Skip to main content
Log in

A clinical system for accurate assessment of tissue iron concentration

  • Published:
Il Nuovo Cimento D

Summary

This paper describes a new computer-enhanced dual-channel SQUID susceptometer designed to achieve accuratein vivo estimates of tissue storage iron concentrations. We discuss the practical design considerations, instrumental noise performance and anticipated clinical resolution of the new system.

Riassunto

Questo lavoro descrive un nuovo suscettometro SQUID a doppio canale coadiuvato da computer destinato a raggiungere stime accuratein vivo delle concentrazioni di accumulo di ferro nei tessuti. Si discutono le considerazioni pratiche dello schema, la funzionalità sperimentale al rumore e la risoluzione clinica anticipata del nuovo sistema.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. J. W. Harris, D. E. Farrell andM. J. Messer:Clin. Res. A,26 504 (1978).

    Google Scholar 

  2. D. E. Farrell, J. H. Tripp, P. E. Zanzucchi, J. W. Harris, G. M. Brittenham andW. A. Muir:IEEE Trans. Magn., MAG-16, 818 (1980).

    Article  ADS  Google Scholar 

  3. D. E. Farrell, J. H. Tripp, P. E. Zanzucchi, J. W. Harris, G. M. Brittenham andW. A. Muir:Biomagnetism, (Berlin, 1981), p. 507.

  4. D. E. Farrell, J. H. Tripp, P. E. Zanzucchi, J. W. Harris, G. M. Brittenham, W. A. Muir andE. M. Bellon:Appl. Phys. Commun.,1, 1 (1981).

    Google Scholar 

  5. G. M. Brittenham, D. E. Farrell, J. W. Harris, E. S. Feldman, E. H. Danish, W. A. Muir, J. H. Tripp, J. N. Brennan andE. M. Bellon:N. Engl. J. Med.,307, 1671 (1982).

    Article  Google Scholar 

  6. E. Weber:Electromagnetic Theory (New York, N. Y., 1965), p. 140.

  7. C. M. Bastuscheck, D. Brenner, S. J. Williamson andL. Kaufman:Biomagnetism (Berlin, 1981), p. 519.

  8. D. E. Farrell andP. Zanzucchi:Crit. Rev. Solid State Sci. (in press).

Download references

Author information

Authors and Affiliations

Authors

Additional information

Work supported by NIH grants HL24198 and AM25105.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Farrell, D.E., Tripp, J.H., Brittenham, G.M. et al. A clinical system for accurate assessment of tissue iron concentration. Il Nuovo Cimento D 2, 582–593 (1983). https://doi.org/10.1007/BF02455956

Download citation

  • Received:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02455956

PACS. 87.40

PACS. 85.25

Navigation