Summary
There are a number of parameters which have to be chosen depending on the analysis being done in gas chromatography. While the choice of stationary phase material is based on the solutes to be separated, the thickness is dependent on the concentration and the volatility of the components to be analyzed. This study undertakes a coupled column phase ratio optimization by connecting a short piece of a particular column prior to a normal length of an analytical column. Various columns of different dimensions (phase ratio), but of the same stationary phase material (methyl silicone), are coupled together by a deactivated glass press-fit connector, and the efficiency and capacity are measured. The coupling of fused silica open tubular columns is optimized in efficiency by matching or decreasing the phase ratio of successive columns. Capacity optimization is accomplished by increasing the phase ratio of consecutive columns. Capacity and efficiency optimization are opposing each other; therefore, if some efficiency can be sacrificed a substantial increase in capacity is possible.
Similar content being viewed by others
References
T. C. Gerbino, G. Castello, J. High Resolut. Chromatogr.,15(7), 428 (1992).
B. Larsen, S. Bowadt, S. Facchetti, Int. J. Environ. Anal. Chem.47(3), 147 (1992).
E. Benicka, J. Krupcik, D. Repka, P. Sandra, Chromatographia,33(9–10), 463 (1992).
L. Castellani, G. Goretti, B. Neri, M. V. Russo, P. Zacchei, Ann. Chim.,82(3–4), 137 (1992).
P. Clair, M. Tua, H. Simian, J. High Resolut. Chromatogr.,14(6), 383 (1991).
G. E. Platoff, D. W. Hill, T. R. Koch, Y. H. Hale, J. Anal. Toxicol.,16(6), 389 (1992).
W. Engewald, R. Reinhardt, A. Steinborn, J. Rohloff, R. Herzschuh, Chromatographia34(5–8), 253 (1992).
S. Boewadt, B. Larsen, J. High Resolut. Chromatogr.,15(6), 377 (1992).
R. J. Laub, J. H. Purnell, J. Chromatogr.,112, 71 (1975).
D. F. Ingraham, C. F. Shoemaker, W. Jennings, J. Chromatogr.,239, 39 (1982).
J. Krupcik, J. Mocak, A. Simova, J. Garaj, J. Chromatogr.,238, 1 (1982).
M. F. Mehran, W. J. Cooper, W. Jennings, HRC & CC7, 215 (1984).
G. Schomburg, H. Husmann, E. Hubinger, W. A. Konig, HRC & CC7, 404 (1984).
R. E. Kaiser, R. I. Rieder, HRC & CC2, 416 (1979).
R. E. Kaiser, R. I. Rieder, L. Leming, L. Blomberg, P. Kusz, HRC & CC8, 580 (1985).
K. Grob, Jr., J. Chromatogr.,237, 15 (1982).
G. Guiochon, J. E. N. Gutierrez, J. Chromatogr.,406, 3 (1987).
V. Pretorius, K. Lawson, HRC & CC9, 278 (1986).
E. F. Barry, K. P. Li, C. Merritt, Jr., J. Chrom. Sci.,20, 357 (1982).
W. Jennings, “Analytical Gas Chromatography”, Academic Press, Orlando, FL, 1987; p. 15.
J. P. Foley, J. G. Dorsey, Anal. Chem.,55, 730 (1983).
B. A. Bidlingmeyer, F. V. Warren, Jr., Anal. Chem.,56, 1583A (1984).
J. R. Conder, HRC & CC5, 341 (1982).
K. Grob, B. Schilling, J. Chromatogr.,391, 3 (1987).
K. Grob, Jr., G. Grob, K. Grob, J. Chromatogr.,156, 1 (1978).
G. Takeoka, W. Jennings J. Chrom. Sci.,22, 177 (1984).
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Murphy, R.E., Heath, R.R. & Dorsey, J.G. The optimization of capacity and efficiency when coupling fused silica open tubular columns in gas chromatography. Chromatographia 37, 65–72 (1993). https://doi.org/10.1007/BF02272191
Received:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF02272191