ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Spektralphotometrie, Atomabsorption  (17)
  • Chromatographie, Gas
  • Springer  (27)
  • Frontiers Media
  • 2015-2019
  • 1975-1979  (27)
  • 1940-1944
  • 1977  (27)
Collection
Keywords
Publisher
  • Springer  (27)
  • Frontiers Media
Years
  • 2015-2019
  • 1975-1979  (27)
  • 1940-1944
Year
  • 1
    ISSN: 1618-2650
    Keywords: Spektralphotometrie, Atomabsorption ; Methanpyrolyse zur Behandlung des Graphitrohr-Atomisators
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 283 (1977), S. 9-14 
    ISSN: 1618-2650
    Keywords: Spektralphotometrie, Atomabsorption ; flammenlos, Störungen
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Summary In the first part different methods for studying interferences of the time dependent signal in flameless AAS are presented with emphasis on factorial designs in experimentation as opposed to the one-factor-at-a-time approach. An example of the statistical computations necessary for interpretation of a multifactor experiment is worked out and discussed in detail with special consideration of the explanation of first-order interactions. The influence of instrumentation upon determinations in the graphite furnace is dealt with in the second part: The temperature in the graphite furnace was measured with a pyrometer, a thermocouple and a Hg-thermometer. The results obtained with the pyrometer were in good agreement with the values given by the manufacturer. The stability of the AAS system was checked and found to be sufficient for the investigation of interferences.
    Notes: Zusammenfassung Im ersten Abschnitt werden die verschiedenen Möglichkeiten zur Untersuchung von Störungen des zeitabhängigen Signals bei der flammenlosen AAS aufgezeigt, wobei besondere Bedeutung den faktoriellen Versuchsplänen im Gegensatz zu einparametrigen Untersuchungen beigemessen wird. Ein Beispiel der statistischen Auswertung zur Interpretation eines Experiments mit mehreren Faktoren wird gebracht, und dabei besonderes Gewicht auf die Erklärung von Wechselwirkungen zwischen zwei Faktoren gelegt. Im zweiten Abschnitt werden die apparativen Einflüsse auf Messungen in der Graphitrohrküvette behandelt. Dazu wurde die Temperatur im Graphitrohr mit einem Pyrometer, einem Thermoelement und einem Quecksilberthermometer gemessen. Die Temperaturen, die mit der pyrometrischen Methode gefunden wurden, stimmen gut mit den vom Hersteller angegebenen Werten überein. Die Stabilität des AAS-Gerätes wurde überprüft: sie reicht für die Durchführung von Interferenzstudien aus.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 283 (1977), S. 97-103 
    ISSN: 1618-2650
    Keywords: Best. von Cadmium ; Spektralphotometrie, Atomabsorption ; flammenlos, Störungen
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Summary Interferences in the flameless determination of cadmium using the HGA 72 were studied for HCl, HNO3, H2SO4, HClO4 and HF and found to be depending on different thermal pretreatment. The interferences of cations were much smaller than for anions. The results are discussed with respect to thermal stability as well as atomization rate of the compositions under investigation. Special emphasis is put upon the presence of interactions between interferents, which in some cases can be used to eliminate interferences.
    Notes: Zusammenfassung Interferenzen, die bei der flammenlosen Bestimmung von Cadmium in der HGA 72 auftreten, wurden bei HCl, HNO3, H2SO4, H3PO4, HClO4 und HF studiert; die AbhÄngigkeit ihres Auftretens von der thermischen Vorbehandlung wird gezeigt. Interferenzen von Kationen sind kleiner. Die Ergebnisse werden im Hinblick auf die thermische StabilitÄt und die Atomisierungsgeschwindigkeit der Proben diskutiert. Besonders betont wird die Gegenwart von Wechselwirkungen zwischen Störungen, die manchmal auch benützt werden können, um Interferenzen auszuschalten.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 283 (1977), S. 183-190 
    ISSN: 1618-2650
    Keywords: Best. von Blei ; Spektralphotometrie, Atomabsorption ; flammenlos, Störungen
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Summary Interferences in the flameless determination of lead using the HGA 72 were studied for HCl, HNO3, H2SO4, H3PO4, HClO4, HF and for a number of cations. In certain instances interferents in just 1000-fold concentration over lead are shown to cause deviations in the lead signal. Many of the interferences are matrix-dependent themselves and can be reduced by matrix variations. Optimization of the thermal pretreatment can be used effectively to reduce random error and/or systematic errors. The thermal stability of lead compounds in the graphite furnace was sufficient for charring procedures up to 900° C for 20 s.
