/day dose of EHDP. At the beginning of the experimental kinetic sampling period, after the 6 days of EHDP pre-treatment, EHDP treatment resulted in significant increases in the numbers of osteoclasts, nuclei per osteoclast profile, and total osteoclast nuclei. During the sampling period, the 4.0 mg/kg/day dose of EHDP caused further increases in the number of total osteoclasts. EHDP treatment caused a marked increase in the rate of incorporation and accumulation of3H-thymidine-labeled nuclei in osteoclasts. Thus, EHDP causes an accelerated rate of osteoclast production from precursor cells in spite of its ability to slow bone resorption. Although the origin of osteoclast nuclei is not clear, the kinetic data from this study suggests that osteoclast nuclei are not arising from osteoprogenitor cells or osteocytes in the EHDP-treated animals.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 44
    Electronic Resource
    Electronic Resource
    Springer
    Calcified tissue international 23 (1977), S. 103-112 
    ISSN: 1432-0827
    Keywords: Albumin ; Polyvinylpyrrolidone ; Tissue fluid ; Bone
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine , Physics
    Notes: Summary The passage of tissue fluid through cortical bone has been investigated using radioactively labelled macromolecules as markers. The results suggest that in the cortex of young rabbit femur the movement of tissue fluid is in the same net direction as blood, mainly from the endosteal to the periosteal surface. Some albumin is incorporated from extravascular tissue fluid into calcified matrix at sites of bone formation. Polyvinylpyrrolidone, average molecular weight 35,000 is able to pass through extravascular tissue fluid in bone but isnot incorporated into calcified matrix. In rabbits made vitamin D deficient, much less albumin is retained in regions of bone formation than is the case with controls. Albumin adsorbs to the surface of calcium phosphate precipitates and it is suggested that this mechanism may be mainly responsible for its incorporation into bone.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 45
    Electronic Resource
    Electronic Resource
    Springer
    Calcified tissue international 24 (1977), S. 143-149 
    ISSN: 1432-0827
    Keywords: Bone ; Periodontal ligament ; Bone resorption ; Aryl sulfatase ; Mineralization
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine , Physics
    Notes: Summary The distribution of aryl sulfatase in the rat periodontal ligament was investigated by ultrastructural histochemistry. In the periodontal ligament aryl sulfatase was localized specifically in osteoclasts and in vicinal perivascular macrophages. Macrophages associated with bone formation did not stain. The authors interpret this specificity as a potential marker for osteoclast differentiation from macrophages — or as a further indication of the capacity of macrophages to modulate their enzymatic complement in response to the environment. To explain the absence of aryl sulfatase in areas of bone formation we suggest that different sulfate esters are mobilized from resorbing and mineralizing matrices, and that only the enzyme associated with bone resorption is histochemically detectable with the artificial substrates currently used.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 46
    Electronic Resource
    Electronic Resource
    Springer
    Calcified tissue international 24 (1977), S. 243-248 
    ISSN: 1432-0827
    Keywords: Paracrystallinity ; Hydroxyapatite ; Bone
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine , Physics
    Notes: Summary X-ray diffraction patterns from oriented bone sections show that the crystalline apatite content of untreated mature cortical bovine bone has, in fact, a paracrystalline structure (i.e., no long range order). There is anisotropy in both lattice distortions and the sizes of the coherently diffracting domains. The paracrystalline mean distance fluctuations, (g) were found to be 1.5 (±0.1)% and 2.9 (±0.2)% for the basal and prism planes respectively, the corresponding paracrystalline sizes being 220 (±20) and 70 (±10) Å. The paracrystalline structure became more ordered above 600°C, suggesting the association of hydroxyl and possibly carbonate and other ions with the paracrystalline structure. The paracrystalline model for bone apatite helps explain anomalies between X-ray and electron microscope measurements of crystal size and also some of the biological functions of the crystalline apatite.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 47
    Electronic Resource
    Electronic Resource
    Springer
    Medical & biological engineering & computing 15 (1977), S. 72-74 
    ISSN: 1741-0444
    Keywords: Bone ; Elasticity ; Mechanical strength
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Chemistry and Pharmacology , Medicine
    Notes: Summary The mechanical properties of canine long bones have been determined. The mean and standard deviation of the maximum load supported by six fresh canine femurs in 3-point bending was 1366±253 N. In all cases, the bones sustained a considerable amount of plastic deformation before failure. The modulus of elasticity (GN/m2), ultimate tensile stress (MN/m2) and yield stress (MN/m2) were 13·86, 108·3 and 88·3 for six humeral specimens and 13·88, 142·1 and 104·0 for 13 tibial specimens, respectively. The tibial specimens showed a statistically significant higher ultimate strength than the humeral specimens.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 48
    Electronic Resource
    Electronic Resource
    Springer
    Medical & biological engineering & computing 15 (1977), S. 207-208 
    ISSN: 1741-0444
    Keywords: Bone ; Instrumentation ; Tensile strength
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Chemistry and Pharmacology , Medicine
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 49
    Electronic Resource
    Electronic Resource
    Springer
    Cell & tissue research 185 (1977), S. 387-397 
    ISSN: 1432-0878
    Keywords: Osteoclasts ; Resorption ; Bone ; Scanning electron microscopy
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine
    Notes: Summary Osteoclasts of the peripheral portions of the endocranial aspect of young rat parietal and frontal bones were studied by scanning electron microscopy of glutaraldehyde fixed, critical point dried specimens. These studies show Osteoclasts to have a much more complicated form than has previously been realised. Extensively branching, elongated, smooth-surfaced cells, which are for the most part elevated above the level of the surrounding bone matrix surface and sometimes above portions of osteoblasts or other osteoclasts, were identified as motile non-resorbing cells. Portions of the former and other entire cells may be embowered in Howship's lacunae, have microvilli on their dorsal surface, and are surrounded by a serrated border of microprojections which have an apparently firm attachment to the matrix surface. Osteoclasts in short term culture show additional free surface ruffles which are not encountered in specimens taken fresh from the animal. No evidence of recruitment of osteoblasts or osteocytes into osteoclasts was found. Disinterred osteocytes retained an ability to migrate from their lacunae on to surrounding bone matrix surface.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...