Hostname: page-component-76fb5796d-2lccl Total loading time: 0 Render date: 2024-04-25T16:29:18.167Z Has data issue: false hasContentIssue false

Technological Advances in the University of Washington Accelerator Mass Spectrometry System

Published online by Cambridge University Press:  18 July 2016

G W Farwell
Affiliation:
Nuclear Physics Laboratory, University of Washington, Seattle, Washington 98195
P M Grootes
Affiliation:
Nuclear Physics Laboratory, University of Washington, Seattle, Washington 98195
D D Leach
Affiliation:
Nuclear Physics Laboratory, University of Washington, Seattle, Washington 98195
F H Schmidt
Affiliation:
Nuclear Physics Laboratory, University of Washington, Seattle, Washington 98195
Rights & Permissions [Opens in a new window]

Abstract

Core share and HTML view are not available for this content. However, as you have access to this content, a full PDF is available via the ‘Save PDF’ action button.

During the past year we have continued to work toward greater stability and flexibility in nearly all elements of our accelerator mass spectrometry (AMS) system, which is based upon an FN tandem Van de Graaff accelerator, and have carried out measurements of 14C/12C and 10Be/9Be isotopic abundance ratios in natural samples. The principal recent developments and improvements in the accelerator system and in our sample preparation techniques for carbon and beryllium are discussed, and the results of a study of 10Be cross-contamination of beryllium samples in the sputter ion source are presented.

Type
VIII. Technical Aspects of Accelerator Mass Spectrometry
Copyright
Copyright © The American Journal of Science 

References

Farwell, GW, Grootes, PM, and Schmidt, FH, 1981, Accelerator mass spectrometry: cross-contamination in a sputter ion source: Am Phys Soc Bull, v 26, p 1159.Google Scholar
Farwell, GW, Grootes, PM, Leach, DD, Schmidt, FH, and Stuiver, M, 1983, 10Be and 14C measurements with the University of Washington FN tandem accelerator, in : Radiocarbon, v 25.Google Scholar
Farwell, GW, Schmidt, FH, and Grootes, PM, 1981, Accelerator mass spectrometry at the University of Washington, in : Argonne Natl Lab pub ANL/PHY-81-1, p 100119.Google Scholar
Grootes, PM, Stuiver, M, Farwell, GW, Schaad, TP, and Schmidt, FH, 1980, Enrichment of 14C and sample preparation for beta and ion counting, in : Radiocarbon, v 22, no. 2, p 487499.Google Scholar
Grootes, PM, Stuiver, M, Farwell, GW, and Schmidt, FH, 1981, Sample preparation for accelerator mass spectrometry at the University of Washington, in : Argonne Natl Lab pub ANL/PHY-81-1, p 405415.Google Scholar
Schmidt, FH and Fauska, H, 1982, Auto-control of injected beams in accelerator mass spectrometry (AMS): Am Phys Soc Bull, v 27, p 526.Google Scholar