    Notes: Zusammenfassung Interferenzen, die bei der flammenlosen Bestimmung von Blei in der HGA 72 auftreten, wurden bei HCl, HNO3, H2SO4, H3PO4, HClO4, HF und einigen Kationen studiert. In gewissen Fällen reicht ein nur 1000 facher Überschuß des Störions, um Abweichungen vom Signal des Bleistandards hervorzurufen. Da das Auftreten von Interferenzen auch oft matrixabhängig ist, können Matrixvariationen zur Unterdrückung von Interferenzen eingesetzt werden. Die Optimierung des Temperaturprogrammes wird erfolgreich zur Beeinflussung des Zufallsfehlers und/ oder systematischer Fehler herangezogen. In der Graphitrohrküvette reichte die Stabilität der Bleiverbindung aus, um beim Veraschungsschritt die Temperatur bis auf 900° C (20 s) zu steigern.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 283 (1977), S. 337-341 
    ISSN: 1618-2650
    Keywords: Best. von Quecksilber in Luft, Gasen ; Spektralphotometrie, Atomabsorption ; flammenlos
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Summary Mercury is adsorbed on cellulose powder and activated charcoal. The contents of the adsorber are burnt in the oxy-hydrogen flame, and the mercury determined by the flameless atomic absorption procedure. The method is applicable to mercury present as metallic vapour, organo mercurical compounds and particulate matter containing adsorbed mercury compounds. The combustion step eliminates all possible non-atomic absorption interferences in the measuring procedure and ensures quantitative recovery of the mercury from the adsorption material. Quantitative adsorption recovery over a wide range of flow rate from 2–200 l/h allows the use of small battery operated pumps for personal monitoring, or vacuum pumps for high speed and large volume sampling. The range of flow rate makes isokinetic sampling conditions possible.
    Notes: Zusammenfassung Quecksilber wird an Cellulosepulver und Aktivkohle adsorbiert. Der Inhalt des Adsorbers wird in der Wasserstoff-Sauerstoff-Flamme verbrannt und das Quecksilber durch flammenlose Atomabsorption bestimmt. Die Methode erfa\t Quecksilber als Metalldampf, in Form von Organo-Quecksilberverbindungen sowie Quecksilberverbindungen, die an Staubpartikel adsorbiert sind. Die Verbrennung in der Wasserstoff-Sauerstoff-Flamme eliminiert Störungen durch nicht-atomare Absorption bei der AAS-Messung und garantiert die quantitative Erfassung des adsorbierten Quecksilbers. Die quantitative Adsorption über einen gro\en Bereich der Durchflu\geschwindigkeit von 2–200 l/h erlaubt batteriebetriebene Pumpen für die Quecksilbermessung „am Mann“, oder den Einsatz von Vakuumpumpen für die Probenahme bei hoher Durchflu\rate und gro\em Probenvolumen. Der gro\e Bereich der Durchflu\rate gestattet isokinetische Bedingungen für die Probenahme.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 285 (1977), S. 45-46 
    ISSN: 1618-2650
    Keywords: Analyse von Schwefelverbindungen, aliphat ; Chromatographie, Gas ; Zusammenstellung von Retentionsindices
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 285 (1977), S. 107-109 
    ISSN: 1618-2650
    Keywords: Trenn. von Kationen als Diäthyldithiophosphinatochelate ; Chromatographie, Gas
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Das thermogravimetrische und gas-chromatographische Verhalten einiger Bis-(diäthyldithiophosphinato) chelate wird beschrieben. Beispiele für Trennungen und Bestimmungen anorganischer Kationen (Zn, Cd, Co, Ni, Pb) werden gegeben.
