Skip to main content
Log in

Internal calibration device for the infrared imager of ISO

  • Published:
Experimental Astronomy Aims and scope Submit manuscript

Abstract

The imager of the infrared satellite ISO will allow spectral imaging under very low flux conditions in the two to-eighteen-microns range, close to the fundamental limit of the zodiacal background photon noise. To optimize the performance of the imager, we must use an internal calibration device, mainly to track changes in the responsivity of the pixels of the detectors arrays, the limit of detection greatly depending upon the quality of the flat field corrections in certain cases.

The first section introduces ISO and its infrared imager and emphasizes the necessity of in-flight calibration. The following chapter presents the specifications for the internal calibration device. The chosen design for the flight model which consists of an infrared emitter and two integrating spheres, is presented in the third chapter. The last part describes the cryogenic bench dedicated to relative photometric tests, the absolute calibration is made in the camera. Endly we present the results obtained with this facility and final tests to achieve the qualification of the device.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Ballard, S. S., Mc Carthy, K. A., Wolfe, W. L.: Optical Materials for Infrared Instrumentation, The University of Michigan (1959).

  • Bernel, J.: Rapport d'Essais Technologiques sur les Liaisons Souples a Usage Spatial, C.N.E.S., 77–66 (1977).

  • Césarsky, C. J.: ISOCAM, in Infrared Astronomy with ISO, edited by T. Encrenaz and M. F. Kessler, Nove Science Publishers, 1992.

  • Denner, H. D.: Electrical Insulators at Low Temperatures, ESTEC -University of Berlin (1986).

  • Epstein, G., Carpentier, Y., Lorans, D., Stefanovitch, D., Tiphène, D.: Near Infrared Focal Plane for the Infrared Space Observatory Camera, Proceedings of SPIE, Vol. 865 (1987).

  • Goebel, D. G.: Generalized Integrating Sphere Theory, Appl. Optics, Vol. 6, p. 125 (1967). ISOCAM

    Google Scholar 

  • Jacquez, J. A., Kuppenheim, H. F.: Theory of the Integrating Sphere, J. Opt. Soc. Am., Vol. 45-6, p. 460 (1955).

    Google Scholar 

  • Kessler, M. F., Heske, A., Metcalfe, L., Salama, A.: The ISO Mission - A Scientific Overview, ESA Bulletin 67 (1991).

  • Lucas, C, Maillart, P., Mottier, P., Pantigny, P., Vilain, M.: Development of an Infrared Detector Array for Infrared Space Observatory Camera, Proceedings of SPIE, Vol. 865 (1987).

  • Saint-Pé, O.: Etude, Réalisation, Mise au point et Caract érisation du Dispositif d'Etalonnage Interne de la Caméra IR du Satellite ISO, These en Sciences Physiques, Paris XI (1990).

  • Wolfe, W. L., Zissis, G. J.: The Infrared Handbook, Office of Naval Research, Department of the Navy (1985).

  • Ximénez de Ferrán, S.: The ISO Spacecraft, ESA Bulletin 67 (1991).

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

SAINT-PÉ, O., PUGET, P., ROUAN, D. et al. Internal calibration device for the infrared imager of ISO. Exp Astron 4, 195–211 (1994). https://doi.org/10.1007/BF01580782

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF01580782

Keywords

Navigation