ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Articles  (1,895)
  • American Institute of Physics (AIP)  (1,395)
  • Wiley  (500)
  • Copernicus
  • 2015-2019
  • 2010-2014  (1,895)
  • 1995-1999
  • 2014  (1,895)
  • Review of Scientific Instruments  (1,395)
  • Journal of Geophysical Research JGR - Solid Earth  (500)
  • 1295
  • 7527
Collection
  • Articles  (1,895)
Publisher
Years
  • 2015-2019
  • 2010-2014  (1,895)
  • 1995-1999
Year
  • 1
    Publication Date: 2014-12-13
    Description: A smart monitoring system for superconducting cable test is proposed with an adaptive current control of a superconducting transformer secondary. The design, based on Fuzzy Gain Scheduling, allows the controller parameters to adapt continuously, and finely, to the working variations arising from transformer nonlinear dynamics. The control system is integrated in a fully digital control loop, with all the related benefits, i.e., high noise rejection, ease of implementation/modification, and so on. In particular, an accurate model of the system, controlled by a Fuzzy Gain Scheduler of the superconducting transformer, was achieved by an experimental campaign through the working domain at several current ramp rates. The model performance was characterized by simulation, under all the main operating conditions, in order to guide the controller design. Finally, the proposed monitoring system was experimentally validated at European Organization for Nuclear Research (CERN) in comparison to the state-of-the-art control system [P. Arpaia, L. Bottura, G. Montenero, and S. Le Naour, “Performance improvement of a measurement station for superconducting cable test,” Rev. Sci. Instrum.83, 095111 (2012)] of the Facility for the Research on Superconducting Cables, achieving a significant performance improvement: a reduction in the system overshoot by 50%, with a related attenuation of the corresponding dynamic residual error (both absolute and RMS) up to 52%.
    Print ISSN: 0034-6748
    Electronic ISSN: 1089-7623
    Topics: Electrical Engineering, Measurement and Control Technology , Physics
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Publication Date: 2014-12-13
    Description: This paper presents a method which uses the characteristics of the etch pits induced in a polyallyl-diglycol-carbonate (PADC) detector of the CR-39/PM-355 type to estimate particle energy. This method is based on the data provided by a semiautomatic system that selects tracks according to two parameters, crater diameters, and mean gray level values. In this paper we used the results of the calibration measurements that were obtained in our laboratory in the period 2000–2014. Combining the information on the two parameters it is possible to determine unambiguously the incident projectile energy values. The paper presents the results of an attempt to estimate the energy resolution of the method when analyzing the tracks produced in the CR-39/PM-355 detector by energetic ions such as alpha particles, protons, and deuterons. We discuss the energy resolution of the measurement of light charged particle energy which is based on the parameters (crater diameter and mean gray level value) of tracks induced in solid state nuclear track detectors of the PADC type.
    Print ISSN: 0034-6748
    Electronic ISSN: 1089-7623
    Topics: Electrical Engineering, Measurement and Control Technology , Physics
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Publication Date: 2014-12-13
    Description: In this work, an automated apparatus for driving single electrostatic probes and acquiring the plasma-related data has been designed and fabricated. The voltage range of the present system is ±110 V with an adjustable voltage step as low as 3 mV. Voltage and current measurements are carried out with high resolution and high accuracy circuits, both based on 16 bit analog-to-digital converters. The code embedded in a micro-controller, schedules the operation of the device and transfers the experimental data to a personal computer. The modular design of the system makes possible its modification and thus increases its adaptability to different plasma setups. Finally, the reliable operation of the entire device is confirmed by tests in Electron Cyclotron Resonance plasma.
    Print ISSN: 0034-6748
    Electronic ISSN: 1089-7623
    Topics: Electrical Engineering, Measurement and Control Technology , Physics
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Publication Date: 2014-12-16
    Description: A pulsed slow-positron beam generated by an electron linear accelerator was directly used for positron annihilation lifetime spectroscopy without any positron storage devices. A waveform digitizer was introduced to simultaneously capture multiple gamma-ray signals originating from positron annihilation events during a single accelerator pulse. The positron pulse was chopped and bunched with the chopper signals also sent to the waveform digitizer. Time differences between the annihilation gamma-ray and chopper peaks were calculated and accumulated as lifetime spectra in a computer. The developed technique indicated that positron annihilation lifetime spectroscopy can be performed in a 20 μ s time window at a pulse repetition rate synchronous with the linear accelerator. Lifetime spectra of a Kapton sheet and a thermally grown SiO 2 layer on Si were successfully measured. Synchronization of positron lifetime measurements with pulsed ion irradiation was demonstrated by this technique.
    Print ISSN: 0034-6748
    Electronic ISSN: 1089-7623
    Topics: Electrical Engineering, Measurement and Control Technology , Physics
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Publication Date: 2014-12-18
    Description: A major goal of nanotechnology is to develop the capability to arrange matter at will by placing individual atoms at desired locations in a predetermined configuration to build a nanostructure with specific properties or function. The scanning tunneling microscope has demonstrated the ability to arrange the basic building blocks of matter, single atoms, in two-dimensional configurations. An array of various nanostructures has been assembled, which display the quantum mechanics of quantum confined geometries. The level of human interaction needed to physically locate the atom and bring it to the desired location limits this atom assembly technology. Here we report the use of autonomous atom assembly via path planning technology; this allows atomically perfect nanostructures to be assembled without the need for human intervention, resulting in precise constructions in shorter times. We demonstrate autonomous assembly by assembling various quantum confinement geometries using atoms and molecules and describe the benefits of this approach.
    Print ISSN: 0034-6748
    Electronic ISSN: 1089-7623
    Topics: Electrical Engineering, Measurement and Control Technology , Physics
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Publication Date: 2014-11-06
    Description: We developed a silicon avalanche photodiode (Si-APD) linear-array detector for use in nuclear resonant scattering experiments using synchrotron X-rays. The Si-APD linear array consists of 64 pixels (pixel size: 100 × 200 μm 2 ) with a pixel pitch of 150 μm and depletion depth of 10 μm. An ultrafast frontend circuit allows the X-ray detector to obtain a high output rate of 〉10 7 cps per pixel. High-performance integrated circuits achieve multichannel scaling over 1024 continuous time bins with a 1 ns resolution for each pixel without dead time. The multichannel scaling method enabled us to record a time spectrum of the 14.4 keV nuclear radiation at each pixel with a time resolution of 1.4 ns (FWHM). This method was successfully applied to nuclear forward scattering and nuclear small-angle scattering on 57 Fe.
    Print ISSN: 0034-6748
    Electronic ISSN: 1089-7623
    Topics: Electrical Engineering, Measurement and Control Technology , Physics
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Publication Date: 2014-11-06
    Description: We describe a nanosecond time-resolved fluorescence spectrometer that acquires fluorescence decay waveforms from each well of a 384-well microplate in 3 min with signal-to-noise exceeding 400 using direct waveform recording. The instrument combines high-energy pulsed laser sources (5–10 kHz repetition rate) with a photomultiplier and high-speed digitizer (1 GHz) to record a fluorescence decay waveform after each pulse. Waveforms acquired from rhodamine or 5-((2-aminoethyl)amino) naphthalene-1-sulfonic acid dyes in a 384-well plate gave lifetime measurements 5- to 25-fold more precise than the simultaneous intensity measurements. Lifetimes as short as 0.04 ns were acquired by interleaving with an effective sample rate of 5 GHz. Lifetime measurements resolved mixtures of single-exponential dyes with better than 1% accuracy. The fluorescence lifetime plate reader enables multiple-well fluorescence lifetime measurements with an acquisition time of 0.5 s per well, suitable for high-throughput fluorescence lifetime screening applications.
    Print ISSN: 0034-6748
    Electronic ISSN: 1089-7623
    Topics: Electrical Engineering, Measurement and Control Technology , Physics
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Publication Date: 2014-11-06
    Description: Diagnostic for investigating and distinguishing different laser ion acceleration mechanisms has been developed and successfully tested. An ion separation wide angle spectrometer can simultaneously investigate three important aspects of the laser plasma interaction: (1) acquire angularly resolved energy spectra for two ion species, (2) obtain ion energy spectra for multiple species, separated according to their charge to mass ratio, along selected axes, and (3) collect laser radiation reflected from and transmitted through the target and propagating in the same direction as the ion beam. Thus, the presented diagnostic constitutes a highly adaptable tool for accurately studying novel acceleration mechanisms in terms of their angular energy distribution, conversion efficiency, and plasma density evolution.
    Print ISSN: 0034-6748
    Electronic ISSN: 1089-7623
    Topics: Electrical Engineering, Measurement and Control Technology , Physics
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Publication Date: 2014-11-07
    Description: μLaue diffraction with a polychromatic X-ray beam can be used to measure strain fields and crystal orientations of micro crystals. The hydrostatic strain tensor can be obtained once the energy profile of the reflections is measured. However, this remains a challenge both on the time scale and reproducibility of the beam position on the sample. In this review, we present a new approach to obtain the spatial and energy profiles of Laue spots by using a pn-junction charge-coupled device, an energy-dispersive area detector providing 3D resolution of incident X-rays. The morphology and energetic structure of various Bragg peaks from a single crystalline Cu micro-cantilever used as a test system were simultaneously acquired. The method facilitates the determination of the Laue spots’ energy spectra without filtering the white X-ray beam. The synchrotron experiment was performed at the BM32 beamline of ESRF using polychromatic X-rays in the energy range between 5 and 25 keV and a beam size of 0.5 μ m × 0.5 μ m. The feasibility test on the well known system demonstrates the capabilities of the approach and introduces the “3D detector method” as a promising tool for material investigations to separate bending and strain for technical materials.
    Print ISSN: 0034-6748
    Electronic ISSN: 1089-7623
    Topics: Electrical Engineering, Measurement and Control Technology , Physics
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Publication Date: 2014-11-07
    Description: A short prototype (847-mm-long) of an Insertion Device (ID) with the dynamic compensation of ID magnetic forces has been designed, built, and tested at the Advanced Photon Source (APS) of the Argonne National Laboratory. The ID magnetic forces were compensated by the set of conical springs placed along the ID strongback. Well-controlled exponential characteristics of conical springs permitted a very close fit to the ID magnetic forces. Several effects related to the imperfections of actual springs, their mounting and tuning, and how these factors affect the prototype performance has been studied. Finally, series of tests to determine the accuracy and reproducibility of the ID magnetic gap settings have been carried out. Based on the magnetic measurements of the ID B eff , it has been demonstrated that the magnetic gaps within an operating range were controlled accurately and reproducibly within ±1 μ m. Successful tests of this ID prototype led to the design of a 3-m long device based on the same concept. The 3-m long prototype is currently under construction. It represents R&D efforts by the APS toward APS Upgrade Project goals as well as the future generation of IDs for the Linac Coherent Light Source (LCLS).
    Print ISSN: 0034-6748
    Electronic ISSN: 1089-7623
    Topics: Electrical Engineering, Measurement and Control Technology , Physics
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 11
    Publication Date: 2014-11-07
    Description: A description is given of an ultra-high vacuum surface-analysis chamber that incorporates an internal cell for performing atomic layer deposition at a pressure of up to ∼1 Torr. The apparatus permits the growth process to be interrupted in stages during which data can be obtained using infrared and x-ray photoemission spectroscopies together with other electron-based techniques. Demonstration results are given for the adsorption of H 2 O on Si (100) at a pressure of ∼0.3 Torr. The system described is generally applicable in the study of any surface reaction under non-high-vacuum conditions in which there is a need for both infrared and electron spectroscopies.
    Print ISSN: 0034-6748
    Electronic ISSN: 1089-7623
    Topics: Electrical Engineering, Measurement and Control Technology , Physics
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 12
    Publication Date: 2014-11-07
    Description: We recently reported the development of a high pressure electrical conductivity probe (HP-ECP) for experimental studies of formation of gas hydrates from electrolytes. The onset of the formation of methane-propane mixed gas hydrate from salt solutions was marked by a temporary upward spike in the electrical conductivity. To further understand hydrate formation a second generation of window-less HP-ECP (MkII), which has a much smaller heat capacity than the earlier version and allows access to faster cooling rates, has been constructed. Using the HP-ECP (MkII) the electrical conductivity signal responses of NaCl solutions upon the formation of ice, tetrahydrofuran hydrates, and methane–propane mixed gas hydrate has been measured. The concentration range of the NaCl solutions was from 1 mM to 3M and the driving AC frequency range was from 25 Hz to 5 kHz. This data has been used to construct an “electrical conductivity response phase diagrams” that summarize the electrical conductivity response signal upon solid formation in these systems. The general trend is that gas hydrate formation is marked by an upward spike in the conductivity at high concentrations and by a drop at low concentrations. This work shows that HP-ECP can be applied in automated measurements of hydrate formation probability distributions of optically opaque samples using the conductivity response signals as a trigger.
