Measurements of low radioactive contaminations in lead using bolometric detectors

https://doi.org/10.1016/0168-583X(93)95884-8Get rights and content

Abstract

Bolometric detectors made with samples of crystalline and polycrystalline lead have been operated to measure their internal radioactivity due to 210Pb. It has been found that contaminations of hundreds of becquerels per kilogram are present in commercial low radioactivity lead and that these contaminations can be reduced by an order of magnitude by crystallisation. A low activity of a few hundreds of millibecquerels per kilogram still persists in specially prepared low radioactivity lead. No evidence for contamination is on the contrary found in a 2000 year old lead sample from a sunk Roman ship, at a level of less than 20 millibecquerel per kilogram.

References (31)

  • V. Narayanamurti et al.

    Phys. Rev.

    (1978)
  • T. Tomoda

    Rep. Prog. Phys.

    (1991)
    M.K. Moe

    Nucl. Phys. B

    (1991)
    E. Fiorini

    Nucl. Phys. News

    (1991)
    H.V. Klapdor

    J. Phys. G: Nucl. Part. Phys.

    (1991)
  • P.F. Smith et al.

    Phys. Rep.

    (1990)
  • D. Earle

    Measurements of Th and U in acrylic at the ppt level

  • I. Ward

    Analysis of sub-ppb radioactive species in metals by glow discharge techniques

  • Cited by (22)

    • The role of underwater cultural heritage on dark matter searches: Ancient lead, a dual perspective

      2015, Ocean and Coastal Management
      Citation Excerpt :

      In fact, lead manufactured post 1945 may contain radioactive products due to nuclear weapon testing in the atmosphere (Smith et al., 2008). Low-activity “ores” can provide a reasonable high quality lead that combined with optimized process production can yield alpha emission rates as low as 260 mBq/kg (Johnson&Mathey's) (Alessandrello et al., 1993). As an example, J&M lead was used in the Heidelberg–Moscow experiment (Klapdor-Kleingrothaus et al., 2001).

    • A new natural gamma radiation measurement system for marine sediment and rock analysis

      2011, Journal of Applied Geophysics
      Citation Excerpt :

      Monte Carlo simulations show that a lead shield thickness of 8 cm around each NaI detector will decrease ~ 1.5 MeV gamma rays generated by the ship's steel about 100 times. Common virgin lead is internally radioactive in the order of at least 150–250 Bq/kg due to contamination of beta active 210Pb isotope (Alessandrello et al., 1991, 1993) and contributes to the gamma ray background above 100 keV. For the traditional experimental systems, where cosmic radiation dominates the background continuum, the contribution from virgin lead radioactivity can usually be neglected.

    • Ancient Greek lead findings in Ukraine

      2009, Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
    • Measurements of internal radioactive contamination in samples of Roman lead to be used in experiments on rare events

      1998, Nuclear Instruments and Methods in Physics Research, Section B: Beam Interactions with Materials and Atoms
    • The bolometers as nuclear recoil detectors

      1998, Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
    View all citing articles on Scopus