Summary

Water can be determined directly in organic solvents in the ng range after separation on a porapak-QS column using a linear electron-capture detector (ECD). Organic solvents can be dried by activated 4 Å molecular sieves to a water content of 5 μg/ml, about 0.3×10−3 molar. To exclude water contamination all operations, storage of solvents and standards included, were made in a glove box with permanent drying of the inside atmosphere. The EC-detector allows to determine 15 ng of water absolute. In the range of 7–150 μg/ml a linear response for water by the ECD has been found.

Zusammenfassung

Wasser ist in organischen Lösungsmitteln im ng-Bereich gas-chromatographisch ohne Derivatisierung mittels eines linearisierten Elektroneneinfangdetektors (ECD) nach Abtrennung auf einer Porapak QS-Säule bestimmbar. Ausreichend wasserfreie Lösungsmittel ließen sich durch Trocknen mit aktivierten 4 Å-Molekularsieben oder superaktiven Aluminiumoxiden W 200, Woelm Pharma, Eschwege, herstellen. Um Wasserblindwerte aus der Raumluft auszuschließen, ist es notwendig, sämtliche Operationen in einer Box mit Umlauftrocknung durchzuführen. Wassermengen bis zu 15 ng absolut sind bestimmbar. Im Konzentrationsbereich 7–150 μg/ml ist die Detektoranzeige für Wasser linear.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

Literatur

  1. Ballschmiter, K., Cotton, T. M., Strain, H. H., Katz, J. J.: Biochim. Biophys. Acta180, 347 (1969)

    Google Scholar 

  2. Barbetta, A., Edgell, W.: Appl. Spectroscopy32 (1), 93 (1978)

    Google Scholar 

  3. Bellobono, J. R.: Anal. Chem.39, 1299 (1967)

    Google Scholar 

  4. Castello, G., Munari, S.: J. Chromatogr.31, 202 (1967)

    Google Scholar 

  5. Cotton, T. M., Ballschmiter, K., Katz, J. J.: J. Chromatogr. Sci.8, 546 (1970)

    Google Scholar 

  6. Hogan, J. M., Engel, R. A., Stevenson, H. F.: Anal. Chem.42, 249 (1970)

    Google Scholar 

  7. Hoyt, J. L.: Anal. Chim. Acta44, 369 (1969)

    Google Scholar 

  8. Janick, A.: J. Chromatogr. Sci.13, 93 (1975)

    Google Scholar 

  9. Kaiser, R.: Chromatographia2, 453 (1969)

    Google Scholar 

  10. Kaiser, R.: Chromatographia3, 38 (1970)

    Google Scholar 

  11. Lovelock, J. E., Watson, A. J.: J. Chromatogr.158, 123 (1978)

    Google Scholar 

  12. Mitchell, J., Smith, D. M.: Chemical analysis, Vol. 5, Aquametrie: A treatise on methods for the determination of water; sec. ed. New York: J. Wiley Inc. 1977

    Google Scholar 

  13. Roddy, J. W., Coleman, C. F.: Talanta15, 1281 (1968)

    Google Scholar 

  14. Sakano, T., Hori, Y., Tomari, Y.: J. Chromatogr. Sci.14, 501 (1976)

    Google Scholar 

  15. Schupp, R. L., Mecke, R.: Z. Elektrochem.52, 54 (1948)

    Google Scholar 

  16. Sellers, P.: Acta Chem. Scand.25, 2295 (1971)

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Scholz, B., Ballschmiter, K. Gas-chromatographische Bestimmung von Wasser mit dem Elektronen-Einfang-Detektor im Nanogramm-Bereich. Z. Anal. Chem. 302, 264–268 (1980). https://doi.org/10.1007/BF00694508

Download citation

  • Received:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00694508

Key words

Navigation