    Print ISSN: 0034-6748
    Electronic ISSN: 1089-7623
    Topics: Electrical Engineering, Measurement and Control Technology , Physics
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 13
    Publication Date: 2014-11-07
    Description: In thermomechanical testing of hypersonic materials and structures, direct observation and quantitative strain measurement of the front surface of a test specimen directly exposed to severe aerodynamic heating has been considered as a very challenging task. In this work, a novel quartz infrared heating device with an observation window is designed to reproduce the transient thermal environment experienced by hypersonic vehicles. The specially designed experimental system allows the capture of test article's surface images at various temperatures using an optical system outfitted with a bandpass filter. The captured images are post-processed by digital image correlation to extract full-field thermal deformation. To verify the viability and accuracy of the established system, thermal strains of a chromiumnickel austenite stainless steel sample heated from room temperature up to 600 °C were determined. The preliminary results indicate that the air disturbance between the camera and the specimen due to heat haze induces apparent distortions in the recorded images and large errors in the measured strains, but the average values of the measured strains are accurate enough. Limitations and further improvements of the proposed technique are discussed.
    Print ISSN: 0034-6748
    Electronic ISSN: 1089-7623
    Topics: Electrical Engineering, Measurement and Control Technology , Physics
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 14
    Publication Date: 2014-11-09
    Description: In this study, rock friction ‘stick-slip’ experiments are used to develop constraints on models of earthquake recurrence. Constant-rate loading of bare rock surfaces in high quality experiments produces stick-slip recurrence that is periodic at least to second order. When the loading rate is varied, recurrence is approximately inversely proportional to loading rate. These laboratory events initiate due to a slip rate-dependent process that also determines the size of the stress drop and as a consequence, stress drop varies weakly but systematically with loading rate. This is especially evident in experiments where the loading rate is changed by orders of magnitude, as is thought to be the loading condition of naturally occurring, small repeating earthquakes driven by afterslip, or low-frequency earthquakes loaded by episodic slip. As follows from the previous studies referred to above, experimentally observed stress drops are well described by a logarithmic dependence on recurrence interval that can be cast as a non-linear slip-predictable model. The fault's rate dependence of strength is the key physical parameter. Additionally, even at constant loading rate the most reproducible laboratory recurrence is not exactly periodic, unlike existing friction recurrence models. We present example laboratory catalogs that document the variance and show that in large catalogs, even at constant loading rate, stress drop and recurrence co-vary systematically. The origin of this covariance is largely consistent with variability of the dependence of fault strength on slip rate. Laboratory catalogs show aspects of both slip and time predictability and successive stress drops are strongly correlated indicating a ‘memory’ of prior slip history that extends over at least one recurrence cycle.
    Print ISSN: 0148-0227
    Topics: Geosciences , Physics
    Published by Wiley on behalf of American Geophysical Union (AGU).
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 15
    Publication Date: 2014-11-08
    Description: A simplified method for calibrating atomic force microscope cantilevers was recently proposed by Sader et al. [Rev. Sci. Instrum.83, 103705 (2012); Sec. III D] that relies solely on the resonant frequency and quality factor of the cantilever in fluid (typically air). This method eliminates the need to measure the hydrodynamic function of the cantilever, which can be time consuming given the wide range of cantilevers now available. Using laser Doppler vibrometry, we rigorously assess the accuracy of this method for a series of commercially available cantilevers and explore its performance under non-ideal conditions. This shows that the simplified method is highly accurate and can be easily implemented to perform fast, robust, and non-invasive spring constant calibration.
    Print ISSN: 0034-6748
    Electronic ISSN: 1089-7623
    Topics: Electrical Engineering, Measurement and Control Technology , Physics
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 16
    Publication Date: 2014-11-08
    Description: There exist a number of algorithms to map the phase to amplitude in direct digital synthesis (DDS). For DDS with more than 14 output bits, the Coordinate Rotation Digital Computer (CORDIC) algorithm is well known for its high precision. Also, it is effective in solutions where there is the need of in-phase and quadrature components simultaneously because the algorithm calculates both. In this paper, a Taylor expansion based method was proposed to calculate both in-phase and quadrature at the same time. Numerical simulations for different data format, e.g., double and finite bits, were carried out in Matlab and Quartus, which were followed by the hardware implementation in Field Programmable Gate Array. The results demonstrated that the proposed method possessed higher precision and exhausted less logic elements than the CORDIC algorithm.
    Print ISSN: 0034-6748
    Electronic ISSN: 1089-7623
    Topics: Electrical Engineering, Measurement and Control Technology , Physics
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 17
    Publication Date: 2014-11-08
    Description: We present a Time-to-Digital Converter (TDC) card with a compact form factor, suitable for multichannel timing instruments or for integration into more complex systems. The TDC Card provides 10 ps timing resolution over the whole measurement range, which is selectable from 160 ns up to 10 μ s, reaching 21 ps rms precision, 1.25% LSB rms differential nonlinearity, up to 3 Mconversion/s with 400 mW power consumption. The I/O edge card connector provides timing data readout through either a parallel bus or a 100 MHz serial interface and further measurement information like input signal rate and valid conversion rate (typically useful for time-correlated single-photon counting application) through an independent serial link.
    Print ISSN: 0034-6748
    Electronic ISSN: 1089-7623
    Topics: Electrical Engineering, Measurement and Control Technology , Physics
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 18
    Publication Date: 2014-11-08
    Description: This paper proposes a new pulse-mixing scheme utilizing both pulse-shrinking and pulse-stretching mechanisms to improve the performance of time-to-digital converters (TDCs). The temporal resolution of the conventional pulse-shrinking mechanism is determined by the size ratio between homogeneous and inhomogeneous elements. The proposed scheme which features double-stage operation derives its resolution according to the time difference between pulse-shrinking and pulse-stretching amounts. Thus, it can achieve greater immunity against temperature and ambient variations than that of the single-stage scheme. The circuit area also can be reduced by the proposed pulse-mixing scheme. In addition, this study proposes an improved cyclic delay line to eliminate the undesirable shift in the temporal resolution successfully. Therefore, the effective resolution can be controlled completely by the pulse-mixing unit to improve accuracy. The proposed TDC composed of only one cyclic delay line and one counter is fabricated in a TSMC CMOS 0.35-μm DPQM process. The chip core occupies an extremely small area of 0.02 mm 2 , which is the best among the related works. The experimental result shows that an effective resolution of around 53 ps within ±13% variation over a 0–100 °C temperature range is achieved. The power consumption is 90 μW at a sample rate of 1000 samples/s. In addition to the reduced area, the proposed TDC circuit achieves its resolution with less thermal-sensitivity and better fluctuations caused by process variations.
    Print ISSN: 0034-6748
    Electronic ISSN: 1089-7623
    Topics: Electrical Engineering, Measurement and Control Technology , Physics
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 19
    Publication Date: 2014-11-08
    Description: Real time, in situ , multiframe, diffraction, and imaging measurements on bulk samples under high and ultrahigh strain-rate loading are highly desirable for micro- and mesoscale sciences. We present an experimental demonstration of multiframe transient x-ray diffraction (TXD) along with simultaneous imaging under high strain-rate loading at the Advanced Photon Source beamline 32ID. The feasibility study utilizes high strain-rate Hopkinson bar loading on a Mg alloy. The exposure time in TXD is 2–3 μs, and the frame interval is 26.7–62.5 μs. Various dynamic deformation mechanisms are revealed by TXD, including lattice expansion or compression, crystal plasticity, grain or lattice rotation, and likely grain refinement, as well as considerable anisotropy in deformation. Dynamic strain fields are mapped via x-ray digital image correlation, and are consistent with the diffraction measurements and loading histories.
    Print ISSN: 0034-6748
    Electronic ISSN: 1089-7623
    Topics: Electrical Engineering, Measurement and Control Technology , Physics
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 20
    Publication Date: 2014-11-08
    Description: We report techniques developed to utilize three-dimensional momentum information as feedback in adaptive femtosecond control of molecular dynamics. Velocity map imaging is used to obtain the three-dimensional momentum map of the dissociating ions following interaction with a shaped intense ultrafast laser pulse. In order to recover robust feedback information, however, the two-dimensional momentum projection from the detector must be inverted to reconstruct the full three-dimensional momentum of the photofragments. These methods are typically slow or require manual inputs and are therefore accomplished offline after the images have been obtained. Using an algorithm based upon an “onion-peeling” (also known as “back projection”) method, we are able to invert 1040 × 1054 pixel images in under 1 s. This rapid inversion allows the full photofragment momentum to be used as feedback in a closed-loop adaptive control scheme, in which a genetic algorithm tailors an ultrafast laser pulse to optimize a specific outcome. Examples of three-dimensional velocity map image based control applied to strong-field dissociation of CO and O 2 are presented.
    Print ISSN: 0034-6748
    Electronic ISSN: 1089-7623
    Topics: Electrical Engineering, Measurement and Control Technology , Physics
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 21
    Publication Date: 2014-11-08
    Description: In order to improve the atom spin gyroscope's operational accuracy and compensate the random error caused by the nonlinear and weak-stability characteristic of the random atomic spin gyroscope (ASG) drift, the hybrid random drift error model based on autoregressive (AR) and genetic programming (GP) + genetic algorithm (GA) technique is established. The time series of random ASG drift is taken as the study object. The time series of random ASG drift is acquired by analyzing and preprocessing the measured data of ASG. The linear section model is established based on AR technique. After that, the nonlinear section model is built based on GP technique and GA is used to optimize the coefficients of the mathematic expression acquired by GP in order to obtain a more accurate model. The simulation result indicates that this hybrid model can effectively reflect the characteristics of the ASG's random drift. The square error of the ASG's random drift is reduced by 92.40%. Comparing with the AR technique and the GP + GA technique, the random drift is reduced by 9.34% and 5.06%, respectively. The hybrid modeling method can effectively compensate the ASG's random drift and improve the stability of the system.
    Print ISSN: 0034-6748
    Electronic ISSN: 1089-7623
    Topics: Electrical Engineering, Measurement and Control Technology , Physics
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 22
    Publication Date: 2014-11-08
    Description: This paper describes the design and performance of an extremely low-noise differential transimpedance amplifier, which takes its two inputs from separate photodiodes. The amplifier was planned to serve as the front-end electronics for a highly sensitive shadow-displacement sensing system, aimed at detecting very low-level “Violin-Mode” ( VM ) oscillations in 0.4 mm diameter by 600 mm long fused-silica suspension fibres. Four such highly tensioned fibres support the 40 kg test-masses/mirrors of the Advanced Laser Interferometer Gravitational wave Observatory interferometers. This novel design of amplifier incorporates features which prevent “noise-gain peaking” arising from large area photodiode (and cable) capacitances, and which also usefully separate the DC and AC photocurrents coming from the photodiodes. In consequence, the differential amplifier was able to generate straightforwardly two DC outputs, one per photodiode, as well as a single high-gain output for monitoring the VM oscillations—this output being derived from the difference of the photodiodes’ two, naturally anti-phase, AC photocurrents. Following a displacement calibration, the amplifier's final VM signal output was found to have an AC displacement responsivity at 500 Hz of (9.43 ± 1.20) MV(rms) m −1 (rms), and, therefore, a shot-noise limited sensitivity to such AC shadow- (i.e., fibre-) displacements of (69 ± 13) picometres/√Hz at this frequency, over a measuring span of ±0.1 mm.
    Print ISSN: 0034-6748
    Electronic ISSN: 1089-7623
    Topics: Electrical Engineering, Measurement and Control Technology , Physics
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 23
    Publication Date: 2014-11-04
    Description: We present a novel high-precision two-way optic-fiber time transfer scheme. The Inter-Range Instrumentation Group (IRIG-B) time code is modified by increasing bit rate and defining new fields. The modified time code can be transmitted directly using commercial optical transceivers and is able to efficiently suppress the effect of the Rayleigh backscattering in the optical fiber. A dedicated codec (encoder and decoder) with low delay fluctuation is developed. The synchronization issue is addressed by adopting a mask technique and combinational logic circuit. Its delay fluctuation is less than 27 ps in terms of the standard deviation. The two-way optic-fiber time transfer using the improved codec scheme is verified experimentally over 2 m to100 km fiber links. The results show that the stability over 100 km fiber link is always less than 35 ps with the minimum value of about 2 ps at the averaging time around 1000 s. The uncertainty of time difference induced by the chromatic dispersion over 100 km is less than 22 ps.
    Print ISSN: 0034-6748
    Electronic ISSN: 1089-7623
    Topics: Electrical Engineering, Measurement and Control Technology , Physics
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 24
    Publication Date: 2014-11-04
    Description: Neutrons spectra from most of known sources require being collimated for numerous applications; among them one is the Neutron Activation Analysis. High energy neutrons are collimated through a mechanical procedure as one of the most promising methods. The output energy of the neutron beam depends on the velocity of the rotating Polyethylene disks. The collimated neutrons are then measured by an innovative detection technique with high accuracy.
    Print ISSN: 0034-6748
    Electronic ISSN: 1089-7623
    Topics: Electrical Engineering, Measurement and Control Technology , Physics
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 25
    Publication Date: 2014-11-05
    Print ISSN: 0034-6748
    Electronic ISSN: 1089-7623
    Topics: Electrical Engineering, Measurement and Control Technology , Physics
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 26
    Publication Date: 2014-11-05
    Description: Acceleration in development of additional conventional hydropower requires tools and methods to perform laboratory and in-field validation of turbine performance and fish passage claims. The new-generation Sensor Fish has been developed with more capabilities to accommodate a wider range of users over a broader range of turbine designs and operating environments. It provides in situ measurements of three-dimensional (3D) linear accelerations, 3D rotational velocities, 3D orientation, pressure, and temperature at a sampling frequency of 2048 Hz. It also has an automatic floatation system and built-in radio-frequency transmitter for recovery. The relative errors of the pressure, acceleration, and rotational velocity were within ±2%, ±5%, and ±5%, respectively. The accuracy of orientation was within ±4° and accuracy of temperature was ±2 °C. The new-generation Sensor Fish is becoming a major technology and being deployed for evaluating the conditions for fish passage of turbines or other hydraulic structures in both the United States and several other countries.
