An analogue circuit for the computation of stroke volume by the electrical impedance method

  • Published:
Medical and biological engineering Aims and scope Submit manuscript

Abstract

An analogue circuit is described for use in conjunction with thedZ/dt, e.c.g. and phonocardiogram signals from an IFM Impedance Cardiograph to measure stroke volume. This is displayed on a digital meter. The circuit can be extended to measure cardiac output.

Sommaire

L'article décrit un circuit analogue servant à mesurer les volumes de battement pour usage en conjonction avec l'e.c.g.dZ/dt et les signaux phonocardiogrammes produits par un cardiographe d'impédance IFM. L'affichage est effectué sur un cadran numérique. Ce circuit peut être étendu pour mesurer le rendement cardiaque.

Zussammenfassung

Es wird eine Analogschaltung zum Einsatz in Verbindung mit dendZ/dt-, e.k.g.-und Phonokardiogrammsignalen von einem IFM-Impedanz-Kardiographen zur Messung des Hubvolumens beschrieben. Die Anzeige erfolgt auf einem digitalen Meßgerät. Die Schaltung kann zur Messung der Herzleistung erweitert werden.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Geddes, L. A. andSadler, C. (1973) The specific resistance of blood at body temperature.Med. & Biol. Engng. 11, 336–339.

    Article  Google Scholar 

  • Hill, D. W. andPayne, J. P. (1972) The use of analogue telephone data links for the transmission of physiological signals.Brit. J. Anaesth. 44, 562–568.

    Google Scholar 

  • Hill, D. W. andLowe, H. J. (1973) The use of the electrical-impedance technique for the monitoring of cardiac output and limb blood flow during anaesthesia.Med. & Biol. Engng. 11, 534–545.

    Google Scholar 

  • Hill, D. W. andThompson, F. D. (1975) The effect of haematocrit on the resistivity of human blood at 37°C and 100 kHz.Med. & Biol. Engng. 13,

  • Kubicek, W. G., Karnegis, J. N., Patterson, R. B., Witsoe, D. A. andMattson, R. H. (1966) Development and evaluation of an impedance cardiac output system.Aerospace Med. 37, 1208.

    Google Scholar 

  • Sandman, A. M. (1968) Mark/space-ratio generator.Electron. Engng. 40, 474.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Sandman, A.M., Hill, D.W. & Mable, S.E.R. An analogue circuit for the computation of stroke volume by the electrical impedance method. Med. & biol. Engng. 14, 74–78 (1976). https://doi.org/10.1007/BF02477094

Download citation

  • Received:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02477094

Keywords

Navigation