Magnesium selective electrodes for blood serum studies and water hardness measurement

  • Original Papers
  • Published:
Microchimica Acta Aims and scope Submit manuscript

Abstract

Magnesium selective ionophores are described which induce a rejection of Na+ and K+ in solvent polymeric membranes by factors of up to 6300 and 5000, respectively. Depending on the membrane composition, ion selective electrodes may be obtained with equal selectivity for Mg2+ and Ca2+ as well as sensors with a discrimination of Ca2+ by a factor up to 8. Sensors of the type described are candidates for water hardness determination as well as for an Mg2+ assay in blood by chemometric procedures.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. M. V. Rouilly, M. Badertscher, E. Pretsch, G. Suter, W. Simon,Anal. Chem. 1988,60, 2013.

    Google Scholar 

  2. M. Otto, J. D. R. Thomas,Anal. Chem. 1985,57, 2647.

    Google Scholar 

  3. S. K. A. G. Hassan, G. J. Moody, J. D. R. Thomas,Analyst 1980,105, 147.

    Google Scholar 

  4. P. C. Meier, D. Erne, Z. Cimerman, D. Ammann, W. Simon,Mikrochim. Acta [Wien] 1980,I, 317.

    Google Scholar 

  5. U. Oesch, Z. Brzózka, A. Xu, B. Rusterholz, G. Suter, H.-V. Pham, D. H. Welti, D. Ammann, E. Pretsch, W. Simon,Anal. Chem. 1986,58, 2285.

    Google Scholar 

  6. G. G. Guilbault, R. A. Durst, M. S. Frant, H. Freiser, E. H. Hansen, T. S. Light, E. Pungor, G. Rechnitz, N. M. Rice, T. J. Rohm, W. Simon, J. D. R. Thomas,Pure Appl. Chem. 1976,48, 127.

    Google Scholar 

  7. P. C. Meier,Anal. Chim. Acta 1982,136, 363.

    Google Scholar 

  8. U. Oesch, W. Simon,Anal. Chem. 1980,52, 692.

    Google Scholar 

  9. P. C. Meier, D. Ammann, W. E. Morf, W. Simon, in:Medical and Biological Applications of Electrochemical Devices (J. Koryta, ed.), Wiley, Chichester, New York-Brisbane-Toronto, 1980, p. 13.

    Google Scholar 

  10. M. Huser, E. Pungor, W. Simon (in preparation).

  11. E. Lindner, K. Tóth, E. Pungor, T. R. Berube, R. P. Buck,Anal. Chem. 1987,59, 2213.

    Google Scholar 

  12. P. Gehrig, W. E. Morf, E. Pretsch, W. Simon (in preparation).

  13. P. C. Meier, W. E. Morf, M. Läubli, W. Simon,Anal. Chim. Acta 1984,156, 1.

    Google Scholar 

  14. J. W. Ross, Jr.,Ion-Selective Electrodes (R. A. Durst, ed.), (NBS Spec. Publ. 314), Department of Commerce, National Bureau of Standards, Washington, DC, 1969, p. 70.

    Google Scholar 

  15. D. Erne, W. E. Morf, S. Arvanitis, Z. Cimerman, D. Ammann, W. Simon,Hel. Chim. Acta 1979,62, 994.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Additional information

On leave from the Chemistry Department, University of Warsaw, ul. L. Pasteura 1, PL-02-093 Warsaw, Poland

On leave from the Shanghai University of Technology, 149 Yanchang Road, Shanghai, People's Republic of China

Rights and permissions

Reprints and permissions

About this article

Cite this article

Müller, M., Rouilly, M., Rusterholz, B. et al. Magnesium selective electrodes for blood serum studies and water hardness measurement. Mikrochim Acta 96, 283–290 (1988). https://doi.org/10.1007/BF01236112

Download citation

  • Received:

  • Revised:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF01236112

Key words

Navigation