Skip to main content
Log in

Monte Carlo simulation of molecular flow in a neutral beam injector and comparison with experiment

  • Contributed Papers
  • Published:
Journal of Fusion Energy Aims and scope Submit manuscript

Abstract

Monte Carlo calculations have been performed to obtain estimates of the background gas pressure and molecular number density as a function of position in the PDX-prototype neutral beam injector, which has undergone testing at the Oak Ridge National Laboratory. Estimates of these quantities together with the transient and steady-state energy deposition and molecular capture rates on the cryopanels of the cryocondensation pumps and the molecular escape rate from the injector were obtained utilizing a detailed geometric model of the neutral beam injector. The molecular flow calculations were performed using an existing Monte Carlo radiation transport code, which was modified slightly to monitor the energy of the background gas molecules. The credibility of these calculations is demonstrated by the excellent agreement between the calculated and experimentally measured background gas pressure in front of the beamline calorimeter located in the downstream drift region of the injector. The usefulness of the calculational method as a design tool is illustrated by a comparison of the integrated beamline molecular density over the drift region of the injector for three modes of cryopump operation.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. M. B. Emmett, The MORSE Monte Carlo radiation transport system, ORNL-4972, Oak Ridge National Laboratory (1975).

  2. W. L. Gardner, et al., The ORNL prototype PDX neutral beam injection system,IEEE 8th Symp. Eng. Problems of Fusion Res., San Francisco (1979).

  3. J. T. West, JUNEBUG—a three dimensional geometry plotting code, ORNL/NUREG/CSD-2/V2, Oak Ridge National Laboratory.

  4. A. E. Mensing, D. J. McFarlin, R. F. Dondero, and T. S. Latham, Cryocondensation vacuum pump final report under Union Carbide Corp. Purchase Order 72Y48600V, R-78-954156-1, United Technologies Research Center (1978).

  5. D. H. Davis, Monte Carlo calculation of molecular flow rates through a cylindrical elbow and pipes of other shapes,J. Appl. Phys. 37 (1969).

  6. E. H. Kennard,Kinetic Theory of Gases (McGraw-Hill, New York, 1938).

    Google Scholar 

  7. F. Arnold, R. Dawbarn, and M. R. Busby, Interaction of a mono-energetic nitrogen molecular beam with a solid nitrogen surface,Appl. Phys. Lett. 17 (1970).

  8. G. K. White,Experimental Techniques in Low Temperature Physics (Oxford University Press, London, 1959).

    Google Scholar 

  9. L. E. Weaver,System Analysis of Nuclear Reactor Dynamics (Rowman and Littlefield, Inc., New York, 1963).

    Google Scholar 

  10. L. E. Valby, Cryopumping system for TFTR neutral beam injectors,IEEE 7th Symp Eng. Problems of Fusion Res., Knoxville, Tenn. (1977).

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Lillie, R.A., Gabriel, T.A., Schwenterly, S.W. et al. Monte Carlo simulation of molecular flow in a neutral beam injector and comparison with experiment. J Fusion Energ 2, 161–172 (1982). https://doi.org/10.1007/BF01054582

Download citation

  • Received:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF01054582

Key words

Navigation