Abstract
For muon catalyzed fusion (μCF) experiments at RIKEN-RAL muon facility, a tritium gas handling system for a high purity D–T target, free from 3 component, has been constructed to perform precise measurements of α-sticking probability in the μCF cycle. The system has been constructed to enable us to purify the target D–T gas by removing 3He component, to adjust the D/T mixing ratio, and to measure the hydrogen isotope components at the experiment site. The whole performance has been confirmed and a tritium gas with the inventory of 56 TBq (1500 Ci) has been operated in the system.
Similar content being viewed by others
References
K. Nagamine, T. Matsuzaki, K. Ishida et al., Muon Catal. Fusion 1 (1987) 137; 5/6 (1990/1991) 289.
T. Matsuzaki, K. Ishida, K. Nagamine et al., Muon Catal. Fusion 5/6 (1990/1991) 387.
M. Tanase, M. Kato, K. Kurosawa et al., J. Nucl. Sci. Technol. 22 (1988) 147.
W.T. Shmayda, N.P. Kherani, B. Wallace and F. Mazza, Fusion Technol. 21 (1991) 616.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Matsuzaki, T., Nagamine, K., Tanase, M. et al. Tritium gas handling system for muon catalyzed fusion research at RIKEN-RAL muon facility. Hyperfine Interactions 119, 361–363 (1999). https://doi.org/10.1023/A:1012645105677
Issue Date:
DOI: https://doi.org/10.1023/A:1012645105677