    Notes: Abstract The thermogravimetric and gas-chromatographic behaviour of some bis-(diethyldithiophosphinato) chelates is described. Examples for the separation and determination of several inorganic cations (Zn, Cd, Co, Ni, Pb) are given.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    ISSN: 1618-2650
    Keywords: Best. von Kupfer in Legierungen, Stahl ; Spektralphotometrie, Atomabsorption ; Graphitrohrküvette, Spuren
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Die Bestimmung kleiner und kleinster Kupfergehalte in Stahl und anderen Metallegierungen durch Atomabsorptions-Spektralphotometrie wurde untersucht. Dabei konnte festgestellt werden, daß die bei Untersuchungen an wäßrigen Lösungen mit der Flamme auftretenden merklichen Interferenzen durch Begleitelemente völlig ausgeschaltet werden können, wenn das Kupfer mit Pb-DDTC in Chloroform extrahiert und der Extrakt mit der Graphitrohrküvette untersucht wird. Ferner wurde festgestellt, daß die Graphitrohrküvette der Flamme bei den Arbeiten mit organischen Lösungsmitteln erheblich überlegen ist, da von der Art der Lösungsmittel keine Einschränkung des Einsatzbereiches erfolgt. — Die Methoden der kontinuierlichen Veränderungen nach Job und des molaren Verhältnisses nach Yoe u. Jones zur Bestimmung der Komplexzusammensetzung konnten für das System Cu-DDTC auf das Arbeiten mit der Graphitrohrküvette übertragen werden.
    Notes: Abstract The determination of small and smallest amounts of copper in steel and other metal alloys by atomic absorption spectroscopy was investigated. It has been found, that the interferences caused by accompanying elements in the determination in aqueous solution with the flame can be completely removed by extracting the copper with Pb-DDTC in chloroform and determining this extract with the heated graphite atomizer. Moreover, it was recognised, that working with the heated graphite atomizer in organic solutions shows great advantages compared with the flame, because any solvent may be used. The methods of continuous variation by Job and the molar ratio by Yoe and Jones for the determination of the complex stoichiometry were transferred to the system Cu-DDTC by working with the heated graphite atomizer.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 283 (1977), S. 15-21 
    ISSN: 1618-2650
    Keywords: Spurenanalyse ; Silberhalogenide als Spurenfänger für Chelatkomplexe ; Analyse von Mangan, Manganverbindungen ; Spektralphotometrie, Atomabsorption ; Komplexierung von Spuren mit Phenanthrolin, AgJ als Spurenfänger
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Das Nachweisvermögen der Flammen-AAS für Elementspuren wird in Gegenwart der Matrix Mangan erheblich herabgesetzt, so daß eine Abtrennung der Spuren bei der Reinheitskontrolle von Mangan und Manganverbindungen erforderlich ist. Dazu werden die Spuren mit 1,10-Phenanthrolin komplexiert und mit Silberjodid als Spurenfänger angereichert. Durch Erhitzen des abfiltrierten Silberjodids mit HNO3 gelangt man zu nahezu matrixfreien Spurenlösungen von 10 ml, in denen 9 Elemente (Fe, Co, Ni, Cu, Zn, Cd, Pb, Bi und Tl) durch Flammen-AAS bestimmt wurden. Bei Einwaagen von 5–10 g Mangan bzw. Manganverbindungen unterschiedlicher Oxidationsstufen werden — je nach Element — Nachweisgrenzen zwischen 0,01 und 1 ppm erreicht. Durch Aufkonzentrieren der Spurenlösung auf 1 ml und anschließende Bestimmung mit der „Injektionsmethode“ der Flammen-AAS gelangt man zu Nachweisgrenzen von 0,007–0,1 ppm.
