    Publication Date: 2011-08-16
    Description: The pressure sensor for the Tropical Wind Energy conversion and Reference Level Experiment (TWERLE) is described. Key design features of the sensor are: capacitive coupling, reference at midrange, up-down counting, passive oven, storage at flight pressure and prelaunch calibration. Sensor specifications are given which are based on the production results of 440 units. Drift, as estimated from simulated life tests, is 1 mb per 6 months. The overall weight of the sensor, including thermal package, is 180 g.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Journal of Applied Meteorology; 14; Sept
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    facet.materialart.
    Unknown
    In:  Other Sources
    Publication Date: 2011-08-16
    Description: A new approach to seeing in the dark is described which is based on the principles of nonlinear optics employing a crystal such as lithium iodate. A nonlinear optical device capable of producing photons at higher frequencies from lower-frequency incident light is shown to upconvert infrared light directly into visible light. The major advantages of the infrared upconversion process is that it permits the infrared signal to be detected by photon-counting devices presently available for the visible spectral region, and that it can provide sensitivity to infrared radiation without the need for cryogenic cooling of the detector used. Early works on infrared upconversion are reviewed. The development of applications is discussed as to astronomical spectroscopy and infrared image upconversion involving either angular or positional resolution elements. The demonstration of infrared upconversion in rectangular waveguides of single-crystal GaAs by Anderson et al. (1971) indicates future possibilities in upconversion by the use of integrated optics devices.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Optical Sciences Center Newsletter; 9; May 1975
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Publication Date: 2011-08-16
    Description: A tunable, Dicke-switched, infrared heterodyne radiometer (IHR) has been designed, fabricated, tested, and used to observe solar radiation and determine the atmospheric transmissivity in the 9-11-micron spectral band. The IHR provides a spectral resolution of 0.0067 reciprocal cm, a minimum detectable power level of 2.9 times ten to the minus twenty-third power W/Hz, and a temperature resolution of less than 1 K for a source temperature of 1000 K, an IF predetection bandwidth of 100 MHz, and an integration time of 30 s. Detailed design equations and measured IHR performance are presented. The IHR was used to make solar and atmospheric transmission measurements, and a vertical-path atmospheric attenuation of 2.3 dB has been established under favorable weather conditions. The attenuation of solar radiation due to cloud cover and haze has also been investigated.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: IEEE Journal of Quantum Electronics; QE-11; Aug. 197
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Publication Date: 2011-08-16
    Description: The 7.3 kg cameras for the 1976 Viking Mars expedition feature an array of 12 silicon photodiodes, including six spectral bands for color and near-infrared imaging with an angular resolution of 0.12 deg and four focus steps for broadband imaging, with an improved angular resolution of 0.04 deg. The field of view in elevation ranges from 40 deg above to 60 deg below the horizon, and in azimuth ranges to 342.5 deg. The cameras are mounted 0.8 m apart to provide a stereo view of the area accessible to a surface sampler for biological and chemical investigations. The scanning rates are synchronized to the lander data transmission rates of 16000 bits per sec to the Viking orbiters as relay stations and 250 bits per sec directly to earth. However, image data can also be stored on a lander tape recorder. About 10 million bits of image data will be transmitted during most days of the 60-day-long mission planned for each lander.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Space Science Instrumentation; 1; May 1975
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    facet.materialart.
    Unknown
    In:  Other Sources
    Publication Date: 2011-08-16
    Description: The high field fluxgate magnetometer experiment flown aboard the Pioneer XI spacecraft is described. This extremely simple instrument was used to extend the spacecraft's upper-limit measurement capability by approximately an order of magnitude (from 0.14 mT to 1.00 mT) with minimum power and volume requirements. This magnetometer was designed to complement the low-field measurements provided by a helium vector magnetometer and utilizes magnetic ring core sensors with biaxial orthogonal sense coils. The instrument is a single-range, triaxial-fluxgate magnetometer capable of measuring fields of up to 1 mT along each orthogonal axis, with a maximum resolution of 1 microT.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Space Science Instrumentation; 1; May 1975
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Publication Date: 2011-08-16
    Description: The effects of the grid transparency and finite collector size on the values of thermal ion density and temperature determined by the standard RPA (retarding potential analyzer) analysis method are investigated. The current-voltage curves calculated for varying RPA parameters and a given ion mass, temperature, and density are analyzed by the standard RPA method. It is found that only small errors in temperature and density are introduced for an RPA with typical dimensions, and that even when the density error is substantial for nontypical dimensions, the temperature error remains minimum.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Journal of Geophysical Research; 80; June 1
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Publication Date: 2011-08-16
    Description: The phase correction for a Michelson interferometer with misaligned mirrors in converging light is shown to give rise to a quadratic phase shift. In general, the calculation of a spectrum from the measured interferogram needs phase correction. Phase corrections have been well worked out for the cases of a linear phase shift and a phase that is slowly varying. The standard procedures for correcting calculated spectra need to be modified, however, to remove any phase errors resulting from misaligned mirrors.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Applied Optics; 14; June 197
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Publication Date: 2011-08-16
    Description: This paper describes the design and performance of a set of cosmic-ray particle experiments for the Pioneer 10/11 and Helios A/B space missions. These experiments had to be very light-weight, low-power and electronically sophisticated in order to meet the spacecraft and scientific requirements. Both sets of missions use several solid-state detector telescopes to measure protons from 100 KeV to 800 MeV and heavier ions up to Neon at 200 MeV per nucleon. Good performance is required for 7-8 years, and the system must tolerate large vibration loads and ionizing radiation doses up to 500,000 rads.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Publication Date: 2011-08-16
    Description: A method is described in which thermal diffusivity measurements can be made on particulate materials using the identical instrumentation as described in previous papers for measuring thermal conductivity. The measurements for the two properties can be made simultaneously, thus eliminating the changes in conditions when they are made separately. This system has particular application for studies of simulated lunar, planetary, or asteroidal surfaces in which laboratory measurements can be correlated with astronomical observations of thermal inertia. A representative set of data is shown which gives thermal diffusivity and thermal conductivity measurements on a particulate basalt in which the values for each temperature were taken simultaneously. A value for specific heat is calculated for measurements taken at each temperature.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Review of Scientific Instruments; 46; May 1975
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Publication Date: 2011-08-16
    Description: An apparatus is described which is used for the controlled production, characterization, and study of dissociated gases in a microwave discharge at elevated temperatures. A unique feature is the ability to produce and study a microwave discharge plasma in the heated zone. This allows elevated temperature reactions to be studied in high concentrations of dissociated gases. Further, the system permits weight change measurements of specimens in the plasma, thus facilitating reaction rate determinations. Included is a description of a cavity for use on a 50-mm diameter cylindrical reactor. The effects of flow rate, pressure, temperature, power, metal sample, and sampling position on dissociation percentage of oxygen in the apparatus are described as well as a technique for sample temperature measurements in the plasma which permits determination of high temperature recombination coefficients and reaction rates.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: IEEE Transactions on Plasma Science; PS-3; June 197