    Print ISSN: 0034-6748
    Electronic ISSN: 1089-7623
    Topics: Electrical Engineering, Measurement and Control Technology , Physics
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 27
    Publication Date: 2014-12-14
    Description: We derive equations for HTI and orthorhombic symmetries to analyze fluid substitution effects in porous fractured media. The derivations are based on the anisotropic Gassmann equation and linear slip theory. We assess the influence of fluid substitution (gas, brine, and oil), on elastic moduli, velocities, anisotropy, and azimuthal amplitude variations. We find that in the direction normal to fractures, P-wave moduli increase as much as 56% and P-wave velocity increases up to 19% for gas-to-brine substitution. For the direction parallel to fractures, P-wave velocity remains almost constant when porosity is low (5%), but can increase up to 4% if porosity is high (25%). Since P-waves in two different directions have different sensitivities to fluids and fractures, the Thomsen's parameters (defined for HTI and orthorhombic symmetries), ε and δ , are sensitive to fluid types and fractures. We also found that δ is sensitive to porosity for liquid saturation, but insensitive to porosity for the case of gas saturation. Gassmann assumes (and as has been observed) that shear modulus does not depend on fluids. And we observe no changes in shear-wave splitting ( γ ) for different fluids. The azimuthal amplitude variation is dependent on fluid types, fractures and porosity. We observe up to 12% increase in azimuthal amplitude variation for low porosity gas sands after brine saturation, and 6% decrease for high porosity gas sands. We find that the percentage changes in gas-to-oil substitution are about half that of the gas-to-brine case. The equations we have derived provide a useful tool to quantitatively evaluate the effects of fluid substitution on seismic anisotropy.
    Print ISSN: 0148-0227
    Topics: Geosciences , Physics
    Published by Wiley on behalf of American Geophysical Union (AGU).
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 28
    Publication Date: 2014-12-14
    Description: In the central part of Fennoscandia the crust is currently rising, because of the delayed response of the viscous mantle to melting of the Late Pleistocene ice sheet. This process, called Glacial Isostatic Adjustment (GIA), causes a negative anomaly in the present-day static gravity field as isostatic equilibrium has not been reached yet. Several studies have tried to use this anomaly as a constraint on models of GIA, but the uncertainty in crustal and upper mantle structures has not been fully taken intoaccount. Therefore, our aim is to revisit this using improved crustal models and compensation techniques. We find that, in contrast with other studies, the effect of crustal anomalies on the gravity field cannot be effectively removed, because of uncertainties in the crustal and upper mantle density models. Our second aim is to estimate the effects on geophysical models, which assume isostatic equilibrium, after correcting the observed gravity field with numerical models for GIA. We show that correcting for GIA in geophysical modelling can give changes of several km in the thickness of structural layers of modeled lithosphere, which is a small but significant correction. Correcting the gravity field for GIA prior to assuming isostatic equilibrium and inferring density anomalies might be relevant in other areas with ongoing post-glacial rebound such as North America and the polar regions.
    Print ISSN: 0148-0227
    Topics: Geosciences , Physics
    Published by Wiley on behalf of American Geophysical Union (AGU).
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 29
    Publication Date: 2014-12-14
    Description: Large variability of earthquake stress drops and scaled energy has been commonly reported in the literature, but it is difficult to assess how much of this variability is caused by underlying physical source processes rather than simply observational uncertainties. Here, we examine a variety of dynamically realistic rupture scenarios for circular and elliptical faults and investigate to what extent the variability in seismically estimated stress drops and scaled energy comes from differences in source geometry, rupture directivity, and rupture speeds. We numerically simulate earthquake source scenarios using a cohesive-zone model with the small-scale yielding limit, where the solution approaches a singular crack model with spontaneous healing of slip. Compared to symmetrical circular source models, asymmetrical models result in larger variability of estimated corner frequencies and scaled energy over the focal sphere. The general behavior of the spherical averages of corner frequencies and scaled energy in the subshear regime extends to the supershear regime, although shear Mach waves generated by the propagation of supershear rupture lead to much higher corner-frequency and scaled-energy estimates locally. Our results suggest that at least a factor of two difference in the spherical average of corner frequencies is expected in observational studies simply from variability in source characteristics almost independent of the actual stress drops, translating into a factor ofeight difference in estimated stress drops. Furthermore, radiation efficiency estimates derived from observed seismic spectra should not be directly interpreted as describing rupture properties unless there are independent constraints on rupture speed and geometry.
    Print ISSN: 0148-0227
    Topics: Geosciences , Physics
    Published by Wiley on behalf of American Geophysical Union (AGU).
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 30
    Publication Date: 2014-12-16
    Description: High-speed atomic force microscopy has attracted much attention due to its unique capability of visualizing nanoscale dynamic processes at a solid/liquid interface. However, its usability and resolution have yet to be improved. As one of the solutions for this issue, here we present a design of a high-speed Z -tip scanner with screw holding mechanism. We perform detailed comparison between designs with different actuator size and screw arrangement by finite element analysis. Based on the design giving the best performance, we have developed a Z tip scanner and measured its performance. The measured frequency response of the scanner shows a flat response up to ∼10 kHz. This high frequency response allows us to achieve wideband tip-sample distance regulation. We demonstrate the applicability of the scanner to high-speed atomic-resolution imaging by visualizing atomic-scale calcite crystal dissolution process in water at 2 s/frame.
    Print ISSN: 0034-6748
    Electronic ISSN: 1089-7623
    Topics: Electrical Engineering, Measurement and Control Technology , Physics
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 31
    Publication Date: 2014-12-16
    Description: A suspension system of classical geophone was developed, adopting multiple pairs of leaf springs as a substitute for one pair. The finite element analysis was used as the solving means, and the results indicated that the geophone performance with developed suspension system was more favorable than that with conventional suspension system. First, the operating broadband of the improved geophone was wider than that of the conventional geophone. Second, the distortion of output signal for a geophone was slightly reduced, which was usually enlarged with improving the ratio of spurious resonant frequency to natural frequency.
    Print ISSN: 0034-6748
    Electronic ISSN: 1089-7623
    Topics: Electrical Engineering, Measurement and Control Technology , Physics
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 32
    Publication Date: 2014-12-16
    Description: A liquid membrane electrochemical etching process for preparing nano-tips is proposed by the introduction of buoyant force to the lower tip, in which the lower portion of the anodic wire is immersed into a floating layer. A mathematical model of this method is derived. Both calculation and experimental results demonstrate that the introduction of buoyant force can significantly decrease the tip radius. The lubricating oil and deionized water floating layers were tested for the processing of nano-tips. Further, high-aspect-ratio nano-electrodes were prepared by applying a relative vertical movement to the anodic wire.
    Print ISSN: 0034-6748
    Electronic ISSN: 1089-7623
    Topics: Electrical Engineering, Measurement and Control Technology , Physics
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 33
    Publication Date: 2014-12-16
    Description: Construction and characterization of a multichannel photodiode detector based on commercially available components with high signal to noise of ∼10 6 and a rapid frame rate, suitable for time resolved femtosecond spectroscopy with high repetition femtosecond sources, is presented.
    Print ISSN: 0034-6748
    Electronic ISSN: 1089-7623
    Topics: Electrical Engineering, Measurement and Control Technology , Physics
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 34
    Publication Date: 2014-12-16
    Description: The neutron imaging system at the National Ignition Facility (NIF) is an important diagnostic tool for measuring the two-dimensional size and shape of the neutrons produced in the burning deuterium-tritium plasma during the stagnation stage of inertial confinement fusion implosions. Since the neutron source is small (∼100 μ m) and neutrons are deeply penetrating (〉3 cm) in all materials, the apertures used to achieve the desired 10- μ m resolution are 20-cm long, triangular tapers machined in gold foils. These gold foils are stacked to form an array of 20 apertures for pinhole imaging and three apertures for penumbral imaging. These apertures must be precisely aligned to accurately place the field of view of each aperture at the design location, or the location of the field of view for each aperture must be measured. In this paper we present a new technique that has been developed for the measurement and characterization of the precise location of each aperture in the array. We present the detailed algorithms used for this characterization and the results of reconstructed sources from inertial confinement fusion implosion experiments at NIF.
    Print ISSN: 0034-6748
    Electronic ISSN: 1089-7623
    Topics: Electrical Engineering, Measurement and Control Technology , Physics
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 35
    Publication Date: 2014-12-16
    Description: Laser-based time-domain thermoreflectance (TDTR) and frequency-domain thermoreflectance (FDTR) techniques are widely used for investigating thermal transport at micro- and nano-scales. We demonstrate that data obtained in TDTR measurements can be represented in a frequency-domain form equivalent to FDTR, i.e., in the form of a surface temperature amplitude and phase response to time-harmonic heating. Such a representation is made possible by using a large TDTR delay time window covering the entire pulse repetition interval. We demonstrate the extraction of frequency-domain data up to 1 GHz from TDTR measurements on a sapphire sample coated with a thin layer of aluminum, and show that the frequency dependencies of both the amplitude and phase responses agree well with theory. The proposed method not only allows a direct comparison of TDTR and FDTR data, but also enables measurements at high frequencies currently not accessible to FDTR. The frequency-domain representation helps uncover aspects of the measurement physics which remain obscured in a traditional TDTR measurement, such as the importance of modeling the details of the heat transport in the metal transducer film for analyzing high frequency responses.
    Print ISSN: 0034-6748
    Electronic ISSN: 1089-7623
    Topics: Electrical Engineering, Measurement and Control Technology , Physics
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 36
    Publication Date: 2014-12-16
    Description: The ability to synchronize a femtosecond laser to x-ray pulses is crucial for performing ultrafast time-resolved x-ray scattering experiments at synchrotrons. Conventionally, the task has been achieved by locking a harmonic frequency of the laser oscillator to the storage ring master radio-frequency (RF). However, when the frequency mismatch between the two sources cannot be compensated by small adjustments to the laser cavity length, synchronization to a harmonic frequency requires modifying the optical components of the laser system. We demonstrate a novel synchronization scheme, which is a flexible alternative for synchronizing these two sources operating at arbitrarily different frequencies. First, we find the greatest common divisor (GCD) of the two frequencies that is still within the limited tuning range of the laser cavity length. The GCD is generated by dividing down from the storage ring RF, and is separately multiplied up to provide a feedback signal for synchronizing the laser cavity. Unique to our scheme, the GCD also serves as a harmonic RF source for the laser amplifier such that only laser oscillator pulses at fixed integer multiples of the storage ring RF are selected for amplification and delivery to experiments. Our method is implemented at the Photon Test Facility beamline of Pohang Light Source where timing-jitter less than 4 ps (r.m.s.) is measured using a new shot-to-shot method.
    Print ISSN: 0034-6748
    Electronic ISSN: 1089-7623
    Topics: Electrical Engineering, Measurement and Control Technology , Physics
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 37
    Publication Date: 2014-12-16
    Description: A semi-adiabatic isoperibol solution calorimeter has been indigenously developed. The measurement system comprises modules for sensitive temperature measurement probe, signal processing, data collection, and joule calibration. The sensitivity of the temperature measurement module was enhanced by using a sensitive thermistor coupled with a lock-in amplifier based signal processor. A microcontroller coordinates the operation and control of these modules. The latter in turn is controlled through personal computer (PC) based custom made software developed with LabView. An innovative summing amplifier concept was used to cancel out the base resistance of the thermistor. The latter was placed in the dewar. The temperature calibration was carried out with a standard platinum resistance (PT100) sensor coupled with an 8½ digit multimeter. The water equivalent of this calorimeter was determined by using electrical calibration with the joule calibrator. The experimentally measured values of the quantum of heat were validated by measuring heats of dissolution of pure KCl (for endotherm) and tris (hydroxyl methyl) amino-methane (for exotherm). The uncertainity in the measurements was found to be within ±3%.
    Print ISSN: 0034-6748
    Electronic ISSN: 1089-7623
    Topics: Electrical Engineering, Measurement and Control Technology , Physics
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 38
    Publication Date: 2014-12-17
    Description: A biomedical microwave tomography system with 3D-imaging capabilities has been constructed and translated to the clinic. Updates to the hardware and reconfiguration of the electronic-network layouts in a more compartmentalized construct have streamlined system packaging. Upgrades to the data acquisition and microwave components have increased data-acquisition speeds and improved system performance. By incorporating analog-to-digital boards that accommodate the linear amplification and dynamic-range coverage our system requires, a complete set of data (for a fixed array position at a single frequency) is now acquired in 5.8 s. Replacement of key components (e.g., switches and power dividers) by devices with improved operational bandwidths has enhanced system response over a wider frequency range. High-integrity, low-power signals are routinely measured down to −130 dBm for frequencies ranging from 500 to 2300 MHz. Adequate inter-channel isolation has been maintained, and a dynamic range 〉110 dB has been achieved for the full operating frequency range (500–2900 MHz). For our primary band of interest, the associated measurement deviations are less than 0.33% and 0.5° for signal amplitude and phase values, respectively. A modified monopole antenna array (composed of two interwoven eight-element sub-arrays), in conjunction with an updated motion-control system capable of independently moving the sub-arrays to various in-plane and cross-plane positions within the illumination chamber, has been configured in the new design for full volumetric data acquisition. Signal-to-noise ratios (SNRs) are more than adequate for all transmit/receive antenna pairs over the full frequency range and for the variety of in-plane and cross-plane configurations. For proximal receivers, in-plane SNRs greater than 80 dB are observed up to 2900 MHz, while cross-plane SNRs greater than 80 dB are seen for 6 cm sub-array spacing (for frequencies up to 1500 MHz). We demonstrate accurate recovery of 3D dielectric property distributions for breast-like phantoms with tumor inclusions utilizing both the in-plane and new cross-plane data.