    Notes: Abstract The power of detection of flame AAS for trace elements decreases considerably in presence of manganese. For the purity control of manganese and manganese compounds, therefore, it is necessary to separate the traces from the main component of the samples. For that purpose the traces were complexed by 1,10-phenanthroline and coprecipitated by silver iodide as trace collector. To receive a trace solution of 10 ml being free of manganese the filtered AgI was boiled with HNO3. The enriched elements (Fe, Co, Ni, Cu, Zn, Cd, Pb, Bi and Tl) were determined by flame AAS. Using samples of 5 to 10 g of manganese or manganese compounds of different stages of oxidation the limits of detection of the various elements were found to be in a range between 0.01 and 1 ppm. By evaporation of the trace solution down to 1 ml and determination of the traces by the “injection method” of flame AAS limits of detection are obtained between 0.007 and 0.1 ppm.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 283 (1977), S. 303-303 
    ISSN: 1618-2650
    Keywords: Best. von Blei in Boden ; Spektralphotometrie, Atomabsorption ; Matrixeinfluß
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 11
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 284 (1977), S. 19-21 
    ISSN: 1618-2650
    Keywords: Best. von Verunreinigungen in Phosphor ; Spektralphotometrie, Atomabsorption ; Trennungen
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Nach Oxydation der Probe zu H3PO4 mit HNO3/HCl werden die Kationen an einem stark sauren Kationenaustauscher gebunden, mit HCl eluiert und durch AAS bestimmt. Von den häufigsten Verunreinigungen des reinen roten Phosphors werden die Alkali- und Erdalkalielemente sowie die meisten Schwermetalle erfaßt. Fe und As werden nicht abgetrennt, Al nur teilweise. Fe und Al werden durch Extraktion ihrer Oxinate isoliert. As wird aus HBr mit Benzol extrahiert und über die AsH3-Reaktion bestimmt.
    Notes: Abstract After oxidizing the sample to H3PO4 with HNO3/HCl, the cations are absorbed on a strong acid cation exchange resin. They are eluted with HCl and are determined by AAS. Under the most commonly found impurities of high-purity red phosphorus, the alkali and alkaline earth elements and most of the heavy metals can be separated. Fe and As are not separated, Al is partially separated. Fe and Al are isolated by extraction of their 8-quinolinol compounds. As is extracted from HBr with benzene and is determined by means of the AsH3-method.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 12
    ISSN: 1618-2650
    Keywords: Spektralphotometrie, Atomabsorption ; flammenlos, systemat. Fehlerquellen
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Es wird versucht, an Hand ausgewählter Elemente (Fe, Co, Ni, Ag und Cd) schwerwiegende systematische Fehler bei der Bestimmung durch flammenlose Atomabsorptionsspektrometrie aufzuzeigen und deren Ursache zu diskutieren. Neben den Parametern des Temperaturprogramms und des Schutzgasstroms ist die Art und Struktur des Graphits, sowie dessen Reaktivität von entscheidendem Einfluß auf Empfindlichkeit und Nachweisvermögen des Verfahrens. „Depressionen“ bei der Verwendung stark saurer Analysenlösungen werden bestätigt und es wird versucht, diese im Zusammenhang mit der Reaktivität von Graphit zu erklären. An einem vereinfachten Modell wird der Einfluß organischer Lösungsmittel bzw. organischer Lösungen von Komplexbildnern wie Dithizon, NH4-DDTC und APDC auf die Atomisierung untersucht. Es wird diskutiert, ob die dabei registrierten „Depressionen“ Verluste sind, die durch die Bildung flüchtiger metallorganischer Verbindungen bereits bei Temperaturen ab 500° C entstehen. Besonders schwerwiegend sind diese Verlustreaktionen bei Anwesenheit halogenierter Kohlenwasserstoffe, wie an Hand der Reaktionen von Fe, Cd, Co, Ni und Ag mit Chloroform gezeigt werden kann.
