Abstract
Neutron activation analysis, gamma-ray spectrometry, particle sizing and photography of the corrosion products were used to qualify the constructional materials and primary coolants. The investigations related to: characterization of the construction materials of the primary circuit, circulated washing, hot conditioning, physical and energetic start up. The aim of the measurements was to study the cleanness of the primary circuit from assembling up to energetic start up and to follow closely the variation in the amount and the removing of the mechanical contaminants and corrosion products depending on the technological parameters.
Similar content being viewed by others
Reference
A. SIMONITS, L. MOENS, F. de CORTE, A. de WISPELAERE, A. ELEK, J. HOSTE, J. Radioanal. Chem., 60 (1980) 461.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Bogáncs, J., Maróthy, L., Bakos, L. et al. Primary coolant circuit characterization related to starting up the WWER-440 unit. Journal of Radioanalytical and Nuclear Chemistry, Articles 88, 85–96 (1985). https://doi.org/10.1007/BF02037307
Received:
Issue Date: