Skip to main content
Log in

Zusammenfassung

Robuste Taucherwaagen von geringem „Reduzierten Gewicht“ lassen sich leicht herstellen, wenn als Material für den Plastikkopf statt Polystyrol (Dichte 1,05) das spezifisch leichtere Polyäthylen (Dichte 0,92) verwendet wird.

Sowohl das Reduzierte Gewicht als auch das Volumen begrenzen die Empfindlichkeit der Taucherwaage.

Summary

The use of polyethylene (density 0.92) instead of polystyrene (density 1.05) as cap material permits the easy construction of relatively strong diver balances of small “Reduced Weight”.

Both Reduced Weight and volume limit the sensitivity of the diver balance.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Literatur

  • Gellenkirchen, W.L.M., andE. Zeuthen: Changes in submerged (reduced) weight assoziated with cell division in Echinoderm eggs. A study with the Cartesian diver balance. C. R. Lab. Carlsberg, Sér. chim. (im Druck).

  • Holter, H.: Technique of the Cartesian diver. C. R. Lab. Carlsberg, Sér. chim.24, 399–478 (1943).

    Google Scholar 

  • Linderstrøm-Lang, K.: Principle of the Cartesian diver applied to gasometric technique. Nature (Lond.)140, 108 (1937).

    Google Scholar 

  • On the theory of the Cartesian diver micro-respirometer. C. R. Lab. Carlsberg, Sér. chim.24, 333–398 (1943).

    Google Scholar 

  • Linderstrøm-Lang, K., andD. Glick: Micromethod for determination of choline esterase activity. C. R. Lab. Carlsberg, Sér. chim.22, 300–306 (1938).

    Google Scholar 

  • Linderstrøm-Lang, K., andH. Lanz: Studies on enzymatic histochemistry. XXIX. Dilatometric micro-estimation of peptidase activity. C. R. Lab. Carlsberg, Sér. chim.21, 315–338 (1938).

    Google Scholar 

  • Løvtrup, S.: Observations on the Cartesian diver balance technique. C. R. Lab. Carlsberg, Sér. chim.27, 125–136 (1950).

    Google Scholar 

  • Prescott, D. M., andD. Mazia: The permeability of nucleated and enucleated fragments ofAmoeba proteus to D2O. Exp. Cell Res.6, 117–126 (1954).

    Google Scholar 

  • Zeuthen, E.: A Cartesian diver balance weighing reduced weights (R.W.) with an accuracy of ± 0.01 γ. C. R. Lab. Carlsberg, Sér. chim.26, 243–266 (1948).

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Additional information

Mit 1 Textabbildung

Mit Unterstützung der Deutschen Forschungsgemeinschaft und des Rask-Ørsted-Fonds.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Hagens, HW. Eine Polyäthylen-Glas-Taucherwaage. Histochemie 1, 109–112 (1958). https://doi.org/10.1007/BF00770278

Download citation

  • Received:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00770278

Navigation