    Notes: Abstract With selected elements (Fe, Co, Ni, Ag and Cd), the serious systematic errors inherent in flameless atomic absorption spectrometry are demonstrated and their origins are discussed. Besides the parameters of the temperature program and the inert gas stream, the type and structure of the graphite, as well as its reactivity have a decisive influence on the sensitivities and limits of detection of the technique. Depression of the signal is observed with the use of strongly acid solutions and it has been attempted to explain this in connection with the reactivity of the graphite. The influence of organic solvents and organic solutions of complexes with dithizone, NH4-DDTC and APDC on the atomization have been investigated with simplified examples. It can be presumed that the resulting depression of the signal is due to losses by the formation of volatile metal-organic compounds at temperatures above 500° C. Particularly large are the losses in the presence of hydrocarbon halides as can be demonstrated by the reaction of Fe, Cd, Co, Ni, and Ag with chloroform.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 13
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 284 (1977), S. 41-41 
    ISSN: 1618-2650
    Keywords: Best, von Kupfer, Nickel, Kobalt in Geolog. Material ; Spektralphotometrie, Atomabsorption ; Extraktion
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 14
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 285 (1977), S. 103-106 
    ISSN: 1618-2650
    Keywords: Best. von Brom in organ. Verbindungen ; Chromatographie, Gas ; Mikrographitküvette als Br-spezifischer Detektor
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Summary A micro carbon rod atomizer has been employed for specific and quantitative bromine determinations. This Br-specific gas-chromatographic detector works by help of InBr-bands and measurement at 372.7 nm. The performance of this flame band emission detector (FBD) is demonstrated by calibration curves and the detection limits of 2 examples (ethyl bromide, ethylene dibromide), the latter being 5 and 36 ng of bromine, respectively. The reproducibility has been found to be 4.3%. An example of this detector in comparison with a thermoconductivity detector (TCD) is presented.
    Notes: Zusammenfassung Eine Mikro-Graphit-Küvette wird für spezifische quantitative Brombestimmungen nach der Indium-Methode bei 372,7 nm benützt und in Verbindung mit einem Gas-Chromatographen als Br-spezifischer Detektor eingesetzt. Die Leistungsfähigkeit dieses Detektors wird an 2 Beispielen (Äthylbromid, Dibromäthan) mit Hilfe von Eichkurven, Bestimmung von Nachweisgrenzen u. ä. demonstriert. Die Nachweisgrenzen liegen bei 5 bzw. 36 ng Brom für die 2 genannten Substanzen. Die Reproduzierbarkeit der Messungen liegt bei 4,3%. Ein Beispiel für die Registrierung eines Gemisches verschiedener Substanzen, gemessen mit dem GC + Flammen-Banden-emissions-Detektor (FBD) und zum Vergleich mit einem Wärmeleitfähigkeitsdetektor (TCD), wird dargestellt.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 15
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 285 (1977), S. 238-241 
    ISSN: 1618-2650
    Keywords: Best. von Zuckern, organ. Säuren in Lebensmitteln ; Chromatographie, Gas ; automatisches Aufarbeitungsverfahren
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Summary In the gas-chromatographic analysis of sugars and acids in foodstuffs, isolation and purification of the two types of components is time-consuming and laborious. An automated clean-up procedure, based on ion-exchange, has therefore been developed. A liquid food sample is successively percolated over a cation and anion and a cation exchanger. Sugars and acids are collected under the second and third column, respectively. A time programmer operates a set of pumps and a pneumatic valve system enabling simultaneous regeneration of columns not being eluted. Hence, handling of samples is continuous; each clean-up cycle takes 50 min.
