Publication Date:
2019-06-27
Description:
The three-dimensional nozzle admittance, an important parameter in combustion instability studies, was experimentally measured for several nozzle configurations. The admittance values were obtained using a modification of the classical impedance tube technique. The modified impedance tube method measures the admittance of a duct termination in the presence of one-dimensional mean flow and three-dimensional oscillations. Values of the nozzle admittance were obtained from pressure amplitude measurements taken at discrete points along the length of the tube. To determine the effects of nozzle geometry, nozzles were tested with half-angles of 15, 30, and 45 deg and entrance Mach numbers of 0.08, 0.16, and 0.20. The admittance results are presented as functions of nondimensional frequency for mixed first tangential-longitudinal modes. These results are compared with available theoretical predictions, and good agreement between theory and experiment is shown.
Keywords:
THERMODYNAMICS AND COMBUSTION
Type:
AIAA Journal; 11; Mar. 197
Format:
text
Permalink