ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Articles  (217)
  • Articles: DFG German National Licenses  (217)
  • Life and Medical Sciences  (217)
  • 1985-1989  (217)
  • 1940-1944
  • Physics  (217)
Collection
  • Articles  (217)
Source
  • Articles: DFG German National Licenses  (217)
Publisher
Years
Year
Topic
  • 11
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 6 (1985), S. 89-97 
    ISSN: 0197-8462
    Keywords: CW ; pulsed ; amplitude modulation ; microwaves ; brain ; metabolism ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: A comparison of the effects of continuous-wave, sinusoidal-amplitude-modulated, and pulsed square-wave-modulated 591-MHz microwave exposures on brain energy metabolism was made in male Sprague-Dawley rats (175-225 g). Brain NADH fluorescence, adenosine triphosphate (ATP) concentration, and creatine phosphate (CP) concentration were determined as a function of modulation frequency. Brain temperatures of animals were maintained between -0.1 and -0.4°C from the preexposure temperature when subjected to as much as 20 mW/cm2 (average power) CW, pulsed, or sinusoidal-amplitude modulated 591-MHz radiation for 5 min. Sinusoidal-amplitude-modulated exposures at 16-24 Hz showed a trend toward preferential modulation frequency response in inducing an increase in brain NADH fluorescence. The pulse-modulated and sinusoidal-amplitudemodulated (16 Hz) microwaves were not significantly different from CW exposures in inducing increased brain NADH fluorescence and decreased ATP and CP concentrations. When the pulse-modulation frequency was decreased from 500 to 250 pulses per second the average incident power density threshold for inducing an increase in brain NADH fluorescence increased by a factor of 4 - ie, from about 0.45 to about 1.85 mW/cm2. Since brain temperature did not increase, the microwave-induced increase in brain NADH and decrease in ATP and CP concentrations was not due to hyperthermia. This suggests a direct interaction mechanism and is consistent with the hypothesis of microwave inhibition of mitochondrial electron transport chain function of ATP production.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 12
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 6 (1985), S. 99-103 
    ISSN: 0197-8462
    Keywords: electric fields ; 60-Hz ; detection ; female ; sex ; psychophysics ; behavior ; rats ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: Female rats were trained to detect a vertical, 60-Hz electric field using the same apparatus and procedure we used previously to study behavioral detection of the field by male rats. Each rat was trained individually to press a lever in the presence of the field and not to press in its absence. Correct detections occasionally produced a food pellet. The probability of detecting the field increased as field strength increased. The threshold of detection  - ie, the field strength required for detections at a probability of 0.5 after correction for errors - varied among rats between 3 and 10 kV/m. Behavioral detection by female rats was indistinguishable from that by male rats.
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 13
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 6 (1985), S. 115-129 
    ISSN: 0197-8462
    Keywords: radiofrequency ; dosimetry ; near-field exposure ; SAR distribution ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: The spatial distribution of the specific absorption rate (SAR) was measured in a full-scale model of man using implantable electric field probes. The model was exposed in the near-field of linear and aperture antennas at 350 MHz. Effects of the wave polarization, antenna position and antenna gain on the SAR distribution and the average SAR in the whole-body and body parts are reported.
    Additional Material: 12 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 14
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 6 (1985), S. 145-156 
    ISSN: 0197-8462
    Keywords: active microwave imaging ; diffraction tomography ; perfused organs ; non-invasive thermometry ; hyperthermia ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: The relative transparency of biological materials to high-frequency electromagnetic waves has encouraged the development of new systems for imaging. This report describes experiments of microwave tomography conducted on a prototype. The object to be analyzed is submerged in water and is illuminated by a plane wave. The total electric field is analyzed by a microwave camera. The recorded data are then processed numerically in order to reconstruct the image that corresponds to the distribution of equivalent currents in a defined plane of a section. Experiments have been conducted on isolated kidneys with and without perfusion. The influence of the perfusing solution temperature has also been studied. These experiments show the potential of this system, especially through the correlation between microwave images and the biological structures. They also confirm previous results concerning spatial resolution and depth of exploration. Finally, the results demonstrate the influence of temperature and support the applicability of this imaging system in non-invasive thermometry, especially for clinical hyperthermia.
