Skip to main content
Log in

Bacillus stearothermophilus spores on strips. Calibration of thermoresistance kinetics to prior biological validation

  • Biotechnology
  • Original Paper
  • Published:
Applied Microbiology and Biotechnology Aims and scope Submit manuscript

Abstract

Filter-paper strips saturated with Bacillus stearothermophilus spores were prepared and then stored for up to 1470 days. The strips were used to measures spore activation time and death kinetics in two systems: a serum bottle/oil bath combination, and glassine packages in a gravity autoclave. The data collected were analyzed primarily by analysis of variance and the interaction of spore storage time, processing temperature, inertial time and exposure time was determined.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Anastasio P, Gella B, Burinato C, Carazzone M, Ciffo F, Genova R, Giglioli N, Malesani L, Veronese M (1986) Controllo ed impiego degli indicatori biologici di sterilizzatione a vapore nella convalida dei processi e nei cicli produttivi. Boll Chim Farm 2:52–61

    Google Scholar 

  • Box GEP, Hunter WG, Hunter JS (1978) Statistics for experiments. Wiley, New York, p 163–244

    Google Scholar 

  • David JRD, Merson RL (1990) Kinetics parameters for inactivation of Bacillus stearothermophilus at high temperature. J Food Sci 55:488–493

    Google Scholar 

  • Drapper NR, Smith H (1981) Applied regression analysis, 2nd edn. Wiley, New York, p 424–457

    Google Scholar 

  • Graham GS, Boris CA (1993) Chemical and biological indicators. In: Morrissey RF, Phillips GB (eds) Sterilization technology. Van Nostrand, New York, p 36

    Google Scholar 

  • Nash RA (1985) A method for calculating thermal sterilization conditions based upon process paramethics. J Parenter Sci Technol 39:241–255

    Google Scholar 

  • Pflug IJ (1996) Discussion of the z-value to use in calculating the Fo-value for high-temperature sterilization processes. J Pharm Sci Technol 50:51–54

    Google Scholar 

  • Reich RR (1981) Bacillus stearothermophilus spore suspension. Effect of storage conditions and time on viability and moist heat resistance. J Parenter Sci Technol 35:74–78

    Google Scholar 

  • USP XXII (1990) The United States Pharmacopoeia, 22nd edn. Rev Mack, Easton, pp 1705–1706

    Google Scholar 

  • Vessoni Penna TC (1992) Thermal resistance of spores of Bacillus stearothermophilus ATCC 7953 on preparations. Effect of calcium ions on the performance of biological indicators. Associate Professor thesis, Pharmaceutical Sciences School of São Paulo University Brasil, p 22–55

    Google Scholar 

  • Young JH, Ferko BL, Garber RP (1994) Parameters governing steam sterilization of dead legs. J Pharm Sci Technol 48: 140–147

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Vessoni Penna, T.C., Machoshvili, I.A. & Aquarone, E. Bacillus stearothermophilus spores on strips. Calibration of thermoresistance kinetics to prior biological validation. Appl Microbiol Biotechnol 46, 340–346 (1996). https://doi.org/10.1007/BF00166227

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00166227

Keywords

Navigation