    Print ISSN: 0034-6748
    Electronic ISSN: 1089-7623
    Topics: Electrical Engineering, Measurement and Control Technology , Physics
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 39
    Publication Date: 2014-12-17
    Description: In situ x-ray absorption spectroscopy (XAS) provides element-specific characterization of both crystalline and amorphous phases and enables direct correlations between electrochemical performance and structural characteristics of cathode and anode materials. In situ XAS measurements are very demanding to the design of the experimental setup. We have developed a sample chamber that provides electrical connectivity and inert atmosphere for operating electrochemical cells and also accounts for x-ray interactions with the chamber and cell materials. The design of the sample chamber for in situ measurements is presented along with example XAS spectra from anode materials in operating pouch cells at the Zn and Sn K-edges measured in fluorescence and transmission modes, respectively.
    Print ISSN: 0034-6748
    Electronic ISSN: 1089-7623
    Topics: Electrical Engineering, Measurement and Control Technology , Physics
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 40
    Publication Date: 2014-12-17
    Description: The light intensity of 6 Li III line spectrum at λ = 516.7 nm was observed during 6 Li 3+ beam tuning at the Hyper-Electron Cyclotron Resonance (ECR) ion source. Separation of ion species of the same charge to mass ratio with an electromagnetic mass analyzer is known to be an exceptionally complex process. However, 6 Li III line intensity observation conducted in this study gives new insights into its simplification of this process. The light intensity of 6 Li III line spectrum from the ECR plasma was found to have a strong correlation with the extracted 6 Li 3+ beam intensity from the RIKEN Azimuthal Varying Field cyclotron.
    Print ISSN: 0034-6748
    Electronic ISSN: 1089-7623
    Topics: Electrical Engineering, Measurement and Control Technology , Physics
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 41
    Publication Date: 2014-12-17
    Description: The paper describes a time- and angle-resolved photoemission apparatus consisting of a hemispherical analyzer and a pulsed laser source. We demonstrate 1.48-eV pump and 5.92-eV probe measurements at the ⩾10.5-meV and ⩾240-fs resolutions by use of fairly monochromatic 170-fs pulses delivered from a regeneratively amplified Ti:sapphire laser system operating typically at 250 kHz. The apparatus is capable to resolve the optically filled superconducting peak in the unoccupied states of a cuprate superconductor, Bi 2 Sr 2 CaCu 2 O 8 + δ . A dataset recorded on Bi(111) surface is also presented. Technical descriptions include the followings: A simple procedure to fine-tune the spatio-temporal overlap of the pump-and-probe beams and their diameters; achieving a long-term stability of the system that enables a normalization-free dataset acquisition; changing the repetition rate by utilizing acoustic optical modulator and frequency-division circuit.
    Print ISSN: 0034-6748
    Electronic ISSN: 1089-7623
    Topics: Electrical Engineering, Measurement and Control Technology , Physics
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 42
    Publication Date: 2014-12-06
    Description: Ellipsometry is one of the standard methods for observation of glass transition in thin polymer films. This work proposes that sensitivity of the method to surface morphology can complicate manifestation of the transition in a few nm thick samples. Two possible mechanisms of free surface roughening in the vicinity of glass transition are discussed: roughening due to lateral heterogeneity and roughening associated with thermal capillary waves. Both mechanisms imply an onset of surface roughness in the glass transition temperature range, which affects the experimental data in a way that shifts apparent glass transition temperature. Effective medium approximation models are used to introduce surface roughness into optical calculations. The results of the optical modeling for a 5 nm thick polystyrene film on silicon are presented.
    Print ISSN: 0034-6748
    Electronic ISSN: 1089-7623
    Topics: Electrical Engineering, Measurement and Control Technology , Physics
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 43
    Publication Date: 2014-12-06
    Description: Investigations of emission of harmonics from argon gas jet irradiated by 700 fs, 5 mJ pulses from a KrF laser are presented. Harmonics conversion was optimized by varying the experimental geometry and the nozzle size. For the collection of the harmonic radiation silicon and solar-blind diamond semiconductor detectors equipped with charge preamplifiers were applied. The possibility of using a single-crystal CVD diamond detector for separate measurement of the 3rd harmonic in the presence of a strong pumping radiation was explored. Our experiments show that the earlier suggested 0.7% conversion efficiency can really be obtained, but only in the case when phase matching is optimized with an elongated gas target length corresponding to the length of coherence.
    Print ISSN: 0034-6748
    Electronic ISSN: 1089-7623
    Topics: Electrical Engineering, Measurement and Control Technology , Physics
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 44
    Publication Date: 2014-11-06
    Description: Petrophysical properties of rocks and their applicability at larger scale are a challenging topic in Earth sciences. Petrophysical properties of rocks are severely affected by: boundary conditions, rock fabric/microstructure, and tectonics that require a multi-scale approach to be properly defined. Here we: (1) report laboratory measurements of density, porosity, permeability and P-wave velocities at increasing confining pressure conducted on Miocene foredeep sandstones (Frosinone Fm.); (2) compare the laboratory results with larger-scale geophysical investigations; (3) discuss the effect of thrusting on the properties of sandstones. At ambient pressure, laboratory porosity varied from 2.2% to 13.8% and P-wave velocities (Vp) from 1.5 km/s to 2.7 km/s. The P-wave velocity increased with confining pressure, reaching between 3.3 km/s to 4.7 km/s at 100 MPa. In situ Vp profiles, measured using sonic logs, matched the ultrasonic laboratory measurement well. The permeability varied between 1.4 × 10 -15  m 2 to 3.9 × 10 -15  m 2 and was positively correlated with porosity. The porosity and permeability of samples taken at various distances to the Olevano-Antrodoco fault plane progressively decreased with distance while P-wave velocity increased. At about 1 km from the fault plane, the relative variations reached 43%, 65% and 20% for porosity, permeability and P-wave velocity, respectively. This suggests that tectonic loading changed the petrophysical properties inherited from sedimentation and diagenesis. Using field constraints and assuming overburden-related inelastic compaction in the proximity of the fault plane, we conclude that the fault reached the mechanical condition for rupture in compression at differential stress of 64.8 MPa at a depth of 1500 m.
    Print ISSN: 0148-0227
    Topics: Geosciences , Physics
    Published by Wiley on behalf of American Geophysical Union (AGU).
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 45
    Publication Date: 2014-12-06
    Description: The RF properties of an accelerating structure, and the pulse structure and charge per bunch in the electron beam propagating through it are important parameters that determine the impact of beam loading in the structure. The injector linac of the Compact Ultrafast Terahertz Free-Electron Laser (CUTE-FEL) has been operated with two different pulse structures during initial commissioning experiments and the effect of beam loading on the accelerated electron beam parameters has been studied analytically for these two pulse structures. This paper discusses the analytical study of beam loading in a Standing Wave, Plane Wave Transformer linac employed in the CUTE-FEL setup, and a possible technique for its compensation for the electron beam parameters of the CUTE-FEL. A parametric study has been performed to study beam loading for different beam currents and to optimize injection time of the electron beam to compensate beam loading. Results from the parametric study have also been used to explain previously observed results from acceleration experiments in the CUTE-FEL setup.
    Print ISSN: 0034-6748
    Electronic ISSN: 1089-7623
    Topics: Electrical Engineering, Measurement and Control Technology , Physics
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 46
    Publication Date: 2014-12-06
    Description: We report the design, construction, and performances of a microwave (MW) heating device for laboratory experiments with non-contact, homogeneous internal heating. The device generates MW radiation at 2.47 GHz from a commercial magnetron supplied by a pulsed current inverter using proprietary, feedback based command and control hardware and software. Specially designed MW launchers direct the MW radiation into the sample through a MW homogenizer, devised to even the MW power distribution into the sample's volume. An adjustable MW circuit adapts the MW generator to the load (i.e., the sample) placed in the experiment chamber. Dedicated heatsinks maintain the MW circuits at constant temperature throughout the experiment. Openings for laser scanning for image acquisition with a CCD camera and for the cooling circuits are protected by special MW filters. The performances of the device are analyzed in terms of heating uniformity, long term output power stability, and load matching. The device is used for small scale experiments simulating Earth's mantle convection. The 30 × 30 × 5 cm 3 convection tank is filled with a water‑based viscous fluid. A uniform and constant temperature is maintained at the upper boundary by an aluminum heat exchanger and adiabatic conditions apply at the tank base. We characterize the geometry of the convective regime as well as its bulk thermal evolution by measuring the velocity field by Particle Image Velocimetry and the temperature field by using Thermochromic Liquid Crystals.
    Print ISSN: 0034-6748
    Electronic ISSN: 1089-7623
    Topics: Electrical Engineering, Measurement and Control Technology , Physics
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 47
    Publication Date: 2014-12-06
    Description: This paper announces the implementation of a long wavelength infrared camera to obtain high-speed thermal images of an aircraft engine's in-service thermal barrier coated turbine blades. Long wavelength thermal images were captured of first-stage blades. The achieved temporal and spatial resolutions allowed for the identification of cooling-hole locations. The software and synchronization components of the system allowed for the selection of any blade on the turbine wheel, with tuning capability to image from leading edge to trailing edge. Its first application delivered calibrated thermal images as a function of turbine rotational speed at both steady state conditions and during engine transients. In advance of presenting these data for the purpose of understanding engine operation, this paper focuses on the components of the system, verification of high-speed synchronized operation, and the integration of the system with the commercial jet engine test bed.
    Print ISSN: 0034-6748
    Electronic ISSN: 1089-7623
    Topics: Electrical Engineering, Measurement and Control Technology , Physics
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 48
    Publication Date: 2014-12-06
    Description: We present a home built electrochemical scanning tunneling microscope (ECSTM) with very high stability and repeatability. Its coarse approach is driven by a closely stacked piezo motor of GeckoDrive type with four rigid clamping points, which enhances the rigidity, compactness, and stability greatly. It can give high clarity atomic resolution images without sound and vibration isolations. Its drifting rates in XY and Z directions in solution are as low as 84 pm/min and 59 pm/min, respectively. In addition, repeatable coarse approaches in solution within 2 mm travel distance show a lateral deviation less than 50 nm. The gas environment can be well controlled to lower the evaporation rate of the cell, thus reducing the contamination and elongating the measurement time. Atomically resolved SO 4 2− image on Au (111) work electrode is demonstrated to show the performance of the ECSTM.
    Print ISSN: 0034-6748
    Electronic ISSN: 1089-7623
    Topics: Electrical Engineering, Measurement and Control Technology , Physics
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 49
    Publication Date: 2014-12-02
    Description: Electrospray mass spectrometry is now a widely used technique for observing cell content of various biological tissues. However, electrospray techniques (liquid chromatography and direct infusion) often involve lysing a group of cells and extracting the biomolecules of interest, rather than a sensitive, individual cell method to observe local chemistry. Presented here is an approach of combining a nanomanipulator workstation with nanospray mass spectrometry, which allows for extraction of a single cell, followed by rapid mass analysis that can provide a detailed metabolic profile. Triacylglycerol content was profiled with this tool coupled to mass spectrometry to investigate heterogeneity between healthy and tumorous tissues as well as lipid droplet containing adipocytes in vitro as proof of concept. This selective approach provides cellular resolution and complements existing bioanalytical techniques with minimal invasion to samples. In addition, the coupling of nanomanipulation and mass spectrometry holds the potential to be used in a great number of applications for individual organelles, diseased tissues, and in vitro cell cultures for observing heterogeneity even amongst cells and organelles of the same tissue.
    Print ISSN: 0034-6748
    Electronic ISSN: 1089-7623
    Topics: Electrical Engineering, Measurement and Control Technology , Physics
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 50
    Publication Date: 2014-12-03
    Description: We present a space and time resolved interferometric plasma diagnostic for use on plasmas where neutral-bound electron contribution to the refractive index cannot be neglected. By recording simultaneously the plasma optical index at 532 and 1064 n m , we are able to extract independently the neutral and free electron density profiles. We report a phase resolution of 30 m rad , corresponding to a maximum resolution on the order of 4 × 10 22 m − 3 for the electron density, and of 10 24 m − 3 for the neutral density. The interferometer is demonstrated on centimeter-scale sparks triggered by laser filamentation in air with typical currents of a few tens of A.
