Zusammenfassung
Das Treibmittel wird durch Ausfrieren abgetrennt und die Insecticidlösung gas-chromatographisch mit Electron-capture Detektor analysiert. Das reine α-Isomere dient als innerer Standard. Der Fehler beträgt ± 5%.
Summary
A method was developed for the determination of the lindane content of commercial household insecticide spray aerosols. After the propellant is removed from the chilled contents of the spray packages the hydrocarbon solution is analysed for its lindane content by electron-capture gas chromatography. Pure α-isomer of hexachlorocyclohexane serves as the internal standard. Experimental error is ± 5%.
References
De Vos, R. H., Bosma, M. P. M. M., Brouwer, A. E.: J. Chromatogr. 93, 91 (1974)
Fieser, L., Fieser, M.: Advanced organic chemistry, p. 786. New York: Rheinhold 1961
Horwitz, W. (edit.): Official methods of analysis of the AOAC, p. 534 (1975)
Junk, G. A.: J. Chromatogr. 99, 145 (1974)
Palmer, L., Kalmodin-Hedman, B.: J. Chromatogr. 74, 21 (1972)
Safe, S., Hutzinger, O.: Organic Mass Spec. 1, 217 (1973)
Safe, S., Hutzinger, O. (edit.): Mass spec. of pesticides and pollutants, pp. 131–133. C.R.C. Press (1973)
Shatkay, A.: Anal. Chem. 50, 1423 (1978)
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Vincze, A., Gefen, L., Fisher, A. et al. Gas-chromatographic quantitation of lindane in household insecticide spray cans. Z. Anal. Chem. 305, 193–195 (1981). https://doi.org/10.1007/BF00492614