Test results of the threshold aerogel Cherenkov counter system with n = 1.05 using electrons and muons at p < 500 MeV/c

, , , , , , , , , , , and

Published 20 August 2014 © 2014 IOP Publishing Ltd and Sissa Medialab srl
, , Citation A Yu Barnyakov et al 2014 JINST 9 C08010 DOI 10.1088/1748-0221/9/08/C08010

1748-0221/9/08/C08010

Abstract

Test results of the threshold aerogel Cherenkov counter system with n=1.05 intended for particle separation are presented. The system is constructed for SND detector which is taking data at VEPP-2000 e+e collider. The measurements have been done using particles from e+ee+e and e+e→μ+μ reactions. The average signal from electrons is 3.5 photoelectrons.