ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Articles  (38,020)
  • Articles: DFG German National Licenses  (38,020)
  • Springer  (38,020)
  • 2020-2024
  • 1985-1989  (38,020)
  • Physics  (38,020)
Collection
  • Articles  (38,020)
Source
Keywords
Years
Year
  • 11
    Electronic Resource
    Electronic Resource
    Springer
    Lasers in medical science 1 (1986), S. 81-84 
    ISSN: 1435-604X
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine , Physics , Technology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 12
    Electronic Resource
    Electronic Resource
    Springer
    Lasers in medical science 1 (1986), S. 85-86 
    ISSN: 1435-604X
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine , Physics , Technology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 13
    ISSN: 1435-604X
    Keywords: Argon dye laser ; Photodynamic therapy ; Gastric cancer ; Adenocarcinomas
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine , Physics , Technology
    Notes: Abstract Twenty-eight patients with gastric cancer were treated by photodynamic therapy. Haematoporphyrin derivative was used as a photosensitizer and an argon dye laser as a light source. Histologically, all tumours were adenocarcinomas. On the basis of endoscopy, 17 cases were categorized as early-stage cancer and were classified as type IIc (10 lesions), Ha (three lesions), combined type IIc and type III (three lesions) and type I (two lesions). In 11 patients with advanced-stage cancer, endoscopy showed one case of Borrmann I, three of Borrmann II, six of Borrmann III and a single case of Borrmann IV. In the 17 patients with early-stage cancers (18 lesions), complete remission was obtained in 10 patients (11 lesions). Of 13 resected cancers complete remission was confirmed in six lesions on the basis of detailed histological examination of resected specimens. In the advanced stage tumours all 11 patients showed incomplete remissions. It is considered that an incomplete response in the early-stage cancers is due to insufficient light dosage because of the wide area of tumour, because the site of the lesion is anatomically difficult to photoradiate and because the invasion extends to the muscular layer and serosa.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 14
    ISSN: 1435-604X
    Keywords: Laser angioplasty ; Excimer laser ; Photoablation ; Haemolysis
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine , Physics , Technology
    Notes: Abstract The effects of three ultraviolet excimer laser wavelengths on normal and atheromatous human cadaver aortic wall are presented. Ultraviolet radiation successfully ablates vessel wall; the dose response is greatest at 249 nm followed by 193 nm and 351 nm, where the effect is negligible for the equivalent energy dose. Wavelengths 249 and 193 nm have a selective effect on fibrous atheroma; ablation proceeds at a higher rate in this tissue. Non-linear effects observed at 249 nm may be due to thermal as well as photoablative mechanisms. In addition, blood samples were exposed to all three wavelengths and potassium concentrations were measured; the dose of energy required to produce tissue ablation may also produce significant haemolysis and hyperkalaemia at 249 and 193 nm but not with 351 nm. This finding may be important for coronary angioplasty but less so for peripheral work. The wavelength that produces the strongest dose response is 249 nm; this is the wavelength for which a fibre-optic delivery system should be developed.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 15
    ISSN: 1435-604X
    Keywords: Argon laser ; Superficial venular dilatation lower limb ; Arborizing telangiectasia
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine , Physics , Technology
    Notes: Abstract The response of vascular dilatation of the lower limb to treatment with the argon laser was found to correlate with clinical diagnosis. Nine patients with superficial venular dilatation of the lower limb associated with varicose veins were treated with the argon laser and the results were uniformly poor. However, two patients with the clinically distinct condition of arborizing telangiectasia (or essential progressive telangiectasia) of the legs responded well to treatment. No other satisfactory treatment is available for this cosmetically distressing condition, so that argon laser therapy appears to be the treatment of choice.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 16
    ISSN: 1435-604X
    Keywords: Neodymium-YAG laser ; Meningioma ; Microsurgery ; Micromanipulator
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine , Physics , Technology
    Notes: Abstract The coagulation and tumour-shrinking properties of the Nd-YAG laser make it a useful tool in the treatment of vascular intracranial tumours, in particular meningiomas. The resection of many tumours such as base-of-skull meningiomas inevitably involves limited access, making precision work with the hand-held laser difficult. This paper presents the use of a special micromanipulator which allows coupling of the OPMILas YAG laser to the Zeiss OPMI operating microscope. The laser can be used in focused or defocused mode, with better precision than that obtained in the hand-held position. A built-in filter makes the instrument safe for the surgeon to use without goggles.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 17
    Electronic Resource
    Electronic Resource
    Springer
    Lasers in medical science 1 (1986), S. 221-224 
    ISSN: 1435-604X
    Keywords: Lasers ; Exposure time ; Calibration ; Safety
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine , Physics , Technology
    Notes: Abstract A hand-held unit has been constructed for routine measurement of exposure times of argon and krypton lasers. A small photodiode is used as the sensing element, and the measured exposure time in ms is observed on a liquid-crystal display. A series of measurements was made on a set of four lasers in use in ophthalmology departments in North Wales. Typically, the measured exposure times were observed to agree well with set values. Percentage errors were, however, often considerable at the shortest exposure settings. A small variation in values of exposure timings for a selected exposure time was found as a function of selected aiming-beam position. This presumably arises out of the design of the particular aiming-beam/shutter assembly. Although no serious shutter malfunction was detected, the ability to measure exposure times accurately was considered relevant to checking the delivered output of laser systems.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 18
    Electronic Resource
    Electronic Resource
    Springer
    Lasers in medical science 1 (1986), S. 225-228 
    ISSN: 1435-604X
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine , Physics , Technology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 19
    Electronic Resource
    Electronic Resource
    Springer
    Lasers in medical science 1 (1986), S. 229-230 
    ISSN: 1435-604X
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine , Physics , Technology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 20
    Electronic Resource
    Electronic Resource
    Springer
    Lasers in medical science 1 (1986), S. 231-231 
    ISSN: 1435-604X
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine , Physics , Technology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...