ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Other Sources  (4)
  • ddc:550.724  (3)
  • soft X‐rays  (2)
  • International Union of Crystallography  (4)
  • American Chemical Society
  • American Physical Society
  • Wiley
  • 2020-2024  (4)
  • 1980-1984
  • 1965-1969
  • 1950-1954
Collection
  • Other Sources  (4)
Source
Publisher
Language
Years
  • 2020-2024  (4)
  • 1980-1984
  • 1965-1969
  • 1950-1954
Year
  • 1
    Publication Date: 2024-03-13
    Description: The PERCIVAL detector is a CMOS imager designed for the soft X‐ray regime at photon sources. Although still in its final development phase, it has recently seen its first user experiments: ptychography at a free‐electron laser, holographic imaging at a storage ring and preliminary tests on X‐ray photon correlation spectroscopy. The detector performed remarkably well in terms of spatial resolution achievable in the sample plane, owing to its small pixel size, large active area and very large dynamic range; but also in terms of its frame rate, which is significantly faster than traditional CCDs. In particular, it is the combination of these features which makes PERCIVAL an attractive option for soft X‐ray science.
    Keywords: ddc:548 ; X‐ray detectors ; soft X‐rays ; ptychography ; holographic imaging ; XPCS ; detectors
    Language: English
    Type: doc-type:article
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Publication Date: 2024-02-05
    Description: 〈p xmlns:mml="http://www.w3.org/1998/Math/MathML" xml:lang="en"〉Penetrating, high‐energy synchrotron X‐rays are in strong demand, particularly for high‐pressure research in physics, chemistry and geosciences, and for materials engineering research under less extreme conditions. A new high‐energy wiggler beamline P61 has been constructed to meet this need at PETRA III in Hamburg, Germany. The first part of the paper offers an overview of the beamline front‐end components and beam characteristics. The second part describes the performance of the instrumentation and the latest developments at the P61B endstation. Particular attention is given to the unprecedented high‐energy photon flux delivered by the ten wigglers of the PETRA III storage ring and the challenges faced in harnessing this amount of flux and heat load in the beam. Furthermore, the distinctiveness of the world's first six‐ram Hall‐type large‐volume press, Aster‐15, at a synchrotron facility is described for research with synchrotron X‐rays. Additionally, detection schemes, experimental strategies and preliminary data acquired using energy‐dispersive X‐ray diffraction and radiography techniques are presented.〈/p〉
    Description: 〈p xmlns:mml="http://www.w3.org/1998/Math/MathML" xml:lang="en"〉The operation of the P61B endstation large‐volume press and optics of P61 are reviewed. The instrumentation at P61B, including the large‐volume press, detection systems and data acquisition for 〈italic〉in situ〈/italic〉 high‐pressure experiments are described.〈boxed-text position="anchor" content-type="graphic" xml:lang="en"〉〈graphic position="anchor" id="jats-graphic-1" xlink:href="urn:x-wiley:16005775:jsy2ju5040:jsy2ju5040-fig-0001"〉 〈/graphic〉〈/boxed-text〉〈/p〉
    Keywords: ddc:550.724 ; extreme conditions ; high‐pressure ; large‐volume press ; energy‐dispersive X‐ray diffraction ; radiography ; resistive heating ; ultrasonic interferometry ; acoustic emissions detection
    Language: English
    Type: doc-type:article
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Publication Date: 2024-01-12
    Description: A split‐and‐delay unit for the extreme ultraviolet and soft X‐ray spectral regions has been built which enables time‐resolved experiments at beamlines FL23 and FL24 at the Free‐electron LASer in Hamburg (FLASH). Geometric wavefront splitting at a sharp edge of a beam splitting mirror is applied to split the incoming soft X‐ray pulse into two beams. Ni and Pt coatings at grazing incidence angles have been chosen in order to cover the whole spectral range of FLASH2 and beyond, up to hν = 1800 eV. In the variable beam path with a grazing incidence angle of ϑd = 1.8°, the total transmission (T) ranges are of the order of 0.48 〈 T 〈 0.84 for hν 〈 100 eV and T 〉 0.50 for 100 eV 〈 hν 〈 650 eV with the Ni coating, and T 〉 0.06 for hν 〈 1800 eV for the Pt coating. For a fixed beam path with a grazing incidence angle of ϑf = 1.3°, a transmission of T 〉 0.61 with the Ni coating and T 〉 0.23 with a Pt coating is achieved. Soft X‐ray pump/soft X‐ray probe experiments are possible within a delay range of −5 ps 〈 Δt 〈 +18 ps with a nominal time resolution of tr = 66 as and a measured timing jitter of tj = 121 ± 2 as. First experiments with the split‐and‐delay unit determined the averaged coherence time of FLASH2 to be τc = 1.75 fs at λ = 8 nm, measured at a purposely reduced coherence of the free‐electron laser.
    Description: The properties of the recently installed split‐and‐delay unit at beamlines FL23 and FL24 at FLASH2 are presented. Its operational range, performance parameters and results of a first experiment are described. image
    Keywords: ddc:550.724 ; time‐resolved pump–probe ; XUV ; soft X‐rays ; free‐electron laser
    Language: English
    Type: doc-type:article
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Publication Date: 2023-10-24
    Description: 〈p xmlns:mml="http://www.w3.org/1998/Math/MathML" xml:lang="en"〉Complex functional materials play a crucial role in a broad range of energy‐related applications and in general for materials science. Revealing the structural mechanisms is challenging due to highly correlated coexisting phases and microstructures, especially for 〈italic〉in situ〈/italic〉 or 〈italic〉operando〈/italic〉 investigations. Since the grain sizes influence the properties, these microstructural features further complicate investigations at synchrotrons due to the limitations of illuminated sample volumes. In this study, it is demonstrated that such complex functional materials with highly correlated coexisting phases can be investigated under 〈italic〉in situ〈/italic〉 conditions with neutron diffraction. For large grain sizes, these experiments are valuable methods to reveal the structural mechanisms. For an example of 〈italic〉in situ〈/italic〉 experiments on barium titanate with an applied electric field, details of the electric‐field‐induced phase transformation depending on grain size and frequency are revealed. The results uncover the strain mechanisms in barium titanate and elucidate the complex interplay of stresses in relation to grain sizes as well as domain‐wall densities and mobilities.〈/p〉
    Description: 〈p xmlns:mml="http://www.w3.org/1998/Math/MathML" xml:lang="en"〉This work reports 〈italic〉in situ〈/italic〉 neutron diffraction experiments on a broad range of grain sizes of barium titanate. The study reveals the grain‐size‐dependent strain mechanisms and shows the competitiveness of neutron diffraction with high‐resolution synchrotron diffraction.〈boxed-text position="anchor" content-type="graphic" xml:lang="en"〉〈graphic position="anchor" id="jats-graphic-1" xlink:href="urn:x-wiley:16005767:jcr2vb5054:jcr2vb5054-fig-0001"〉 〈alt-text〉image〈/alt-text〉 〈/graphic〉〈/boxed-text〉〈/p〉
    Keywords: ddc:550.724 ; ddc:548 ; neutron diffraction ; in situ ; applied electric fields ; barium titanate ; strain mechanisms ; grain sizes ; complex functional materials ; microstructures ; coexisting phases
    Language: English
    Type: doc-type:article
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...