Polarographische Bestimmung von Cumolhydroperoxid und Dicumylperoxid nebeneinander in technologischen Mischungen

Polarographic determination of cumene hydroperoxide and dicumyl peroxide in presence of each other in technological mixtures

  • Originalabhandlungen
  • Published:
Fresenius' Zeitschrift für analytische Chemie Aims and scope Submit manuscript

Abstract

The determination was carried out in a supporting electrolyte consisting of LiCl and KCl in ethanol for the first and of tetramethylammonium chloride in dimethylformamide for the latter compound. Triphenylphosphine was employed for the reduction of cumene hydroperoxide, which interfered with the dicumyl peroxide determination. Relative errors were +- 5%.

Zusammenfassung

Für die polarographische Bestimmung von Cumolhydroperoxid wurde LiCl + KCl in Äthanol als Grundelektrolyt verwendet, für Dicumylperoxid Tetramethylammoniumchlorid in Dimethylformamid. Bei der Peroxidbestimmung störendes Hydroperoxid wurde mit Triphenylphosphin reduziert. Die relativen Fehler betrugen +- 5%.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

Literatur

  1. Antonowski, W. L., Poladian, W. E.: Ž. Anal. Chim. 19, 248 (1964)

    Google Scholar 

  2. Baranowski, R., Gregorowicz, Z., Kulicka, J., Kulicki, Z.: Chem. Anal. (Warsaw) 11, 135 (1966)

    Google Scholar 

  3. Bernhauer, K., Meyer, H.: Monatsh. Chem. 53, 721 (1929)

    Google Scholar 

  4. Blanchard, H. S.: J. Am. Chem. Soc. 81, 4548 (1959)

    Google Scholar 

  5. Horner, L., Jurgeleit, W.: Liebigs Ann. Chem. 591, 138 (1955)

    Google Scholar 

  6. Kulicki, Z.: Zesz. Nauk. Politech. Ślask. Chem. 36, 61 (1967)

    Google Scholar 

  7. Mair, R. D., Hall, R. T.: Determination of Organic Peroxides by Physical, Chemical and Colorimetric Methods in Organic Peroxides, D. Swern ed., Vol. II, pp. 537–635. New York: Wiley Intersci. (1971)

    Google Scholar 

  8. Martin, A. J.: Determination of Organic Peroxides in Organic Analysis, J. Mitchell, Jr., ed., Vol. IV, pp. 1–64. New York: Interscience 1960

    Google Scholar 

  9. Supniewski, J.: Preparatyka nieorganiczna, Warszawa 1950

Download references

Author information

Authors and Affiliations

Authors

Additional information

Der Gehalt der Substanzen wurde auf Grund von Eichkurven errechnet. Der relative maximale Fehler bei der Bestimmung des Hydroperoxids und des Dicumylperoxids betrug +- 5%.