    Print ISSN: 0034-6748
    Electronic ISSN: 1089-7623
    Topics: Electrical Engineering, Measurement and Control Technology , Physics
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 51
    Publication Date: 2014-12-04
    Description: An ultrasonic contact-type position restoration mechanism is proposed and investigated in this paper. In the mechanism, two driving points of an ultrasonic vibrator, excited by an AC voltage, produces a restoring force on a slider so that the slider can be pushed back to its equilibrium after it is perturbed away from its equilibrium. The restoring force is generated by the unbalance of ultrasonic frictional driving forces on the slider, which is caused by a pressure difference on the two driving points. A prototype of this mechanism is fabricated, and the effects of the driving voltage, preload between the slider and vibrator, and slider's size on the restoring characteristics are experimentally measured and analyzed.
    Print ISSN: 0034-6748
    Electronic ISSN: 1089-7623
    Topics: Electrical Engineering, Measurement and Control Technology , Physics
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 52
    Publication Date: 2014-12-05
    Description: In a subduction system the force and the energy required to deform the overriding plate are generally thought to come from the negative buoyancy of the subducted slab and its potential energy, respectively. Such deformation might involve extension and backarc basin formation, or shortening and mountain building. How much of the slab's potential energy is consumed during overriding plate deformation remains unknown. In this work, we present dynamic three-dimensional laboratory experiments of progressive subduction with an overriding plate to quantify the force ( F OPD ) that drives overriding plate deformation and the associated energy dissipation rate (Φ OPD ), and we compare them with the negative buoyancy ( F BU ) of the subducted slab and its total potential energy release rate (Φ BU ), respectively. We varied the viscosity ratio between the plates and the sub-lithospheric upper mantle with η SP /η UM  = 157-560, and the thickness of the overriding plate with T OP  = 0.5-2.5 cm (scaling to 25-125 km in nature). The results show that F OPD / F BU has average values of 0.5-2.0%, with a maximum of 5.3% and Φ OPD /Φ BU has average values of 0.05-0.30%, with a maximum of 0.41%. The results indicate that only a small portion of the negative buoyancy of the slab and its potential energy are used to deform the overriding plate. Our models also suggest that the force required to deform the overriding plate is of comparable magnitude to the ridge push force. Furthermore, we show that in subduction models with an overriding plate bending dissipation at the subduction zone hinge remains low (3-15% during steady-state subduction).
    Print ISSN: 0148-0227
    Topics: Geosciences , Physics
    Published by Wiley on behalf of American Geophysical Union (AGU).
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 53
    Publication Date: 2014-12-05
    Description: We investigated the influence of earthquake source complexity on the extent of inundation caused by the resulting tsunami. We simulated 100 scenarios with collocated sources of variable slip on the Hikurangi subduction-interface in the vicinity of Hawke's Bay and Poverty Bay in New Zealand and investigated the tsunami effects on the cities of Napier and Gisborne. Rupture complexity was found to have a first order effect on flow depth and inundation extent for local tsunami sources. The position of individual asperities in the slip distribution on the rupture interface control to some extent how severe inundation will be. However, predicting inundation extent in detail from investigating the distribution of slip on the rupture interface proves difficult. Assuming uniform slip on the rupture interface in tsunami models can underestimate the potential impact and extent of inundation. For example, simulation of an M W 8.7 to M W 8.8 earthquake with uniform slip reproduced the area that could potentially be inundated by equivalent non-uniform slip events of M W 8.4. De-aggregation, to establish the contribution of different sources with different slip distributions to the probabilistic hazard, cannot be performed based on magnitude considerations alone. We propose two predictors for inundation severity based on the offshore tsunami wave field using the linear wave equations in an attempt to keep costly simulations of full inundation to a minimum.
    Print ISSN: 0148-0227
    Topics: Geosciences , Physics
    Published by Wiley on behalf of American Geophysical Union (AGU).
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 54
    Publication Date: 2014-12-05
    Description: Teleseismic transfer function analysis is used to investigate crust and upper mantle velocity structure in the vicinity of the active eastern Tennessee seismic zone (ETSZ). The ETSZ is associated with the New York – Alabama (NY-AL) magnetic lineament, a prominent aeromagnetic anomaly indicative of Grenville-age, basement structure. Radial component, P-wave transfer functions for ten short-period stations operated by the Center for Earthquake Research and Information (CERI) are inverted for velocity structure. Velocity profiles are also determined for three broadband stations by converting the instrument response to that of an S-13 short-period seismometer. Distinct differences in the velocity profiles are found for stations located on either side of the NY-AL magnetic lineament; velocities west of the lineament are lower than velocities to the east of the lineament in the upper 10 km and in the depth range 30 to 50 km. A gradational Moho boundary is found beneath several stations located in the Valley and Ridge province. A Moho boundary is absent at four Valley and Ridge stations located east of the magnetic lineament and south of 35.5°N.
    Print ISSN: 0148-0227
    Topics: Geosciences , Physics
    Published by Wiley on behalf of American Geophysical Union (AGU).
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 55
    Publication Date: 2014-12-05
    Description: This integrated study provides significant insight into parameters controlling the acoustic and reservoir properties of microporous limestones, improving the knowledge of the relationships among petrophysic and microstructural content. Petrophysical properties measured from laboratory and logging tools (porosity, permeability, electrical conductivity and acoustic properties) have been coupled with thin section and SEM observations on the EST205 borehole from the Oxfordian limestone aquifer of the Eastern part of the Paris Basin. A major achievement is the establishment of the link between micrite microtexture types (particle morphology and nature of inter-crystal contacts) and the physical response, introducing a new effective and interesting rock-typing approach for microporous reservoirs. Fluid-flow properties are enhanced by the progressive augmentation of intercrystalline microporosity and associated pore throat diameter, as the coalescence of micrite particles decreases. Concerning acoustic properties, the slow increase of P-wave velocity can be seen as a reflection of crystal size and growing contact cementation leading to a more cohesive and stiffer micrite microtexture. By applying poroelasticity theory on our samples, we show that velocity dispersion can be a very useful tool for data discrimination in carbonates. This dispersion analysis highlights the presence of microcracks in the rocks, and their overall effect on acoustic and transport properties. The presence of microcracks is also confirmed with observations and permeability measurements under high confining pressure. Finally, a possible origin of high porous levels in neritic limestones is a mineralogical transformation of carbonates through freshwater-related diagenesis during subaerial exposure time. Finally, by applying poroelasticity theory on our samples, we show that velocity dispersion can be a very useful tool for data discrimination in carbonates.
    Print ISSN: 0148-0227
    Topics: Geosciences , Physics
    Published by Wiley on behalf of American Geophysical Union (AGU).
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 56
    Publication Date: 2014-12-05
    Description: The “local porosity theory” proposed by Hilfer was revisited to develop a “local clay theory” (LCT) that establishes a quantitative relationship between the effective electrical conductivity and clay distribution in clay-rocks. This theory is primarily based on a “local simplicity” assumption; under this assumption, the complexity of spatial clay distribution can be captured by two local functions, namely, the local clay distribution and the local percolation probability, which are calculated from a partitioning of a mineral map. The local clay distribution provides information about spatial clay fluctuations and the local percolation probability describes the spatial fluctuations in the clay connectivity. This LCT was applied to (a) a mineral map made from a Callovo-Oxfordian mudstone sample and (b) (macroscopic) electrical conductivity measurements performed on the same sample. The direct and inverse modeling show two results. First, the textural and classical model assuming that the electrical anisotropy of clay-rock is mainly controlled by the anisotropy of the sole clay matrix provides inconsistent inverted values. An other textural effect, the anisotropy induced by elongated and oriented non-clayey grains, should be considered. Second, the effective conductivity values depend primarily on the choice of the inclusion-based models used in the LCT. The impact of local fluctuations of clay content and connectivity on the calculated effective conductivity is lower.
    Print ISSN: 0148-0227
    Topics: Geosciences , Physics
    Published by Wiley on behalf of American Geophysical Union (AGU).
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 57
    Publication Date: 2014-12-05
    Description: Volcanic ash is often deposited in a hot state. Volcanic ash containing glass, deposited above the glass transition interval, has the potential to sinter viscously both to itself (particle-particle) and to exposed surfaces. Here, we constrain the kinetics of this process experimentally under non-isothermal conditions using standard glasses. In the absence of external load, this process is dominantly driven by surface relaxation. In such cases the sintering process is rate-limited by the melt viscosity, the size of the particles and the melt-vapour interfacial tension. We propose a polydisperse continuum model that describes the transition from a packing of particles to a dense pore-free melt and evaluate its efficacy in describing the kinetics of volcanic viscous sintering. We apply our model to viscous sintering scenarios for cooling crystal-poor rhyolitic ash using the 2008 eruption of Chaitén volcano as a case example. We predict that moderate linear cooling rates of 〉10 -1  °C.min -1 can result in the common observation of incomplete sintering and the preservation of pore networks.
    Print ISSN: 0148-0227
    Topics: Geosciences , Physics
    Published by Wiley on behalf of American Geophysical Union (AGU).
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 58
    Publication Date: 2014-01-11
    Description: A transverse beam emittance and acceptance measurement system has been developed to visualize the relationship between the injected beam emittance and the acceptance of a cyclotron. The system is composed of a steering magnet, two pairs of slits to limit the horizontal and vertical phase-space, a beam intensity detector just behind the slits for the emittance measurement, and a beam intensity detector in the cyclotron for the acceptance measurement. The emittance is obtained by scanning the slits and measuring the beam intensity distribution. The acceptance is obtained by measuring the distribution of relative beam transmission by injecting small emittance beams at various positions in a transverse phase-space using the slits. In the acceptance measurement, the beam from an ion source is deflected to the defined region by the slits using the steering magnet so that measurable acceptance area covers a region outside the injection beam emittance. Measurement tests were carried out under the condition of accelerating a beam of 16 O 6+ from 50.2 keV to 160 MeV. The emittance of the injected beam and the acceptance for accelerating and transporting the beam to the entrance of the extraction deflector were successfully measured. The relationship between the emittance and acceptance is visualized by displaying the results in the same phase-plane.
    Print ISSN: 0034-6748
    Electronic ISSN: 1089-7623
    Topics: Electrical Engineering, Measurement and Control Technology , Physics
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 59
    facet.materialart.
    Unknown
    American Institute of Physics (AIP)
    Publication Date: 2014-01-11
    Description: In the development of magnetically confined fusion as an economically sustainable power source, International Tokamak Experimental Reactor (ITER) is currently under construction. Beyond ITER is the demonstration fusion reactor (DEMO) programme in which the physics and engineering aspects of a future fusion power plant will be demonstrated. DEMO will produce net electrical power. The DEMO programme will be outlined and the role of neutral beams for heating and current drive will be described. In particular, the importance of the efficiency of neutral beam systems in terms of injected neutral beam power compared to wallplug power will be discussed. Options for improving this efficiency including advanced neutralisers and energy recovery are discussed.
    Print ISSN: 0034-6748
    Electronic ISSN: 1089-7623
    Topics: Electrical Engineering, Measurement and Control Technology , Physics
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 60
    Publication Date: 2014-01-11
    Description: Extracted ion beams from the test laser ion source (LIS) were transported through a test beam transport line which is almost identical to the actual primary beam transport in the current electron beam ion source apparatus. The tested species were C, Al, Si, Cr, Fe, Cu, Ag, Ta, and Au. The all measured beam currents fulfilled the requirements. However, in the case of light mass ions, the recorded emittance shapes have larger aberrations and the RMS values are higher than 0.06 π mm mrad, which is the design goal. Since we have margin to enhance the beam current, if we then allow some beam losses at the injection point, the number of the single charged ions within the acceptance can be supplied. For heaver ions like Ag, Ta, and Au, the LIS showed very good performance.
    Print ISSN: 0034-6748
    Electronic ISSN: 1089-7623
    Topics: Electrical Engineering, Measurement and Control Technology , Physics
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 61
    facet.materialart.
    Unknown
    American Institute of Physics (AIP)
    Publication Date: 2014-01-11
    Description: A tunable transmission grating was fabricated by molding a silicone elastomer (polydimethylsiloxane). Its optical characteristics were then evaluated during compression. For fabrication, a glass plate with a photoimprinted polymer grating film was used as a mold. Both the grating period and diffraction transmittance of the molded elastomer were functions of the compressive stress. The grating period changed from 3.02 to 2.86 μ m during compressing the elastomer in the direction perpendicular to the grooves.
    Print ISSN: 0034-6748
    Electronic ISSN: 1089-7623
    Topics: Electrical Engineering, Measurement and Control Technology , Physics
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 62
    Publication Date: 2014-01-15
    Description: [1]  We analyse 1980-2010 ground displacements, to discern similarities or differences between Campi Flegrei (CF) inflations and deflations and highlight possible anomalies in particular areas. We show that the deformation pattern can be decomposed into two stationary (constant over time, except for a mere scaling factor) parts; both of them are satisfied by simple deformation sources. A quasi-horizontal elongated crack (oriented NW to SE, and embedded in an elastic layered half-space at a depth of about 3600 m) satisfies large-scale deformation. All source parameters but potency (volume change) are constant over time. Residual deformation is confined to the area of the Solfatara fumarolic field and satisfied by a small spheroid located at about 1900 m in depth. Again, all source parameters but potency are constant over time. The histories of the two sources are somewhat similar but not equal, supporting the existence of a genuine local deformation source at Solfatara against the emergence of a mere distortion of large-scale deformation. Although reality is probably much more complex, our simple model explains 1980-2010 CF deformation within ground-displacement data errors, and is consistent with Solfatara geochemical conceptual models, fumarolic geochemical data, and seismic attenuation imaging of CF. The observation that the CF deformation pattern can be decomposed into two stationary parts is hardly compatible with several recent works which proposed multiple sources with different features acting in different periods, fluid injections implying ample changes of large-scale deformation pattern over time, complex spatial and temporal patterns of distributions of volumetric sources.