    Additional Material: 10 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 15
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 6 (1985), S. 207-207 
    ISSN: 0197-8462
    Keywords: Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 16
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 6 (1985), S. 209-220 
    ISSN: 0197-8462
    Keywords: theoretical dosimetry ; electric field ; 60 Hz ; ELF ; power frequency ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: Power-frequency electric fields are strongly perturbed in the vicinity of human beings and experimental animals. As a consequence, the extrapolation of biological data from laboratory animals to human-exposure situations cannot use the unperturbed exposure field strength as a common exposure parameter. Rather, comparisons between species must be based on the actual electric fields at the outer surfaces of and inside the bodies of the subjects. Experimental data have been published on surface and internal fields for a few exposure situations, but it is not feasible to characterize experimentally more than a small fraction of the diverse types of exposures which occur in the laboratory and in the field. A predictive numerical model is needed, one whose predictions have been verified in situations where experimental data are available, and one whose results can be used with confidence in new exposure situations. This paper describes a numerical technique which can be used to develop such a model, and it carries out this development for a test case, that of a homogeneous right-circular cylinder resting upright on-end on a ground plane and exposed to a vertical, uniform, 60-Hz electric field. The accuracy of the model is tested by comparing short-circuit currents and induced current densities predicted by it to measured values: Agreement is good.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 17
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 6 (1985), S. 221-234 
    ISSN: 0197-8462
    Keywords: 2,450-MHz CW microwaves ; Saimiri sciureus ; metabolism ; temperatures ; vasodilation ; thermoregulation ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: The present study was undertaken to investigate the thermal adjustments of squirrel monkeys exposed in a cold environment to relatively high energy levels of microwave fields. The animals (Saimiri sciureus) were equilibrated for 90 min to a cool environment (Ta = 20°C) to elevate metabolic heat production (M). They were then exposed for brief (10-min) or long (30-min) periods to 2,450-MHz continuous-wave microwaves. Power densities (MPD) were 10, 14, 19, and 25 mW/cm2 during brief exposures and 30, 35, 40, and 45 mW/cm2 during long exposures (rate of energy absorption: SAR = 0.15 [W/kg]/ [mW/cm2]). Individual exposures were separated by enough time to allow physiological variables to return to baseline levels. The results confirm that each microwave exposure induced a rapid decrease in M. In a 20°C environment, the power density of a 10-min exposure required to lower M to approximate the resting level was 35 mW/cm2 (SAR = 5.3 W/kg). During the long exposures, 20 min was needed to decrease M to its lowest level. Cessation of irradiation was associated with persistence of low levels of M for periods that depended on the power density of the preceding microwave exposure. Vasodilation, as indexed by changes in local skin temperature, occurred at a high rate of energy absorption (SAR = 4.5 W/kg) and was sufficient to prevent a dramatic increase in storage of thermal energy by the body; vasoconstriction was reinstated after termination of irradiation. Patterns of thermophysiological responses confirm the influence both of peripheral and of internal inputs to thermoregulation in squirrel monkeys exposed to microwaves in a cool environment.
    Additional Material: 10 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 18
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 6 (1985), S. 283-291 
    ISSN: 0197-8462
    Keywords: electric field ; growth ; cell elongation ; tranmembrane potential ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: Roots of Pisum sativum were exposed for 48 h to 60-Hz electric fields of 430 V/m in an aqueous inorganic growth medium. The growth in length of the exposed roots was 44% of that for control roots. Root tips were analyzed for mitotic index and cell cycle duration. Mature, differentiated root sections from tissue produced after electrode energization were analyzed for cell lengths and number of files. The major reason for the observation that exposed roots are shorter than control roots is that cell elongation in the former is greatly diminished relative to controls.
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 19
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 6 (1985), S. 323-326 
    ISSN: 0197-8462
    Keywords: rat ; 2,450-MHz ; circular waveguide ; auditory-brainstem-evoked response ; hearing effect ; pulsed microwaves ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: Rats were exposed to 2,450-MHz pulsed microwave fields in a circularly polarized waveguide. The threshold incident energy density per pulse was about 1.5 to 3 μJ/cm2 over the range 1-10 μs. The corresponding whole-body averaged specific absorption of energy was 0.9 to 1.8 mJ/kg per pulse. The same response was evoked when the incident energy density or absorbed energy density per pulse was the same, regardless of the pulse widths.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 20
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 6 (1985), S. 313-322 
    ISSN: 0197-8462
    Keywords: RF radiation ; red cell (erythrocyte) hemolysis ; field-strength-dependent threshold ; sensitive subpopulation ; irreversible membrane alteration ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: A field-strength-dependent hemolytic effect of continuous-wave radiofrequency (RF) exposure in vitro has been demonstrated. Erythrocytes in whole heparinized rabbit blood were hemolyzed by a 2-h exposure to 50- or 100-MHz RF fields at field strengths of greater than 4 V/cm. An effect of comparable magnitude resulted from exposure to 10-MHz RF at a field strength of 9 V/cm. Sample temperatures were maintainted at 22.5° ± 0.2°C. There was no apparent involvement of heating or temperature gradients, nor were there any RF exposure effects on cellular K+ or Na+ concentration, nor on pH. The mechanism of the hemolytic effect is not known. Since the percentage of lysed erythrocytes was less than 1% and there was an absence of effects on cellular cation concentrations, RF radiation may have irreversibly altered the plasma membrane permeability of a sensitive subpopulation of red cells (possibly aged cells) leading to osmotic lysis. RF radiation at these frequencies appears to affect red cells in a manner that is qualitatively and quantitatively different from microwave radiation.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...