Brought to you by:
PLASMA TECHNOLOGY

Study on Performance Parameters of the Plasma Source for a Short-Conduction-Time Plasma Opening Switch

, , , , , and

Published under licence by IOP Publishing Ltd
, , Citation Luo Weixi et al 2012 Plasma Sci. Technol. 14 1116 DOI 10.1088/1009-0630/14/12/15

1009-0630/14/12/1116

Abstract

Plasma source performance parameters, including plasma ejection density and velocity, greatly affect the operation of a short-conduction-time plasma opening switch (POS). In this paper, the plasma source used in the POS of Qiangguang I generator is chosen as the study object. At first the POS working process is analyzed. The result shows that the opening performance of the POS can be improved by increasing the plasma ejection velocity and decreasing the plasma density. The influence of the cable plasma gun structure and number on the plasma ejection parameters is experimentally investigated with two charge collectors. Finally a semi-empirical model is proposed to describe the experimental phenomenon.

Export citation and abstract BibTeX RIS

Please wait… references are loading.
10.1088/1009-0630/14/12/15