    Print ISSN: 0148-0227
    Topics: Geosciences , Physics
    Published by Wiley on behalf of American Geophysical Union (AGU).
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 63
    facet.materialart.
    Unknown
    American Institute of Physics (AIP)
    Publication Date: 2014-01-15
    Description: Ion sources for ion implantation are introduced. The technique is applied not only to large scale integration (LSI) devices but also to flat panel display. For LSI fabrication, ion source scheduled maintenance cycle is most important. For CMOS image sensor devices, metal contamination at implanted wafer is most important. On the other hand, to fabricate miniaturized devices, cluster ion implantation has been proposed to make shallow PN junction. While for power devices such as silicon carbide, aluminum ion is required. For doping processes of LCD fabrication, a large ion source is required. The extraction area is about 150 cm × 10 cm, and the beam uniformity is important as well as the total target beam current.
    Print ISSN: 0034-6748
    Electronic ISSN: 1089-7623
    Topics: Electrical Engineering, Measurement and Control Technology , Physics
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 64
    Publication Date: 2014-01-15
    Description: In order to carry out precise laboratory measurements of infrared absorption intensities, line profiles of molecules and organic volatile compounds for atmospheric chemistry in planetary and upper earth atmospheric layers, precise gas pressure measurement between 10 −3 and a few mbars in the 77–300 K temperature range is necessary. A prototype, rugged, precision capacitive pressure gauge for cryogenic use has been designed, built at SOLEIL and tested down to 77 K. The design includes corrosion-resistant materials and has been tailored to operate on a differential measurement scheme based on a simple, precision capacitance-to-digital converter chip, instead of high precision floating capacitive bridges, as are used in other designs. The designs conception and performance specifications are presented here, illustrated by a precision of better than 1% in the 0.2–40 mbar range, with a resolution of 2 × 10 −3 mbar. The gauge is tunable and can be adjusted for higher precision and a better resolution, at the expense of the maximum high-pressure range.
    Print ISSN: 0034-6748
    Electronic ISSN: 1089-7623
    Topics: Electrical Engineering, Measurement and Control Technology , Physics
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 65
    Publication Date: 2014-01-16
    Description: A novel method for predictions of the sound pressure distribution in acoustic levitators is based on a matrix representation of the Rayleigh integral. This method allows for a fast calculation of the acoustic field within the resonator. To make sure that the underlying assumptions and simplifications are justified, this approach was tested by a direct comparison to experimental data. The experimental sound pressure distributions were recorded by high spatially resolved frequency selective microphone scanning. To emphasize the general applicability of the two approaches, the comparative studies were conducted for four different resonator geometries. In all cases, the results show an excellent agreement, demonstrating the accuracy of the matrix method.
    Print ISSN: 0034-6748
    Electronic ISSN: 1089-7623
    Topics: Electrical Engineering, Measurement and Control Technology , Physics
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 66
    Publication Date: 2014-01-16
    Description: Vibrating mechanical structure characterization is demonstrated using contactless techniques best suited for mobile and rotating equipments. Fast measurement rates are achieved using Field Programmable Gate Array (FPGA) devices as real-time digital signal processors. Two kinds of algorithms are implemented on FPGA and experimentally validated in the case of the vibrating tuning fork. A first application concerns in-plane displacement detection by vision with sampling rates above 10 kHz, thus reaching frequency ranges above the audio range. A second demonstration concerns pulsed-RADAR cooperative target phase detection and is applied to radiofrequency acoustic transducers used as passive wireless strain gauges. In this case, the 250 ksamples/s refresh rate achieved is only limited by the acoustic sensor design but not by the detection bandwidth. These realizations illustrate the efficiency, interest, and potentialities of FPGA-based real-time digital signal processing for the contactless interrogation of passive embedded probes with high refresh rates.
    Print ISSN: 0034-6748
    Electronic ISSN: 1089-7623
    Topics: Electrical Engineering, Measurement and Control Technology , Physics
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 67
    Publication Date: 2014-01-16
    Description: Organic devices have to be protected with a permeation barrier against ambient moisture since their performance is strongly reduced by contact with water. The corrosion of calcium is widely used to evaluate such permeation barriers. However, design details of the calcium corrosion test may have severe consequences for the validity and precision of the measurement results. In this work, we present such a measurement distortion caused by the direct contact between calcium and the inorganic permeation barrier. Fortunately, even a 20 nm thin interlayer of a soft material (i.e., C 60 ) sandwiched between calcium and the barrier reestablishes the validity of the measurement. In addition, we present our latest and improved electrical calcium test layout used for this investigation.
    Print ISSN: 0034-6748
    Electronic ISSN: 1089-7623
    Topics: Electrical Engineering, Measurement and Control Technology , Physics
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 68
    facet.materialart.
    Unknown
    American Institute of Physics (AIP)
    Publication Date: 2014-01-16
    Description: We present a precision, 1-A, digitally interfaced current controller for quantum cascade lasers, with demonstrated temperature coefficients for continuous and 40-kHz full-depth square-wave modulated operation, of 1–2 ppm/ °C and 15 ppm/ °C, respectively. High precision digital to analog converters (DACs) together with an ultra-precision voltage reference produce highly stable, precision voltages, which are selected by a multiplexer (MUX) chip to set output currents via a linear current regulator. The controller is operated in conjunction with a power multiplexing unit, allowing one of three lasers to be driven by the controller, while ensuring protection of controller and all lasers during operation, standby, and switching. Simple ASCII commands sent over a USB connection to a microprocessor located in the current controller operate both the controller (via the DACs and MUX chip) and the power multiplexer.
    Print ISSN: 0034-6748
    Electronic ISSN: 1089-7623
    Topics: Electrical Engineering, Measurement and Control Technology , Physics
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 69
    Publication Date: 2014-01-16
    Description: A 22 m diameter circular rail, outfitted with a mobile sonar tower trolley, was designed, fabricated, instrumented with underwater acoustic transducers, and assembled on a 1.5 m thick sand layer at the bottom of a large freshwater pool to carry out sonar design and target scattering response studies. The mobile sonar tower translates along the rail via a drive motor controlled by customized LabVIEW software. The rail system is modular and assembly consists of separately deploying eight circular arc sections, measuring a nominal center radius of 11 m and 8.64 m arc length each, and having divers connect them together in the underwater environment. The system enables full scale measurements on targets of interest with 0.1° angular resolution over a complete 360° aperture, without disrupting target setup, and affording a level of control over target environment conditions and noise sources unachievable in standard field measurements. In recent use, the mobile cart carrying an instrumented sonar tower was translated along the rail in 720 equal position increments and acoustic backscatter data were acquired at each position. In addition, this system can accommodate both broadband monostatic and bistatic scattering measurements on targets of interest, allowing capture of target signature phenomena under diverse configurations to address current scientific and technical issues encountered in mine countermeasure and unexploded ordnance applications. In the work discussed here, the circular rail apparatus is used for acoustic backscatter testing, but this system also has the capacity to facilitate the acquisition of magnetic and optical sensor data from targets of interest. A brief description of the system design and operation will be presented along with preliminary processed results for data acquired from acoustic measurements conducted at the Naval Surface Warfare Center, Panama City Division Test Pond Facility. [Work Supported by the U.S. Office of Naval Research and The Strategic Environmental Research and Development Program.]
    Print ISSN: 0034-6748
    Electronic ISSN: 1089-7623
    Topics: Electrical Engineering, Measurement and Control Technology , Physics
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 70
    Publication Date: 2014-01-16
    Description: Optical hydrophones are optimized pressure-pulse-sensors used for high-power shockwave sources, such as lithotripters. Recent investigation of Smith et al. [“A Comparison of light spot hydrophone and fiber optic probe hydrophone for lithotripter field characterization,” Rev. Sci. Instrum.83, 014301 (2012)] show discrepancies in the negative pressure peak and tensile pulse duration regarding measurements carried out with two optical hydrophones: the Light Spot Hydrophone (LSHD) and the fiber optic hydro-phone. It was assumed that the differences arise from cavitation effects at the end-face of the LSHD glass-block and filter characteristics of the trans-impedance amplifier of the LSHD. The present study investigates the transfer-function of the LSHD. It is shown that the filter characteristics of the amplifier cause discrepancies in the rarefaction pressure pulse fraction (depending on the energy settings of the source 15 ± 2%).
    Print ISSN: 0034-6748
    Electronic ISSN: 1089-7623
    Topics: Electrical Engineering, Measurement and Control Technology , Physics
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 71
    facet.materialart.
    Unknown
    American Institute of Physics (AIP)
    Publication Date: 2014-01-16
    Description: The fixed target experiment NA61 in the North Area of the Super Proton Synchrotron is studying phase transitions in strongly interacting matter. Up to now they used the primary beams available from the CERN accelerator complex (protons and lead ions) or fragmented beams created from the primary lead ion beam. To explore a wider range of energies and densities a request was made to provide primary argon and xenon beams. This paper describes the results of the setting up and 10 week test run of the Ar 11+ beam from the 14.5 GHz ECR ion source and the linear accelerator (Linac3) at CERN.
    Print ISSN: 0034-6748
    Electronic ISSN: 1089-7623
    Topics: Electrical Engineering, Measurement and Control Technology , Physics
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 72
    Publication Date: 2014-01-16
    Description: The new international accelerator facility for antiproton and ion research (FAIR) at GSI in Darmstadt, Germany, is one of the largest research projects worldwide and will provide an antiproton production rate of 7 × 10 10 cooled pbars per hour. This is equivalent to a primary proton beam current of 2 × 10 16 protons per hour. For this request a high intensity proton linac (p-linac) will be built with an operating rf-frequency of 325 MHz to accelerate a 35 mA proton beam at 70 MeV, using conducting crossed-bar H-cavities. The repetition rate is 4 Hz with beam pulse length of 36 μ s. The microwave ion source and low energy beam transport developed within a joint French-German collaboration GSI/CEA-SACLAY will serve as an injector of the compact proton linac. The 2.45 GHz ion source allows high brightness ion beams at an energy of 95 keV and will deliver a proton beam current of 100 mA at the entrance of the radio frequency quadrupole (RFQ) within an acceptance of 0.3π mm mrad (norm., rms).
    Print ISSN: 0034-6748
    Electronic ISSN: 1089-7623
    Topics: Electrical Engineering, Measurement and Control Technology , Physics
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 73
    Publication Date: 2014-01-16
    Description: We present a novel ultra-high resolution Raman spectroscopy technique based in a Fabry-Pérot/triple spectrometer tandem with multichannel acquisition. We describe the system, detail the calibration process, and experimentally test the technique, showing that effective finesses in excess of 1000 are possible. The technique is specifically tailored for low intensity, complex and spectrally extended Raman spectra, providing shorter acquisition times with respect to similar tandem systems with monochannel detectors.
    Print ISSN: 0034-6748
    Electronic ISSN: 1089-7623
    Topics: Electrical Engineering, Measurement and Control Technology , Physics
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 74
    Publication Date: 2014-01-16
    Description: The plasma electrode structure of a 14 GHz ECR ion source was modified to enlarge the plasma volume of low electron temperature region. The result shows that the extracted beam current reached about 0.6 mA/cm 2 with about 40 W microwave power. To investigate the correlation between the volume of the low electron temperature region and the H − current, a vacuum ultraviolet (VUV) spectrometer had been installed to observe light emission in the VUV wavelength range from the plasma. From the results of the negative ion beam current and that from VUV spectrometry, production rate of vibrationally excited hydrogen molecule seems to be enhanced by increasing the volume of low electron temperature region.
    Print ISSN: 0034-6748
    Electronic ISSN: 1089-7623
    Topics: Electrical Engineering, Measurement and Control Technology , Physics
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 75
    facet.materialart.
    Unknown
    American Institute of Physics (AIP)
    Publication Date: 2014-01-16
    Description: Progress in the kinetic modeling of particle dynamics in H − negative ion source plasmas and their comparisons with experiments are reviewed, and discussed with some new results. Main focus is placed on the following two topics, which are important for the research and development of large negative ion sources and high power H − ion beams: (i) Effects of non-equilibrium features of EEDF (electron energy distribution function) on H − production, and (ii) extraction physics of H − ions and beam optics.
    Print ISSN: 0034-6748
    Electronic ISSN: 1089-7623
    Topics: Electrical Engineering, Measurement and Control Technology , Physics
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 76
    Publication Date: 2014-01-16
    Description: Over the past two years, we have tried to improve the performance of the RIKEN superconducting electron cyclotron resonance ion source using several methods. For the production of U vapor, we chose the sputtering method because it is possible to install a large amount of material inside the plasma chamber and thus achieve long-term operation without a break, although it is assumed that the beam intensity is weaker than in the oven technique. We also used an aluminum chamber instead of a stainless steel one. Using these methods, we successfully produced ∼180 eμA of U 35+ and ∼230 eμA of U 33+ at the injected radio frequency (RF) power of ∼4 kW (28 GHz). Very recently, to further increase the beam intensity of U 35+ , we have started to develop a high temperature oven and have successfully produced a highly charged U ion beam. In this contribution, we report on the beam intensity of highly charged U ions as a function of various parameters (RF power and sputtering voltage) and discuss the effects of these parameters on the beam stability in detail.
