ExLibris header image
SFX Logo
Title: Intensity modulated proton therapy and its sensitivity to treatment uncertainties 2: the potential effects of inter-fraction and inter-field motions
Source:

Physics in Medicine and Biology [0031-9155] Lomax, A J yr:2008


Collapse list of basic services Basic
Full text
Full text available via EZB-NALIM-00482 IOP Archive NL
GO
Document delivery
Request document via Library/Bibliothek GO
Users interested in this article also expressed an interest in the following:
1. A J Lomax;, A J J. "Intensity modulated proton therapy and its sensitivity to treatment uncertainties 1: the potential effects of calculational uncertainties." Physics in medicine & biology 53.4 (2008): 1027-42. Link to Full Text for this item Link to SFX for this item
2. D Pflugfelder; J J Wilkens; U Oelfke;, U. "Worst case optimization: a method to account for uncertainties in the optimization of intensity modulated proton therapy." Physics in medicine & biology 53.6 (2008): 1689-700. Link to Full Text for this item Link to SFX for this item
3. Dendale, R. "Proton beam radiotherapy for uveal melanoma: results of Curie Institut-Orsay proton therapy center (ICPO)." International journal of radiation oncology, biology, physics 65.3 (2006): 780-7. Link to SFX for this item
4. Moravek, Z. "Uncertainty reduction in intensity modulated proton therapy by inverse Monte Carlo treatment planning." Physics in medicine and biology 54.15 (2009): 4803-4819. Link to Full Text for this item Link to SFX for this item
5. Schaffner, B. "The precision of proton range calculations in proton radiotherapy treatment planning: experimental verification of the relation between CT-HU and proton stopping power." Physics in medicine & biology 43.6 (1998): 1579-92. Link to Full Text for this item Link to SFX for this item
6. Bortfeld, T. "Accounting for range uncertainties in the optimization of intensity modulated proton therapy." Physics in medicine & biology 52.10 (2007): 2755-73. Link to Full Text for this item Link to SFX for this item
7. Schneider, U. "The calibration of CT Hounsfield units for radiotherapy treatment planning." Physics in medicine & biology 41.1 (1996): 111-124. Link to Full Text for this item Link to SFX for this item
8. Thomas, S. "Margins for treatment planning of proton therapy." Physics in medicine & biology 51.6: 1491-1501. Link to SFX for this item
9. Soukup, M. "Reducing the sensitivity of IMPT treatment plans to setup errors and range uncertainties via probabilistic treatment planning." Medical physics 36.1 (2009): 149-163. Link to SFX for this item
10. Schneider, W. "Correlation between CT numbers and tissue parameters needed for Monte Carlo simulations of clinical dose distributions." Physics in medicine & biology 45.2: 459-478. Link to SFX for this item
11. Purdie, Thomas G. "Robust optimization methods for cardiac sparing in tangential breast IMRT." Medical physics 42.5 (2015): 2212-2222. Link to SFX for this item
12. Sahoo, N. "A Novel Procedure to Account for the Changes in the Position of High or Low Density Objects in Treatment Planning for Spot Scanned Proton Beam Therapy." International journal of radiation oncology, biology, physics 78.3 (2010). Link to SFX for this item
13. Paganetti, H. "Range uncertainties in proton therapy and the role of Monte Carlo simulations." Physics in medicine and biology 57.11 (2012): -117. Link to Full Text for this item Link to SFX for this item
14. Fitzek, M. "Letter by M. Fitzek on Höcht S, Bechrakis NE, Nausner M, et al. Proton therapy of uveal melanomas in Berlin: 5 years of experience at the Hahn-Meitner Institut: in: Strahlenther Onkol 2004;180:419-24 (No. 7) (DOI 10.1007/s00066-004-1222-5)." Strahlentherapie und Onkologie (2007). Link to Full Text for this item Link to SFX for this item
15. Conway, Antony M. "Estimates of Ocular and Visual Retention Following Treatment of Extra-Large Uveal Melanomas by Proton Beam Radiotherapy." Archives of ophthalmology 124.6 (2006): 838-843. Link to SFX for this item
16. Bansal, R. "A minimax entropy registration framework for patient setup verification in radiotherapy." Computer aided surgery 4.6: 287-304. Link to SFX for this item
17. Verschueren, Karijn M.S M. "Long-term outcomes of eye-conserving treatment with Ruthenium106 brachytherapy for choroidal melanoma." Radiotherapy and oncology 95.3 (2010): 332-338. Link to SFX for this item
18. Widesott, L. "Intensity-modulated proton therapy versus helical tomotherapy in nasopharynx cancer: planning comparison and NTCP evaluation." International journal of radiation oncology, biology, physics 72.2 (2008): 589-96. Link to SFX for this item
19. Constantinou, C. "An electron density calibration phantom for CT-based treatment planning computers." Medical physics 19.2 (1992): 325-7. Link to SFX for this item
20. Schaffner, B. "Proton dose calculation based on in-air fluence measurements." Physics in medicine & biology 53.6 (2008): 1545-1562. Link to Full Text for this item Link to SFX for this item
View More...
View Less...
Select All Clear All

Expand list of advanced services Advanced