    Notes: Zusammenfassung Eine flüssige Nahrungsmittelprobe wird nacheinander über einen Kationen-, einen Anionen- und einen Kationenaustauscher perkoliert. Die Zucker und die Säuren werden abgetrennt und im Eluat der zweiten bzw. dritten Austauschersäule gefunden. Ein Steuergerät schaltet auf Zeitbasis eine Gruppe von Pumpen und ein System mit pneumatischen Hähnen derart, daß in einem Cyclus (50 min) die Substanzen eluiert und die Säulen regeneriert werden. Anschließend werden die Proben verarbeitet. Einige Ergebnisse verschiedener Nahrungsmittel werden angeführt.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 16
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 286 (1977), S. 219-221 
    ISSN: 1618-2650
    Keywords: Best. von 3-Sulfolen in Sulfolan ; Chromatographie, Gas ; Best. als 1,3-Butadien
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Summary A simple gas-liquid chromatographic method has been developed for determining 3-sulfolene in sulfolane. The method involves thermal decomposition of sulfolene and determination of the 1.3-butadiene evolved, by GLC. Influence of the operating parameters on quantitative decomposition of sulfolene has been studied. The accuracy of the method as studied in the concentration range from 0.05 to 4.0 % (w/v) of 3-sulfolene in sulfolane is found to be within ±3.0%. It is rapid and sensitive down to 10 ppm and has potentialities for on-line applications also.
    Notes: Zusammenfassung Eine einfache gas-chromatographische Methode wurde entwickelt, die auf der thermischen Zersetzung der Probe und der Bestimmung des dabei aus 3-Sulfolen gebildeten 1,3-Butadiens beruht. Der Einfluß der einzelnen Parameter wurde untersucht. Innerhalb eines Konzentrationsbereichs von 0,05–4,0% 3-Sulfolen ergaben sich Fehler von ±3%. Das Verfahren ermöglicht bis herab zu 10 ppm eine schnelle und empfindliche Bestimmung und eignet sich auch zum on-line Betrieb.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 17
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 286 (1977), S. 226-228 
    ISSN: 1618-2650
    Keywords: Best. von Arsen in biolog. Material ; Chromatographie, Gas ; Trimethylsilylarsenat
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Zur gas-chromatographischen Bestimmung von Arsen in biologischem Material wird die Probe in einer Teflon-Bombe aufgeschlossen, das Arsen mit Dithiocarbamat extrahiert, oxidiert und mit Methyltrimethylsilylheptafluorbutyramid silyliert. Die gas-chromatographische Bestimmung läßt sich bis zu einem Arsengehalt von 0,1 ppm ausführen. Die Methode wurde radiochemisch überprüft. Der Einsatz eines flammenphotometrischen Detektors gegenüber einem Flammenionisationsdetektor brachte keine Vorteile.
    Notes: Abstract Organic matter is destroyed by acid oxidation in a Teflon bomb. Arsenic is extracted by dithiocarbamate, oxidized, and silylized by methyl-trimethylsilyl-heptafluorobutyramide. 0.1 ppm and more of arsenic can be determined by gas chromatography of trimethylsilyl arsenate. The method was controlled by radiochemical analysis. For the detection of arsenic, a flame photometric detector is not more advantageous than a flame ionisation detector.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 18
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 286 (1977), S. 253-254 
    ISSN: 1618-2650
    Keywords: Analyse von Dimethylterephthalat ; Chromatographie, Gas ; Rohester
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 19
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 286 (1977), S. 161-190 
    ISSN: 1618-2650
    Keywords: Best. von Celluloseäthergruppen ; Chromatographie, Gas ; Spaltung mit HJ oder HBr, Übersicht
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Es werden Methoden und Apparaturen zur qualitativen und quantitativen Bestimmung von Äthergruppen in Cellulosederivaten mit einer oder mehreren Alkoxyl- und Hydroxyalkylgruppen (C1-nC4) beschrieben. Die Ätherspaltung erfolgt im allgemeinen mit Jodwasserstoffsäure und in Sonderfällen mit Bromwasserstoffsäure. Als Reaktionsprodukte entstehen Monojodalkane und Alkene oder Monobromalkane und Dibromalkane. Diese werden der gas-chromatographischen Trennung unterworfen, über die Retentionszeit identifiziert und durch Titration oder über das Gas-Chromatogramm quantitativ bestimmt.