    Print ISSN: 0034-6748
    Electronic ISSN: 1089-7623
    Topics: Electrical Engineering, Measurement and Control Technology , Physics
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 77
    Publication Date: 2014-01-16
    Description: Our previous study by two dimension in real space and three dimension in velocity space-particle in cell model shows that the curvature of the plasma meniscus causes the beam halo in the negative ion sources. The negative ions extracted from the periphery of the meniscus are over-focused in the extractor due to the electrostatic lens effect, and consequently become the beam halo. The purpose of this study is to verify this mechanism with the full 3D model. It is shown that the above mechanism is essentially unchanged even in the 3D model, while the fraction of the beam halo is significantly reduced to 6%. This value reasonably agrees with the experimental result.
    Print ISSN: 0034-6748
    Electronic ISSN: 1089-7623
    Topics: Electrical Engineering, Measurement and Control Technology , Physics
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 78
    Publication Date: 2014-01-17
    Description: [1]  Detailed three-dimensional (3-D) P - and S -wave attenuation ( Qp and Qs ) models of the crust and upper mantle under the entire Northeast Japan (Tohoku) arc from the Japan Trench to the Japan Sea coast are determined, for the first time, using a large number of high-quality t * data measured precisely from P - and S -wave spectra of local earthquakes. The suboceanic earthquakes used in this work are relocated precisely using sP depth phases. Our results reveal a prominent landward dipping high- Q zone representing the subducting Pacific slab, a landward dipping intermediate to high Q zone in the mantle wedge between the Pacific coast and the volcanic front, and significant low- Q anomalies in the crust and mantle wedge between the volcanic front and the Japan Sea coast. Prominent high- Q patches surrounded by low- Q anomalies are revealed in the interplate megathrust zone under the Tohoku forearc where the great 2011 Tohoku-oki earthquake ( Mw 9.0) occurred. The high- Q patches in the megathrust zone generally exhibit large coseismic slips of megathrust earthquakes and large slip deficit on the plate interface. We think that these high- Q patches represent asperities in the megathrust zone, whereas the low- Q anomalies reflect weakly coupled areas. We also find that the hypocenters of the 2011 Tohoku-oki earthquake and its large foreshock ( Mw 7.3) and two large megathrust aftershocks ( Mw 7.4, 7.7) are located in areas where Qp , Qs and Qp / Qs change abruptly. These results suggest that structural heterogeneities in the megathrust zone control the interplate seismic coupling and the nucleation of megathrust earthquakes.
    Print ISSN: 0148-0227
    Topics: Geosciences , Physics
    Published by Wiley on behalf of American Geophysical Union (AGU).
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 79
    facet.materialart.
    Unknown
    American Institute of Physics (AIP)
    Publication Date: 2014-01-17
    Description: The paper describes the principle of operation, design special features, and parameters of an inverted time-of-flight spectrometer. The spectrometer is designed in such way that its deflecting plates, drift tube, and primary measuring system are at high potential with respect to the ground potential, whereas plasma is formed near grounded electrodes. This type of configuration greatly extends the application range of the device, making it possible to measure the mass-to-charge composition of plasma with wide range of parameters.
    Print ISSN: 0034-6748
    Electronic ISSN: 1089-7623
    Topics: Electrical Engineering, Measurement and Control Technology , Physics
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 80
    facet.materialart.
    Unknown
    American Institute of Physics (AIP)
    Publication Date: 2014-01-17
    Description: A 70 mm diameter 70 mm long compact ion source equipped with a hollow sputtering target has been designed and tested. The hollow sputtering target serves as the radio frequency (RF) plasma excitation electrode at 13.56 MHz. A stable beam of Cu + has been extracted when Ar was used as the discharge support gas. In the extracted beam, Cu + had occupied more than 85% of the total ion current. Further increase in Cu + ions in the beam is anticipated by increasing the RF power and Ar pressure.
    Print ISSN: 0034-6748
    Electronic ISSN: 1089-7623
    Topics: Electrical Engineering, Measurement and Control Technology , Physics
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 81
    Publication Date: 2014-01-17
    Description: In this paper we present our cyclotron based neutron source with average energy 6.3 MeV generated during the 13.6 MeV deuterons interactions with beryllium target, neutron field dosimetry, and dosimetry of attendant gamma fields. We also present application of our neutron source for cancer treatment.
    Print ISSN: 0034-6748
    Electronic ISSN: 1089-7623
    Topics: Electrical Engineering, Measurement and Control Technology , Physics
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 82
    Publication Date: 2014-01-18
    Description: Grating-based X-ray and neutron interferometry tomography using phase-stepping methods generates large data sets. An improved algorithm is presented for solving for the parameters to calculate transmissions, differential phase contrast, and dark-field images. The method takes advantage of the vectorization inherent in high-level languages such as Mathematica and MATLAB and can solve a 16 × 1 k × 1 k data set in less than a second. In addition, the algorithm can function with partial data sets. This is demonstrated with processing of a 16-step grating data set with partial use of the original data chosen without any restriction. Also, we have calculated the reduced chi-square for the fit and notice the effect of grating support structural elements upon the differential phase contrast image and have explored expanded basis set representations to mitigate the impact.
    Print ISSN: 0034-6748
    Electronic ISSN: 1089-7623
    Topics: Electrical Engineering, Measurement and Control Technology , Physics
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 83
    Publication Date: 2014-01-18
    Description: The prototype rf-driven H − ion-source with a nickel plated oxygen-free-copper (OFC) plasma chamber, which satisfies the Japan Proton Accelerator Research Complex (J-PARC) 2nd stage requirements of a H − ion beam current of 60 mA within normalized emittances of 1.5 π mm mrad both horizontally and vertically, a flat top beam duty factor of 1.25% (500 μ s × 25 Hz) and a life-time of more than 50 days, was reported at the 3rd international symposium on negative ions, beams, and sources (NIBS2012). The experimental results of the J-PARC ion source with a plasma chamber made of stainless-steel, instead of nickel plated OFC used in the prototype source, are presented in this paper. By comparing these two sources, the following two important results were acquired. One was that the about 20% lower emittance was produced by the rather low plasma electrode (PE) temperature (T PE ) of about 120 °C compared with the typically used T PE of about 200 °C to maximize the beam current for the plasma with the abundant cesium (Cs). The other was that by using the rod-filter magnets with a gap at each center and tuning the gap-lengths, the filter-field was optimized and the rf-power necessary to produce the J-PARC required H − ion beam current was reduced typically 18%. The lower rf-power also decreases the emittances.
    Print ISSN: 0034-6748
    Electronic ISSN: 1089-7623
    Topics: Electrical Engineering, Measurement and Control Technology , Physics
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 84
    Publication Date: 2014-01-18
    Description: In this paper we describe the first systematic measurement of beam neutralization (space charge compensation) in the ECR low energy transport line with a retarding field analyzer, which can be used to measure the potential of the beam. Expected trends for the space charge compensation levels such as increase with residual gas pressure, beam current, and beam density could be observed. However, the overall levels of neutralization are consistently low (
    Print ISSN: 0034-6748
    Electronic ISSN: 1089-7623
    Topics: Electrical Engineering, Measurement and Control Technology , Physics
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 85
    Publication Date: 2014-01-22
    Description: This study aims at the design and development of electromagnetic-type intermittent shock wave generation in a liquid. The shock wave generated is focused at a focal point through an acoustic lens. This hardware device mainly consists of a full-wave bridge rectifier, 6 capacitors, a spark gap, and a flat coil. A metal disk is mounted in a liquid-filled tube and is placed in close proximity to the flat coil. Due to the repulsive force existing between the coil and disk shock waves are generated, while an eddy current is induced in the metal disk. Some components and materials associated with the device are also described. By increasing the capacitance content to enhance electric energy level, a highly focused pressure can be achieved at the focal point through an acoustic lens in order to lyse fat tissue. Focused pressures were measured at the focal point and its vicinity for different operation voltages. The designed shock wave generator with an energy intensity of 0.0016 mJ/mm 2 (at 4 kV) and 2000 firings or higher energy intensities with 1000 firings is found to be able to disrupt pig fat tissue.
    Print ISSN: 0034-6748
    Electronic ISSN: 1089-7623
    Topics: Electrical Engineering, Measurement and Control Technology , Physics
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 86
    Publication Date: 2014-01-24
    Description: [1]  We detected 32,078 very small, local microearthquakes (average M L  = -1) during a 9-month deployment of five ocean bottom seismometers (OBS) on the periphery of the Trans-Atlantic Geotraverse (TAG) active mound. Seismicity rates were constant without any mainshock-aftershock behavior at ~243 events per day at the beginning of the experiment, 128 events per day after an instrument failed, and 97 events per day at the end of the experiment when whale calls increased background noise levels. The microearthquake seismograms are characterized by durations of 〈1 second and most have single-phase P -wave arrivals (i.e., no S -arrivals). We accurately located 6,207 of the earthquakes, with hypocenters clustered within a narrow depth interval from ~50-125 mbsf on the south and west flanks of the deposit. We model the microearthquakes as reaction-driven fracturing events caused by anhydrite deposition in the secondary circulation system of the hydrothermal mound, and show that under reasonable modeling assumptions an average event represents a volume increase of 31-58 cm 3 , yielding an annual (seismogenic) anhydrite deposition rate of 27-51 m 3 .
    Print ISSN: 0148-0227
    Topics: Geosciences , Physics
    Published by Wiley on behalf of American Geophysical Union (AGU).
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 87
    Publication Date: 2014-01-11
    Description: [1]  Acoustic velocity measurements were conducted during triaxial deformation tests of silty clay and clayey silt core samples from the Nankai subduction zone (IODP Expeditions 315, 316 and 333). We provide a new set of sonic wave velocity data, continuously measured during pressure increase and subsequent axial deformation. A new processing method for the experimental data was developed using seismic time series analysis. The results show that the identification of first arrivals by manual trace-by-trace picking alone can be erroneous. During axial deformation compressional wave velocities (Vp) range between about 1300 - 2200 m/s, and shear wave velocities (Vs) range between about 150 - 800 m/s. Vp slightly increases with rising effective confining pressure and effective axial stress. Samples from the accretionary prism toe show the highest Vp, while those from the forearc slope sediments show somewhat lower Vp. The samples from the incoming plate are slightly richer in clay minerals, and have the lowest values for Vp. Vs increases with higher effective confining pressures and effective axial stress, irrespective of composition and tectonic setting. Shear and bulk moduli, calculated from sonic velocities are in the range between 0.2 and 1.3 GPa and 3.85 and 8.41 GPa, respectively. The elastic moduli of the samples from the accretionary prism toe and the footwall of the megasplay fault ranging between 1.50 and 3.98 GPa are higher compared to those from the hanging wall samples and the incoming plate samples ranging between 0.59 and 0.88 Gpa. Thus, they allow differentiation between normal and over-consolidated sediments. The data show that in a tectono-sedimentary environment of only subtle compositional differences, the acoustic properties can be used to differentiate between stronger (accretionary prism toe) and weaker (forearc slope, incoming plate) sediments. Especially the Vp/Vs ratio may be instrumental in detecting zones of low effective stress and thus high pore fluid pressure.
    Print ISSN: 0148-0227
    Topics: Geosciences , Physics
    Published by Wiley on behalf of American Geophysical Union (AGU).
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 88
    Publication Date: 2014-01-11
    Description: [1]  Studies of the petrology, mineral chemistry and rock-magnetic properties of nine pyroxenite xenoliths from Hannuoba basalts, northern North China Craton, have been made to determine the magnetization signature of the continental lower crust. These pyroxenites are weakly magnetic with low average susceptibility ( χ ) and saturation isothermal remanent magnetization ( M rs ) of 39.59 × 10 -8  m 3  kg -1 and 12.05 × 10 -3 Am 2 kg -1 , respectively. The magnetic minerals are mainly magnetite, pyrrhotite and Fe-rich spinel, which significantly contribute to χ and natural remanent magnetization. Magnetite occurs as interstitial micro-crystals together with zeolite aggregates, indicating a secondary origin in a supergene environment. In contrast, pyrrhotite and Fe-rich spinel were formed prior to the xenoliths’ ascent to the surface, as evidenced by their dominant occurrence as tiny inclusions and thin exsolution lamellae in pyroxene. The Fe-rich spinel has ~ 50% mole-fraction of Fe 3 O 4 and corresponds to the strongest magnetization, and its coexistence with Mg-rich spinel implies a reheating event due to the underplating of basaltic magma. Besides, armalcolite and ilmenite were found in the reaction rims between xenoliths and the basalt, but they contribute little to the whole rock magnetization. However, these pyroxenite xenoliths would be non-magnetic at in situ depths, as well as peridotite and mafic granulite xenoliths derived from the crust-mantle transition zone (~ 32-42 km). Therefore, we suggest the limiting depth of magnetization at the boundary between weakly magnetic deep-seated (lower crust and upper mantle) xenoliths and strongly magnetic Archean granulite facies rocks (~ 32 km) in Hannuoba, northern North China Craton.
    Print ISSN: 0148-0227
    Topics: Geosciences , Physics
    Published by Wiley on behalf of American Geophysical Union (AGU).
