Title: The effect of 50/60 Hz notch filter application on human and rat ECG recordings
Source:

Physiological Measurement [0967-3334] Vale Cardoso, A S yr:2009


Collapse list of basic services Basic
Full text
Full text available via Institute of Physics Historic Archive Purchase
GO
Document delivery
Request document via Library/Bibliothek GO
Users interested in this article also expressed an interest in the following:
1. Kligfield, P. "Prevalence and clinical implications of improper filter settings in routine electrocardiography." The American journal of cardiology 99.5 (2007): 711-3. Link to SFX for this item
2. Dobrev, D. "Two-electrode low supply voltage electrocardiogram signal amplifier." Medical & biological engineering & computing 42.2 (2004): 272-6. Link to SFX for this item
3. Huhta, J C C. "60-HZ interference in electrocardiography." IEEE transactions on bio-medical engineering 20.2 (1973): 91-101. Link to SFX for this item
4. Coleman, M. "A technician's guide for basic ECG analysis. Technical suggestions for reducing baseline artifact in ECG recordings." Journal of electrocardiology 40.1 (2007): 63-64. Link to SFX for this item
5. Giuliano, Karen K K. "What is inside the electrocardiograph?" Journal of Electrocardiology 41.1 (2008): 8-14. Link to SFX for this item
6. Johnston, P. "A review of electrocardiogram filtering." Journal of electrocardiology 2010. 486-496. Link to SFX for this item
7. Shaw, C. "Electrocardiography Pitfalls and Artifacts: The 10 Commandments." Critical Care Nurse 29.1 (2009): 67-73. Link to Full Text for this item Link to SFX for this item
8. Garca-Niebla, J. "Effects of inadequate low-pass filter application." Journal of Electrocardiology 42.4 (2009): 303-4. Link to SFX for this item
9. Burri, H. "Simulation of anteroseptal myocardial infarction by electrocardiographic filters." Journal of Electrocardiology 39.3 (2006): 253-8. Link to SFX for this item
10. Mudrov, N. "Simple two-electrode biosignal amplifier." Medical & biological engineering & computing 43.6 (2005): 725-30. Link to SFX for this item
11. Kishto, O. "ECG electrode positioning - luck or judgment?" Heart 102.12 (2016). Link to SFX for this item
12. Levkov, C. "Removal of power-line interference from the ECG: A review of the subtraction procedure." Biomedical engineering online 4.1 (2005): 18-18. Link to Full Text for this item Link to SFX for this item
13. Towe, B C C. "Comments on "ground-free ECG recording with two electrodes"." IEEE transactions on bio-medical engineering BME-28.12: 838-839. Link to SFX for this item
14. Rijnbeek, P R R. "Minimum bandwidth requirements for recording of pediatric electrocardiograms." Circulation 104.25 (2002): 3087-90. Link to SFX for this item
15. Chimene, MF. "A comprehensive model for power line interference in biopotentialmeasurements." IEEE transactions on instrumentation and measurement 49.3 (2000): 535-540. Link to SFX for this item
16. Spinelli, Enrique Mario, E. "AC-Coupled Front-End for Biopotential Measurements." IEEE transactions on bio-medical engineering 50.3 (2003): 391-395. Link to SFX for this item
17. Henning Høyte, Torstein Jensen and Knut Gjesd, K. "Cardiac auscultation training of medical students: a comparison of electronic sensor-based and acoustic stethoscopes." BMC medical education 5.1 (2005): 14-14. Link to Full Text for this item Link to SFX for this item
18. Burke, MJ J. "A micropower dry-electrode ECG preamplifier." IEEE transactions on bio-medical engineering 47.2 (2000): 155-162. Link to SFX for this item
19. Ayachi, M. "A novel fully integrated device dedicated to ECG signal measurement." Analog integrated circuits and signal processing 52.1 (2007): 1-10. Link to SFX for this item