Please use this identifier to cite or link to this item: https://hdl.handle.net/11681/9529
Title: Water absorption of insulation in protected membrane roofing systems
Authors: Schaefer, David
Keywords: Cold weather construction
Cold regions
Insulation
Roofing
Roofs
Publisher: Cold Regions Research and Engineering Laboratory (U.S.)
Engineer Research and Development Center (U.S.)
Series/Report no.: CRREL report ; 76-38.
Description: CRREL Report
Abstract: Current methods for evaluation of the moisture absorption of plastic insulations (ASTM-C-272-53 and ASTM-C-355-64) due to vapor pressure gradients or immersion rely on short time periods to predict long term performance. This procedure may not provide accurate information on performance since in practice insulations may absorb more moisture than these tests indicate. A series of tests were conducted on extruded polystyrene roof insulation that had been in place, exposed to environmental moisture and pressure gradients, for a maximum of 36 months. Results indicate that moisture absorption of 1.5% by volume can be expected in the field.
Rights: Approved for public release; distribution is unlimited.
URI: http://hdl.handle.net/11681/9529
Appears in Collections:CRREL Report

Files in This Item:
File Description SizeFormat 
CR-76-38.pdf3.31 MBAdobe PDFThumbnail