Abstract
Polymethylmethacrylate (PMMA) bone cements present various problems with respect to biocompatibility and stability. In order to study the histological changes at the bone-cement interface following total hip replacement, a small animal model was created by implanting hip prostheses using two different bone cements (PMMA and glass-ionomer cement, GIC). Two problems with the use of GIC for fixation of the prosthesis became evident. One year following implantation, histomorphometric analysis of femurs containing the GIC demonstrated significantly higher amounts of osteoid at the bone-cement interface. This disturbance of mineralization is comparable with osteomalacia and probably due to leaching of aluminum ions. In addition the mechanical properties of GIC proved to be inadequate for the loads placed upon it in this hip replacement model.
Similar content being viewed by others
References
K. L. MARKOLF and H. C. AMSTUTZ,Clin. Orthop. 121 (1976) 99.
L. LIDGREN, H. DRAR and J. MÖLLER,Acta Orthop. Scand. 55 (1984) 536.
D. W. BURKE, E. I. GATES and W. H. HARRIS,J. Bone Jt. Surg. 66-A (1984) 1265.
R. M. PILLIAR, R. BLACKWELL, I. MACNAB, and H. U. CAMERON,J. Biomed. Mater. Res. 10 (1976) 893.
B. POURDEYHEMI and H. D. WAGNER, ibid.23 (1989) 63.
A. M. RIJKE and M. R. RIEGER, ibid.11 (1977) 373.
P. J. VAN MULLEM and J. R. DE WIJN,J. Cranio-Max.-Fac. Surg. 16 (1988) 99.
K. R. DAI, Y. K. LIU, J. B. PARK and C. R. CLARK,J. Biomed. Mater. Res. 25 (1991) 141.
W. HENNIG and B. A. BLENCKE, H. BRÖMER, K. K. DEUTSCHER, A. GROSS, and W. EGE, ibid.13 (1979) 89.
H. MITTELMEIER, U. HANSER and J. HARMS,Z. ORTHOP. 118 (1980) 658.
M. P. PATEL, M. BRADEN and K. W. M. DAVY,Biomaterials 8 (1987) 53.
L. NIMB, J. STÜRUP and J. S. JENSEN,J. Biomed. Mater. Res. 27 (1993) 565.
A. D. WILSON and J. W. McLEAN, in “Glass-ionomer cements” (Quintessence Pub. Co. Chicago, IL, 1988) pp. 13–126.
D. WOOD and R. HILL,Biomaterials 12 (1991) 164.
L. M. JONCK, C. J. GROBBELAAR and H. STRATING,Clin. Mater. 4 (1989) 85.
L. M. JONCK and C. J. GROBBELAAR, ibid.6 (1990) 323.
F. L. RADIN, C. T. RUBIN, E. L. THRASHER, L. E. LANYON, A. M. CRUGNOLA, A. S. SCHILLER, I. L. PAUL, and R. M. ROSE,J. Bone Jt. Surg. 64-A (1982) 1188.
M. SPECTOR, S. SHORTKROFF, H. P. HSU, N. LANE, C. B. SLEDGE and T. S. THORNHILL,Clin. Orthop. 261 (1990) 140.
U. M. GROSS and V. STRUNZ,Stain Technol. 52 (1977) 217.
H. RINECKER,Acta Orthop. Traumat. Surg. 97 (1980) 263.
N. EFTEKHAR,Clin. Orthop. 81 (1971) 93.
R. D. BECKENBAUGH and D. M. ILSTRUP,J. Bone Jt. Surg. 60-A (1978) 306.
R. FEITH,Acta Orthop. Scand., Suppl.161 (1975).
K. DRAENERT and J. RUDIGIER,Chirurg 49 (1978) 276.
H.-G. WILLERT, J. LUDWIG and M. SEMLITSCH,J. Bone Jt. Surg. 56-A (1974) 1368.
H.-G. WILLERT, in “Implant bone interface”, edited by J. Older (Springer Verlag, Berlin-Heidelberg-New York, 1990) pp. 27–34.
L. NEUMANN and B. J. JENSEN,Acta Orthop. Scand. 60 (1989) 361.
T. ALBREKTSSON and C. JOHANSSON, in “The bone-biomaterial interface”, edited by J. E. Davies (University of Toronto Press, Toronto-Buffalo-London, 1991) pp. 357–363.
O. LANGER and H.-J. SCHMITZ, in Workshop Transactions, Fourth World Biomaterials Congress, Berlin, April 1992, WX 7.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Erbe, M., van Dyck-Erbe, R.L. & Schmitz, H.J. Comparison of a polymethylmethacrylate and glass-ionomer bone cement using a hemiarthroplasty in the rabbit femur. J Mater Sci: Mater Med 7, 517–522 (1996). https://doi.org/10.1007/BF00705435
Received:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF00705435