    Notes: Abstract A report is given on methods and apparatus for the qualitative and quantitative determination of ether groups in cellulose derivatives with one or more alkoxyl and hydroxyalkyl groups (C1-nC4). Ether splitting generally takes place with hydriodic acid and in special cases with hydrobromic acid. The resulting reaction products are monoiodoalkanes and alkenes or monobromoalkanes and dibromoalkanes, which are subjected to gas chromatographic separation and identified via the retention time and quantitatively evaluated by titration or via the gas chromatogram.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 20
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 287 (1977), S. 23-27 
    ISSN: 1618-2650
    Keywords: Best. von Cadmium in Wasser ; Spektralphotometrie, Atomabsorption ; flammenlos, Kulturwasser-Meeresorganismen
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Summary For the determination of cadmium in culture water from toxicological experiments with marine organisms direct flameless atomic absorption spectrophotometry seems to be an appropriate method, because it is less complicated than any combination with an extraction method. Unfortunately, it cannot be applied in the μg·l−1-range without modifications, because matrix effects lead to unacceptable variations in the results. It was found that these difficulties can be overcome by the addition of ammonium peroxodisulphate and sulphuric acid. A routine method basing on this effect has been developed.
    Notes: Zusammenfassung Zur Cadmiumbestimmung in Kulturwasser von toxikologischen Versuchen mit marinen Organismen scheint die direkte flammenlose Atomabsorptions-Spektralphotometrie besonders geeignet zu sein, denn sie ist weniger umständlich als jede Kombination mit einer Extraktionsmethode. Ohne Modifikationen kann die Direktbestimmung jedoch im μg/l-Bereich nicht eingesetzt werden, denn Matrixeffekte bewirken allzu starke Streuungen der Meßergebnisse. Es wird gezeigt, daß ein Zusatz von Ammoniumperoxodisulfat und Schwefelsäure zur Probenlösung eine deutliche Verbesserung bewirkt. Eine Routinemethode wurde entwickelt, bei der von diesem Effekt Gebrauch gemacht wird.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 21
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 287 (1977), S. 112-117 
    ISSN: 1618-2650
    Keywords: Chromatographie, Gas ; Berechnung statistischer Momente, Laplace-Transformation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Summary Statistical moments may be used to augment the information content of stored GC data. Their calculation can be performed either directly by the methods of statistics or by the numerical Laplace Transform. It was found that the direct statistical computation will yield the better results.
    Notes: Zusammenfassung Die statistischen Momente können zur Erhöhung der Aussagekraft von GC-Daten verwendet werden. Diese Berechnungen können auf dem Weg der Statistik direkt oder mittels numerischer Laplace-Transformation durchgeführt werden. Es wurde festgestellt, daß die direkte statistische Bestimmung der numerischen Laplace-Transformation vorzuziehen ist.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 22
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 287 (1977), S. 317-319 
    ISSN: 1618-2650
    Keywords: Best. von Eisen in Biolog. Material ; Spektralphotometrie, Atomabsorption ; Druckaufschluß
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 23
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 288 (1977), S. 62-62 
    ISSN: 1618-2650
    Keywords: Best. von Kupfer, Zink, Nickel, Kobalt, Mangan und Eisen ; Spektralphotometrie, Atomabsorption ; Extraktion mit Phenylmethylbenzoylpyrazolon
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 24
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 288 (1977), S. 191-192 
    ISSN: 1618-2650
    Keywords: Best, von Blei in Pflanzen ; Spektralphotometrie, Atomabsorption ; Reduktion zu metall. Blei
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Summary A new method for determining the lead content of plants has been developed. The dried, ground sample of a plant is first heated in oxygen to decompose the organic material. The lead is then reduced in hydrogen to elemental lead which sublimes and condenses in a capillary. The sublimed lead is dissolved in nitric acid and the lead concentration is determined by atomic absorption spectroscopy.
