Abstract

This paper describes a new two-stage robust Newton-type numerical algorithm for power quality assessment in electric power systems. In order to estimate current and voltage spectra simultaneously with the fundamental frequency in the first algorithm stage, the robust Newton-type algorithm is applied. In the second algorithm stage, power quality indicators are calculated. Particularly the active, reactive, apparent and distortion powers are determined. As the main advantage, the technique provides estimates that are insensitive to frequency deviations and bad data, which often appear as a consequence of communication error, incomplete measurement, errors in mathematical models, etc. The algorithm performance is tested under laboratory conditions using the distorted voltage and current signals digitized during an AC-motor start.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7
Fig. 8
Fig. 9
Fig. 10
Fig. 11
Fig. 12
Fig. 13

Similar content being viewed by others

References

  1. Dugan RC (1996) Electrical power systems quality. McGraw-Hill, New York

  2. Budeanu CI (1927) Puissances reactives at fictives. Institut Romain de l’Energie, Publ. 2, Bucharest, Romania

  3. Fryze S (1931) Active, reactive and apparent power in non-sinusoidal systems. Przegled Elektrotek, No. 7, pp 193–203

  4. Kusters HL, Moore WJM (1980) On the definition of reactive power under non-sinusoidal conditions. IEEE Trans Power Apparatus Syst 99:1845–1854

    Google Scholar 

  5. Shepherd W, Zakikhani P (1972) Suggested definition of reactive power for non-sinusoidal systems IEE Proc 119:1361–1362

    Google Scholar 

  6. Test Laboratories Int (1996) DFR AssistantTM product description

  7. Skokljev I, Kovacevic B, Terzija V (1999) Power system steady-state estimation M-robust approach with measurement applications ETEP 9(4)

  8. Terzija V, et al. (1994) Voltage phasor and local system frequency estimation using newton type algorithm. IEEE Trans Power Deliv 9(3):1368–1374

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Vladimir V. Terzija.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Terzija, V.V., Stanojevic, V. Power quality indices estimation using robust estimation approach. Electr Eng 87, 173–179 (2005). https://doi.org/10.1007/s00202-004-0234-6

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00202-004-0234-6

Keywords

Navigation