Cadmium-Its in vivo detection in man

, , and

Published under licence by IOP Publishing Ltd
, , Citation J S McLellan et al 1975 Phys. Med. Biol. 20 88 DOI 10.1088/0031-9155/20/1/008

0031-9155/20/1/88

Abstract

Neutron capture gamma -ray analysis has been applied to the in vivo detection of Cd in man. The technique was designed for the screening of industrial workers at risk. The limit of sensitivity in a liver-sized phantom is 0.5 ppm for a dose of 0.4 rad. Reproducibility and the effects of positional uncertainties have been investigated. A number of cadavers were studied to establish normal limits prior to commencement of a programme of clinical investigation. A patient with known Cd poisoning was estimated to contain 65-110 ppm of Cd in his liver. A liver dose of 0.05 rad was required.

Export citation and abstract BibTeX RIS

10.1088/0031-9155/20/1/008