Operation of rich single-photon detectors with optically shielded wires in transverse magnetic fields

https://doi.org/10.1016/0168-9002(86)91216-7Get rights and content

Abstract

The operation of TPC-type photon detectors with optical shields between the sense wires has been investigated in magnetic fields up to 1.4 T. The field was applied perpendicularly to the drift direction. Three types of MWPCs with different optical shield designs were tested. Ethane and iso-butane were used as drift gases. TMAE vapour was added to obtain photon sensitivity.

The results show that MWPCs with printed circuit board shields can be operated without loss of efficiency even at high magnetic fields. The MWPC with tubular cathode shows losses already at low fields.

References (7)

  • E. Barrelet et al.

    Nucl. Instr. and Meth.

    (1982)
  • T. Ekelöf et al.

    Phys. Scripta

    (1981)
  • L.O. Eek et al.

    IEEE Trans. Nucl. Sci. NS-31

    (1984)
There are more references available in the full text version of this article.

Cited by (9)

  • Performance of the ring imaging Cherenkov detector of DELPHI

    1995, Nuclear Inst. and Methods in Physics Research, A
  • The ring imaging Cherenkov detector of DELPHI

    1994, Nuclear Inst. and Methods in Physics Research, A
  • The forward ring imaging Cherenkov detector of DELPHI

    1994, Nuclear Inst. and Methods in Physics Research, A
  • The DELPHI detector at LEP

    1991, Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
  • The multiwire proportional chambers of the DELPHI Barrel rich

    1988, Nuclear Inst. and Methods in Physics Research, A
  • Lorentz angle studies for the SLD endcap Cherenkov Ring Imaging detector

    1988, Nuclear Inst. and Methods in Physics Research, A
View all citing articles on Scopus