Abstract
The ultimate bearing capacity of two closely spaced strip footings, placed on a cohesionless medium and loaded simultaneously to failure at the same magnitude of failure load, was determined by using an upper bound limit analysis. A logarithmic spiral radial shear zone, comprising of a number of triangular rigid blocks, was assumed to exist around each footing edge. The equations of the logarithmic spiral arcs were based on angles φL and φR rather than soil friction angle φ; the values of φL and φR were gradually varied in between 0 and φ. The ultimate bearing capacity was found to become maximum corresponding to a certain critical spacing between the footings. For spacing greater than the critical, the bearing capacity was found to decrease continuously with increase in the spacing. The extent of the spacing corresponding to which the ultimate bearing capacity becomes either maximum or equal to that of a single isolated footing increases with increase in φ. The results compare reasonably well with the available theoretical and experimental data.
Similar content being viewed by others
References
Anderheggen E, Knöpfel H (1972) Finite element limit analysis using linear programming. Int J Solid Struct 8:1413–1431
Chen WF (1975) Limit analysis and soil plasticity. Elsevier, Amsterdam
Das BM, Larbi-Cherif S (1983) Bearing capacity of two closely-spaced shallow foundations on sand. Soils Found 23(1):1–7
Frydman S, Burd HJ (1997) Numerical studies of bearing capacity factor N γ. J Geotechnical Geoenviron Eng ASCE 123(1):20–29
Graham J, Raymond GP, Suppiah A (1984) Bearing capacity of three closely-spaced footings on sand. Géotechnique 34(2):173–182
Kumar J (2004) Effect of footing-soil interface friction on bearing capacity factor N γ. Géotechnique 54(10):677–680
Kumar A, Saran S (2003) Closely spaced footings on geogrid-reinforced sand. J Geotechnical Geoenviron Eng ASCE 129(7):660–664
Michalowski RL (1997) An estimate of the influence of soil weight on bearing capacity using limit analysis. Soils Found 37(4):57–64
Saran S, Agarwal VC (1974) Interference of surface footings on sand. Indian Geotechnical J 4(2):129–139
Sloan SW (1989) Upper bound limit analysis using finite elements and linear programming. Int J Numer Anal Methods Geomechanics 13:263–282
Soubra AH (1999) Upper-bound solutions for bearing capacity of foundations. J Geotechnical Geoenviron Eng ASCE 125(1):59–68
Stuart JG (1962) Interference between foundations, with special reference to surface footings in sand. Géotechnique 12(1):15–22
Terzaghi K (1943) Theoretical soil mechanics. Wiley, New York
West JM, Stuart JG (1965) Oblique loading resulting from interference between surface footings on sand. Proceedings of the 6th international conference on soil mechanics and foundation engineering, Montreal, vol. 2, pp. 214–217
Zhu D (2000) The least upper-bound solutions for bearing capacity factor N γ. Soils Found 40(1):123–129
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Kumar, J., Ghosh, P. Upper bound limit analysis for finding interference effect of two nearby strip footings on sand. Geotech Geol Eng 25, 499–507 (2007). https://doi.org/10.1007/s10706-007-9124-9
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10706-007-9124-9