A study of CTD cables and lowering systems

Thumbnail Image
Date
1979-12
Authors
Berteaux, Henri O.
Walden, Robert G.
Moller, Donald A.
Agrawal, Yogesh C.
Linked Authors
Alternative Title
As Published
Date Created
Location
DOI
10.1575/1912/6365
Related Materials
Replaces
Replaced By
Keywords
Cables
Fiber optics
Abstract
This study first reviews both the electrical and mechanical modes and causes of failure of electromechanical (E/M) cables used to lower deep sea sensors, such as CTD instruments, from oceanographic ships. It then outlines measures or steps that could be taken to correct some of the deficiencies observed and improve the systems presently used. These measures include quality control, tests, operational limits, improved handling and maintenance, improved machinery. The study then surveys alternative cables for lowering the sensors and convey the information from the sensors back to the ship. These alternatives include strength members other than steel (Kevlar)and signal carriers other than conventional copper conductors (fiber optics). The final section - Conclusions - summarizes the recommendations, based on this study, for improving the reliability of present and future CTD lowering systems.
Description
Embargo Date
Citation
Berteaux, H. O., Walden, R. G., Moller, D. A., & Agrawal, Y. C. (1979). A study of CTD cables and lowering systems. Woods Hole Oceanographic Institution. https://doi.org/10.1575/1912/6365
Cruises
Cruise ID
Cruise DOI
Vessel Name