    Notes: Zusammenfassung Das getrocknete und zerkleinerte Pflanzenmaterial wird im Sauerstoffstrom bei höherer Temperatur verascht. Nach Erhitzen im Wasserstoffstrom wird das Blei verdampft und im Kondensat durch Atomabsorptionsspektroskopie bestimmt.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 25
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 288 (1977), S. 273-276 
    ISSN: 1618-2650
    Keywords: Best. von Vanadium, Elementen in Schmierölen ; Spektralphotometrie, Atomabsorption ; flammenlos, Anpassung der Wickbold-Apparatur
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Die Verbrennungsapparatur nach Wickbold wurde durch Veränderungen am Saugbrenner, am vorderen Flammenrohr, am Kühlsystem und durch Verwendung von Wirbelrohren und eines Überdruckventils der Verbrennung von Erdölprodukten, speziell von gebrauchten Schmierölen, angepaßt. Zur Überprüfung der Apparatur wurde Vanadium in einer synthetischen Testlösung bestimmt. Die Endbestimmung nach der Verbrennung erfolgte durch flammenlose Atomabsorptionsspektrometrie in einer Graphitrohrküvette nach Massmann.
    Notes: Summary The Wickbold combustion apparatus has been modified for decomposition of petroleum products, especially of used lubricating oils. Modifications were made concerning the suction burner, the front of the combustion chamber and the cooling system in conjunction with adding a mixing tube and a pressure limiting valve. The improved apparatus was tested by the vanadium determination in a synthetic sample. After combustion the measurement was performed by flameless atomic absorption spectroscopy using a Massmann graphite tube.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 26
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 288 (1977), S. 281-284 
    ISSN: 1618-2650
    Keywords: Best. von Testosteronestern, Östradiolestern in Injektionslösungen ; Chromatographie, Gas ; ölige Lösung
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Summary A gas-liquid chromatographic method is described for the determination of testosterone and oestradiol esters in oily injection. The separation of the steroids from the injection is performed by partition in the acetonitrile-hexane system. For gas chromatography the oestradiol esters were preliminary transformed to their mono-TMS derivatives. For the separation Dexsil 400 was preferably used as stationary phase. Mestranol was employed as internal standard for quantitation. A complete separation for all the individual components can be achieved within 12 min. The relative standard deviation is in the range of 1–1.5%.
    Notes: Zusammenfassung Die Abtrennung der Steroide aus der Injektionslösung erfolgt durch Extraktion mit Acetonitril und n-Hexan. Zur Gas-Chromatographie werden die Östradiolester in die Mono-trimethylsilylderivate übergeführt. Als stationäre Phase dient vorzugsweise Dexsil 400. Zur quantitativen Bestimmung wird Mestranol als inneren Standard benutzt. Eine vollständige Trennung der Ester läßt sich innerhalb von 12 min erreichen. Die relative Standardabweichung liegt im Bereich von 1–1,5%.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 27
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 288 (1977), S. 344-347 
    ISSN: 1618-2650
    Keywords: Best. von KieselsÄure ; Spektralphotometrie, Atomabsorption ; Auflösung mit Flu\sÄure, Einflu\ von Begleitstoffen
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Zur analytischen Bestimmung der KieselsÄure bzw. des Siliciums durch AAS wird die Möglichkeit der praktisch verlustfreien Auflösung in Flu\sÄure-SalzsÄure in offenen PlastikgefÄ\en über Versuchsergebnisse bestÄtigt. Versuche zur überprüfung von Störungen der KieselsÄurebestimmung in solchen Lösungen durch die Gegenwart von Begleitstoffen zeigten keine Beeinflussungen der Me\ergebnisse. Nach der Anwendung der Analysenmethode zur Siliciumbestimmung in ausgewÄhlten Proben, deren KieselsÄuregehalte in Flu\sÄure löslich sind und ebenso in resistenteren Materialien, wurden die Ergebnisse denen durch klassische Bestimmungen ermittelten gegenübergestellt.
    Notes: Summary Silicic acid resp. silicon can be quantitatively dissolved in a mixture of hydrofluoric acid and hydrochloric acid in open plastic containers. The solution is suitable for quantitative analyses of the silicon content by atomic absorption spectrometry. It can be shown experimentally that the results are not influenced by the presence of other elements in the solution. A comparison has been made between the classical method of silicon analysis and atomic absorption spectrometry using samples containing readily soluble silicic acid and also natural ores which are rather difficult to dissolve.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...