Aerodynamic characteristics of anemometer cupsThe static lift and drag forces on three hemispherical and two conical cups were measured over a range of angles of attack from 0 degrees to 180 degrees and a range of Reynolds Numbers from very small up to 400,000. The problems of supporting the cup for measurement and the effect of turbulence were also studied. The results were compared with those of other investigators.