Skip to main content
Log in

The potential use of raman mapping to investigate in vitro deposition of combination pressurized metered-dose inhalers

  • Published:
The AAPS Journal Aims and scope Submit manuscript

Abstract

Scanning near-infrared Raman microscopy has been used to map aerosol particulate deposits produced from pressurized metered-dose inhalers (pMDI). A commercially available combination asthma therapy pMDI (Ventide, Allen and Hanbury, UK), containing salbutamol and beclometasone dipropionate, was analyzed by conventional in vitro quantitative analysis and scanning Raman microscopy. Raman maps, taken from Andersen cascade impactor plate stages 3 and 5 (over 100 × 100 μm areas) suggested good correlation with chemical analysis of the respective stages. Scanning Raman microscopy allows visual differentiation between formulation components (not possible using conventional imaging techniques), while potentially allowing chemical quantification.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Clarke FC, Jamieson MJ, Clark DA, Hammond SV, Jee RD, Moffat AC. Chemical image fusion: the synergy of FT-NIR and Raman mapping microscopy to enable a more complete visualization of pharmaceutical formulations.Anal Chem. 2001;73:2213–2220.

    Article  CAS  PubMed  Google Scholar 

  2. Bolton BA, Prasad PN. Laser Raman investigation of drug polymer conjugates—sulfathiazole povidone coprecipitates.J Pharm Sci. 1984;73:1849–1851.

    Article  CAS  PubMed  Google Scholar 

  3. Breitenbach J, Schrof W, Neumann J. Confocal Raman-spectroscopy: analytical approach to solid dispersions and mapping of drugs.Pharm Res. 1999;16:1109–1113.

    Article  CAS  PubMed  Google Scholar 

  4. Armstrong GL, Edwards HGM, Farwell DW, Williams AC. Fourier transform Raman microscopic study of drug distribution in a transdermal drug delivery device.Vib Spectrosc. 1996;11:105–113.

    Article  CAS  Google Scholar 

  5. Clarke MJ, Peart J, Cagnani S, Byron PR. Adhesion of powders for inhalation: An evaluation of drug detachment from surfaces following deposition from aerosol streams.Pharm Res. 2002;19:322–329.

    Article  CAS  PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Paul M. Young.

Additional information

Published: October 29, 2004.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Steele, D.F., Young, P.M., Price, R. et al. The potential use of raman mapping to investigate in vitro deposition of combination pressurized metered-dose inhalers. AAPS J 6, 32 (2004). https://doi.org/10.1208/aapsj060432

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1208/aapsj060432

Keywords

Navigation