ExLibris header image
SFX Logo
Title: Compartmental Modeling of Transdermal Iontophoretic Transport: I. In Vitro Model Derivation and Application
Source:

Pharmaceutical Research [0724-8741] Nugroho, Akhmad yr:2004


Collapse list of basic services Basic
Full text
Full text available via SpringerLINK Contemporary 1997-Present
GO
Document delivery
Request document via Library/Bibliothek GO
Users interested in this article also expressed an interest in the following:
1. Rao, G. "Reverse iontophoresis: Noninvasive glucose monitoring in vivo in humans." Pharmaceutical Research 12.12 (1995): 1869-1873. Link to Full Text for this item Link to SFX for this item
2. Stagni G, D. "Intradermal microdialysis: kinetics of iontophoretically delivered propranolol in forearm dermis." Journal of controlled release 63.3 (2000): 331-9. Link to Full Text for this item Link to SFX for this item
3. Yan, G. "Quantitative study of electrophoretic and electroosmotic enhancement during alternating current iontophoresis across synthetic membranes." Journal of pharmaceutical sciences 93.12 (2004): 2895-2908. Link to Full Text for this item Link to SFX for this item
4. Charman, William N N. "Drug delivery: A key factor in realising the full therapeutic potential of drugs." Drug development research 46.3-4 (1999): 316-327. Link to Full Text for this item Link to SFX for this item
5. Henderson, Theodore A. "Near-infrared photonic energy penetration: can infrared phototherapy effectively reach the human brain?" Neuropsychiatric Disease and Treatment 11.default (2015): 2191-2208. Link to Full Text for this item Link to SFX for this item
6. Siddoju, S. "Acyclovir skin depot characterization following in vivo iontophoretic delivery." Skin research and technology 17.2 (2011): 234-244. Link to Full Text for this item Link to SFX for this item
7. Glikfeld, P. "Noninvasive sampling of biological fluids by iontophoresis." Pharmaceutical Research 6.11 (1989): 988-90. Link to Full Text for this item Link to SFX for this item
8. ALLO, S. "INSULIN-RESISTANCE AND MECHANICAL DYSFUNCTION IN HEARTS OF WISTAR RATS WITH STREPTOZOTOCIN-INDUCED NON-INSULIN-DEPENDENT DIABETES-MELLITUS - REPLY." Diabetologia 36.9 (1993): 880-881. Link to Full Text for this item Link to SFX for this item
9. Urquhart, J. "Controlled drug delivery: therapeutic and pharmacological aspects." Journal of internal medicine 248.5 (2000): 357-376. Link to Full Text for this item Link to SFX for this item
10. Imanidis, G. "An extended model based on the modified Nernst-Planck equation for describing transdermal iontophoresis of weak electrolytes." Journal of pharmaceutical sciences 95.7 (2006): 1434-1447. Link to Full Text for this item Link to SFX for this item
11. Liu, Nanguo G. "Photoregulation of mass transport through a photoresponsive azobenzene-modified nanoporous membrane." Nano letters 4.4 (2004): 551-554. Link to Full Text for this item Link to SFX for this item
12. RAO, G. "REVERSE IONTOPHORESIS - DEVELOPMENT OF A NONINVASIVE APPROACH FOR GLUCOSE MONITORING." Pharmaceutical Research 10.12 (1993): 1751-1755. Link to Full Text for this item Link to SFX for this item
13. Tierney, M.J. J. "Clinical evaluation of the GlucoWatch (R) biographer: a continual, non-invasive glucose monitor for patients with diabetes." Biosensors & bioelectronics 16.9-12 (2001): 621-629. Link to Full Text for this item Link to SFX for this item
14. Muller-Goymann, C. C. "Physicochemical characterization of colloidal drug delivery systems such as reverse micelles, vesicles, liquid crystals and nanoparticles for topical administration." European journal of pharmaceutics and biopharmaceutics 58.2 (2004): 343-356. Link to SFX for this item
15. Stayton P S, P S S. "Molecular engineering of proteins and polymers for targeting and intracellular delivery of therapeutics." Journal of Controlled Release 65.1 (2000): 203-20. Link to Full Text for this item Link to SFX for this item
16. Watanabe, T. "Photoresponsive hydrogel microstructure fabricated by two-photon initiated polymerization." Advanced functional materials 12.9 (2002): 611-614. Link to Full Text for this item Link to SFX for this item
17. Ching, C. "Reverse iontophoresis: A non-invasive technique for measuring blood lactate level." Sensors and actuators. B, Chemical 129.1 (2008): 352-358. Link to SFX for this item
18. Hu, J. "The evolution of commercialized glucose sensors in China." Biosensors & bioelectronics 24.5 (2009): 1083-1089. Link to SFX for this item
19. Murthy, N. "The design and synthesis of polymers for eukaryotic membrane disruption." Journal of Controlled Release 61.1 (1999): 137-143. Link to Full Text for this item Link to SFX for this item
20. Palioura, D. "Metal Nanocrystals Incorporated within pH-Responsive Microgel Particles." Langmuir 23.10 (2007): 5761-5768. Link to Full Text for this item Link to SFX for this item
View More...
View Less...
Select All Clear All

Expand list of advanced services Advanced