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 89
    Publication Date: 2014-01-15
    Description: [1]  The shallow velocity structure of the Lucky Strike segment of the Mid-Atlantic Ridge is investigated using seismic refraction and reflection techniques applied to downward continued multi-channel streamer data. We present a three-dimensional velocity model beneath the Lucky Strike Volcano with unprecedented spatial resolutions of a few hundred meters. These new constraints reveal large lateral variations in P-wave velocity structure beneath this feature. Throughout the study area, uppermost crustal velocities are significantly lower than those inferred from lower-resolution OBS studies, with the lowest values (1.8-2.2 km/s) found beneath the three central volcanic cones. Within the central volcano, distinct shallow units are mapped that likely represent a systematic process such as burial of older weathered surfaces. We infer that the entire upper part of the central volcano is young relative to the underlying median valley floor and that there has been little increase in the layer 2A velocities since emplacement. Layer 2A thins significantly across the axial valley bounding faults likely as the result of footwall uplift. The upper crustal velocities increase with age, on average, at a rate of ~0.875 km/s/Myr, similar to previous measurements at fast spreading ridges, suggesting hydrothermal sealing of small scale porosity is progressing at normal to enhanced rates.
    Print ISSN: 0148-0227
    Topics: Geosciences , Physics
    Published by Wiley on behalf of American Geophysical Union (AGU).
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 90
    Publication Date: 2014-01-14
    Description: A setup has been designed to investigate thin films of confined liquids with the use of X-ray scattering methods. The confinement is realized between the flat culets of a pair of diamonds by positioning and orienting the lower diamond with nanometer and micro radian accuracy. We routinely achieve gaps between 5 and 50 nm at culet diameters of 200 μ m. With this setup and a micro focused X-ray beam we have investigated the in-plane and the out-off-plane atomic order of benzene with atomic resolution.
    Print ISSN: 0034-6748
    Electronic ISSN: 1089-7623
    Topics: Electrical Engineering, Measurement and Control Technology , Physics
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 91
    Publication Date: 2014-01-14
    Description: We have designed and built a Dense Plasma Focus (DPF) Z-pinch device using a kJ-level capacitor bank and a hollow anode, and fueled by a cylindrically symmetric gas puff. Using this device, we have measured peak deuteron beam energies of up to 400 keV at 0.8 kJ capacitor bank energy and pinch lengths of ∼6 mm, indicating accelerating fields greater than 50 MV/m. Neutron yields of on the order of 10 7 per shot were measured during deuterium operation. The cylindrical gas puff system permitted simultaneous operation of DPF with a radiofrequency quadrupole accelerator for beam-into-plasma experiments. This paper describes the machine design, the diagnostic systems, and our first results.
    Print ISSN: 0034-6748
    Electronic ISSN: 1089-7623
    Topics: Electrical Engineering, Measurement and Control Technology , Physics
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 92
    Publication Date: 2014-01-14
    Description: Filamentous fungi cause opportunistic infections in hospital patients. A fast assay to detect viable spores is of great interest. We present a device that is capable of monitoring fungi growth in real time via the dynamic operation of cantilevers in an array. The ability to detect minute frequency shifts for higher order flexural resonance modes is demonstrated using hydrogel functionalised cantilevers. The use of higher order resonance modes sees the sensor dependent mass responsivity enhanced by a factor of 13 in comparison to measurements utilizing the fundamental resonance mode only. As a proof of principle measurement, Aspergillus niger growth is monitored using the first two flexural resonance modes. The detection of single spore growth within 10 h is reported for the first time. The ability to detect and monitor the growth of single spores, within a small time frame, is advantageous in both clinical and industrial settings.
    Print ISSN: 0034-6748
    Electronic ISSN: 1089-7623
    Topics: Electrical Engineering, Measurement and Control Technology , Physics
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 93
    facet.materialart.
    Unknown
    American Institute of Physics (AIP)
    Publication Date: 2014-01-17
    Description: In order to improve the ability and accuracy of measuring the temporal–spatial distribution of the intensity of a large-size, high-energy laser beam, a novel array detecting method based on diffuse transmission sampling is proposed. The measurement principle and the design of the sampling and attenuating unit are presented. High-temperature-resistant diffuse transmission material is used to sample and attenuate a high energy laser beam. Pure copper, whose surface is first sand-blasted and then gold-plated, is applied to scatter the incident high-energy laser beam. The formula for the attenuation ratio was derived in detail. We developed two large-aperture array detectors with spatial resolution of 5 mm, spatial duty ratio of 20%, and useable angle range of ±30° without varying the responsivity, the non-uniformity in the laser profile measurement is below 1%, and the repeatability error in the laser power measurement is approximately 1%. The maximal energy density that the array detector can endure is more than 10 kJ/cm 2 .
    Print ISSN: 0034-6748
    Electronic ISSN: 1089-7623
    Topics: Electrical Engineering, Measurement and Control Technology , Physics
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 94
    Publication Date: 2014-01-17
    Description: A cold finger vacuum cryostat is described in which a sapphire heat conducting element is used to achieve very fast slew rates for a small sample stage over a wide temperature range with optimal matching to a closed cycle helium refrigerator head. When the set temperature is reached it is maintained with very high stability (±5 mK). The target applications are associated with semiconductor electrical material characterisation measurements which require temperature scanning, e.g., thermally stimulated current, deep level transient spectroscopy, and applications which require annealing followed by rapid transition to lower temperature for measurement.
    Print ISSN: 0034-6748
    Electronic ISSN: 1089-7623
    Topics: Electrical Engineering, Measurement and Control Technology , Physics
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 95
    Publication Date: 2014-01-18
    Description: Extremely surface specific information, limited to the first atomic layer of molecular surfaces, is essential to understand the chemistry and physics in upper atmospheric and interstellar environments. Ultra low energy ion scattering in the 1–10 eV window with mass selected ions can reveal extremely surface specific information which when coupled with reflection absorption infrared (RAIR) and temperature programmed desorption (TPD) spectroscopies, diverse chemical and physical properties of molecular species at surfaces could be derived. These experiments have to be performed at cryogenic temperatures and at ultra high vacuum conditions without the possibility of collisions of neutrals and background deposition in view of the poor ion intensities and consequent need for longer exposure times. Here we combine a highly optimized low energy ion optical system designed for such studies coupled with RAIR and TPD and its initial characterization. Despite the ultralow collision energies and long ion path lengths employed, the ion intensities at 1 eV have been significant to collect a scattered ion spectrum of 1000 counts/s for mass selected CH 2 + .
    Print ISSN: 0034-6748
    Electronic ISSN: 1089-7623
    Topics: Electrical Engineering, Measurement and Control Technology , Physics
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 96
    Publication Date: 2014-01-18
    Description: A hollow cathode ion source, based on one developed at Saclay, has been modified significantly and used for several years to produce all primary 1+ ions injected into the Relativistic Heavy Ion Collider Electron Beam Ion Source (EBIS) at Brookhaven. Currents of tens to hundreds of microamperes have been produced for 1+ ions of He, C, O, Ne, Si, Ar, Ti, Fe, Cu, Kr, Xe, Ta, Au, and U. The source is very simple, relying on a glow discharge using a noble gas, between anode and a solid cathode containing the desired species. Ions of both the working gas and ionized sputtered cathode material are extracted, and then the desired species is selected using an ExB filter before being transported into the EBIS trap for charge breeding. The source operates pulsed with long life and excellent stability for most species. Reliable ignition of the discharge at low gas pressure is facilitated by the use of capacitive coupling from a simple toy plasma globe. The source design, and operating experience for the various species, is presented.
    Print ISSN: 0034-6748
    Electronic ISSN: 1089-7623
    Topics: Electrical Engineering, Measurement and Control Technology , Physics
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 97
    Publication Date: 2014-01-18
    Description: An instrument designed for non-destructive mass analysis of single trapped nanoparticles is described. The heart of the instrument is a 3D quadrupole (Paul) trap constructed to give optical access to the trap center along ten directions, allowing passage of lasers for particle heating and detection, particle injection, collection of scattered or fluorescent photons for particle detection and mass analysis, and collection of particles on TEM grids for analysis, as needed. Nanoparticles are injected using an electrospray ionization (ESI) source, and conditions are described for spraying and trapping polymer particles, bare metal particles, and ligand stabilized particles with masses ranging from 200 kDa to 〉3 GDa. Conditions appropriate to ESI and injection of different types of particles are described. The instrument is equipped with two ion guides separating the ESI source and nanoparticle trap. The first ion guide is mostly to allow desolvation and differential pumping before the particles enter the trap section of the instrument. The second is a linear quadrupole guide, which can be operated in mass selective or mass band-pass modes to limit transmission to species with mass-to-charge ratios in the range of interest. With a little experience, the design allows injection of single particles into the trap upon demand.
    Print ISSN: 0034-6748
    Electronic ISSN: 1089-7623
    Topics: Electrical Engineering, Measurement and Control Technology , Physics
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 98
    Publication Date: 2014-01-21
    Description: [1]  High quality streaming potential coupling coefficient measurements have been carried out using a newly designed cell with both a steady-state methodology and a new pressure transient approach. The pressure transient approach has shown itself to be particularly good at providing high quality streaming potential coefficient measurements as each transient increase or decrease allows thousands of measurements to be made at different pressures to which a good linear regression can be fitted. Nevertheless, the transient method can be up to five times as fast as the conventional measurement approaches because data from all flow rates are taken in the same transient measurement rather than separately. Test measurements have been made on samples of Berea and Boise sandstone as a function of salinity (approximately 18 salinities between 10-5 mol/dm3 and 2 mol/dm3). The data have also been inverted to obtain the zeta potential. The streaming potential coefficient becomes greater (more negative) for fluids with lower salinities, which is consistent with existing measurements. Our measurements are also consistent with the high salinity streaming potential coefficient measurements made by Vinogradov et al. (2010). Both the streaming potential coefficient and the zeta potential have also been modeled using the theoretical approach of Glover et al. (2012). This modeling allows the microstructural, electrochemical and fluid properties of the saturated rock to be taken into account in order to provide a relationship that is unique to each particular rock sample. In all cases, we found that the experimental data was a good match to the theoretical model.
    Print ISSN: 0148-0227
    Topics: Geosciences , Physics
    Published by Wiley on behalf of American Geophysical Union (AGU).
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 99
    Publication Date: 2014-01-21
    Description: [1]  The present study, which is a follw-up of the JGR paper by Ji et al. (2013a), provides a new calibration for both seismic and fabric properties of antigorite serpentinites. Comparisons of the laboratory velocities of antigorite serpentinites measured at high pressures with crystallographic preferred orientation (CPO) data measured using electron backscatter diffraction (EBCD) techniques demonstrate that seismic anisotropy in high T serpentinite, which is essentially controlled by the antigorite c-axis fabric, is independent on the operating slip system, but strongly dependent on the regime and magnitude of finite strain experienced by the rock. Extrapolation of the experimental data with both pressure and temperature suggests that V p anisotropy decreases but shear wave splitting (Δ V s ) and V p / V s increase with increasing pressure in either cold or hot subduction zones. For a cold, steeply subducting slab, antigorite is most likely deformed by nearly coaxial flattening or trench-parallel movements, forming trench-parallel seismic anisotropy. For a hot, shallowly subducting slab, however, antigorite is most likely deformed by simple shear or transpression. Trench-normal seismic anisotropy can be observed when the subducting dip angle is smaller than 30°. The geophysical characteristics of the Tibetan Plateau such as strong heterogeneity in V p , V s and attenuation, shear wave splitting and electric conductivity may be explained by the presence of strongly deformed serpentinites in lithospheric shear zones reactivated along former suture zones between amalgamated blocks, hydrated zones of subducting lithospheric mantle, and the crust-mantle boundary if the temperature is below 700 °C in the region of interest.
    Print ISSN: 0148-0227
    Topics: Geosciences , Physics
    Published by Wiley on behalf of American Geophysical Union (AGU).
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 100
    Publication Date: 2014-01-22
    Description: [1]  We explore the concept of maximum possible earthquake magnitude, M , in a region represented by an earthquake catalog from the viewpoint of statistical testing. For this aim, we assume that earthquake magnitudes are independent events that follow a doubly-truncated Gutenberg-Richter distribution and focus on the upper truncation M . In earlier work, it has been shown that the value of M cannot be well constrained from earthquake catalogs alone. However, for two hypothesized values M and M ′, alternative statistical tests may address the question: Which value is more consistent with the data? In other words: Is it possible to reject a magnitude within reasonable errors, i.e. the error of the first and the error of the second kind? The results for realistic settings indicate that either the error of the first kind or the error of the second kind is intolerably large. We conclude that it is essentially impossible to infer M in terms of alternative testing with sufficient confidence from an earthquake catalog alone, even in regions like Japan with excellent data availability. These findings are also valid for frequency-magnitude distributions with different tail behavior, e.g. exponential tapering. Finally, we emphasize that different data may only be useful to provide additional constraints for M , if they do not correlate with the earthquake catalog, i.e. if they have not been recorded in the same observational period. In particular, longterm geological assessments might be suitable to reduce the errors, while GPS measurements provide overall the same information as the catalogs.
    Print ISSN: 0148-0227
    Topics: Geosciences , Physics
    Published by Wiley on behalf of American Geophysical Union (AGU).
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...