ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
Filter
  • METEOROLOGY AND CLIMATOLOGY  (430)
  • INSTRUMENTATION AND PHOTOGRAPHY  (270)
  • 1980-1984  (700)
  • 1935-1939
Sammlung
Erscheinungszeitraum
Jahr
  • 1
    Publikationsdatum: 2019-07-27
    Beschreibung: An experimental version of a thinned illuminated buried-channel 512 x 320 pixel CCD with reduced amplifier input capacitance has been produced which is characterized by lower readout noise. Changes made to the amplifier are discussed, and readout noise measurements obtained by several different techniques are presented. The single energetic electron response of the CCD in the electron-bombarded mode and the single 5.9 keV X-ray pulse height distribution are reported. Results are also given on the dark current versus temperature and the spatial frequency response as a function of signal level.
    Schlagwort(e): INSTRUMENTATION AND PHOTOGRAPHY
    Materialart: Solid state imagers for astronomy; June 10, 11, 1981; Cambridge, MA
    Format: text
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    Publikationsdatum: 2011-08-19
    Schlagwort(e): INSTRUMENTATION AND PHOTOGRAPHY
    Materialart: NASA, Washington Upper Atmosphere Res. Program; p 234-235
    Format: text
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 3
    facet.materialart.
    Unbekannt
    In:  Other Sources
    Publikationsdatum: 2011-08-18
    Beschreibung: A dark spiral feature is noted in the geosynchronous satellite visible image of the top of a thunderstorm which also has a Doppler radar-observed mesocyclone. Although the evidence is not conclusive, the feature may represent cyclonic rotation at cloud top associated with the pre-tornado mesocyclone.
    Schlagwort(e): METEOROLOGY AND CLIMATOLOGY
    Materialart: Monthly Weather Review; 109; May 1981
    Format: text
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 4
    Publikationsdatum: 2011-08-18
    Beschreibung: A diode-laser-based, ultrahigh resolution IR heterodyne spectrometer for laboratory and field use has been developed for operation between 7.5 and 8.5 microns. The local oscillator is a PbSe tunable diode laser kept continuously at operating temperatures of 12-60 K using a closed-cycle cooler. The laser output frequency is controlled and stabilized using a high-precision diode current supply, constant temperature controller, and a shock isolator mounted between the refrigerator cold tip and the diode mount. The system largely employs reflecting optics to minimize losses from internal reflection and absorption and to eliminate chromatic effects. Spectral analysis of the diode-laser output between 0 and 1 GHz reveals excess noise at many diode current settings, which limits the IR spectral regions over which useful heterodyne operation can be achieved. Observations have been made of atmospheric N2O, O3, and CH4 between 1170 and 1200/cm, using both a single-frequency swept IF channel and a 64-channel RF spectral line receiver with a total IF coverage of 1600 MHz.
    Schlagwort(e): INSTRUMENTATION AND PHOTOGRAPHY
    Materialart: Applied Optics; 21; Jan. 15
    Format: text
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 5
    Publikationsdatum: 2011-08-19
    Beschreibung: Attention is given to 1.2 years of data from two Michelson-Gale long fluid tiltmeters, one long center pressure tiltmeter, and a shallow borehole tiltmeter, which have been in operation at Pinon Flat Observatory in Southern California. The most stable tilt record shows a secular rate of 0.28 microrad/a, which may be real. Comparisons undertaken among instruments have identified more and less successful measurement techniques. It is concluded that even the best existing sensors must be improved in order to measure continuous tectonic motions.
    Schlagwort(e): INSTRUMENTATION AND PHOTOGRAPHY
    Materialart: Geophysical Research Letters (ISSN 0094-8276); 11; 963-966
    Format: text
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 6
    Publikationsdatum: 2016-06-07
    Beschreibung: A redesign of the antenna electronics package for the NBS/GPS C/A receiver has resulted in significantly reduced cost and improved performance. Major improvements include a simplified and more reliable multiplier/mixer, elimination of all twelve piston trimmer tuning capacitors in the original design, elimination of expensive bandpass filters, less expensive antenna and a simplified packaging scheme.
    Schlagwort(e): INSTRUMENTATION AND PHOTOGRAPHY
    Materialart: NASA. Goddard Space Flight Center Proc. of the 16th Ann. Precise Time and Time Interval (PTTI) Appl. and Planning Meeting; p 467-474
    Format: application/pdf
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 7
    Publikationsdatum: 2019-06-27
    Beschreibung: The results of numerical models or of new observational programs are checked by comparing them with past observations. In view of the differing analysis techniques or differing data samples, the eddy diffusivities presented here agree remarkably well with past estimates. However, in the application of K-values to two-dimensional models, the actual magnitude of the diffusivities is no more important than their spatial patterns, i.e., their gradients with height and latitude. It should thus be noted that the present patterns are often much different from those of past results.
    Schlagwort(e): METEOROLOGY AND CLIMATOLOGY
    Materialart: Pure and Applied Geophysics; 118; 5, 19; 1980
    Format: text
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 8
    Publikationsdatum: 2019-06-28
    Beschreibung: Raw data from the Solar Backscattered Ultrviolet/Total Ozone Mapping Spectrometer (SBUV/TOMS) Nimbus 7 operation are available on computer tape. These data are contained on two separate sets of RUTs (Raw Units Tapes) for SBUV and TOMS, labelled RUT-S and RUT-T respectively. The RUT-S and RUT-T tapes contain uncalibrated radiance and irradiance data, housekeeping data, wavelength and electronic calibration data, instrument field-of-view location and solar ephemeris information. These tapes also contain colocated cloud, terrain pressure and snow/ice thickness data, each derived from an independent source. The "RUT User's Guide" describes the SBUV and TOMS experiments, the instrument calibration and performance, operating schedules, and data coverage, and provides an assessment of RUT-S and -T data quality. It also provides detailed information on the data available on the computer tapes.
    Schlagwort(e): METEOROLOGY AND CLIMATOLOGY
    Materialart: NASA-RP-1112 , REPT-910 , NAS 1.61:1112
    Format: application/pdf
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 9
    Publikationsdatum: 2019-07-27
    Beschreibung: A soft X-ray/XUV imaging camera which uses a thinned, back-illuminated, all-buried channel RCA CCD for radiation sensing has been built and tested. The camera is a slow-scan device which makes possible frame integration if necessary. The detection characteristics of the device have been tested over the 15-1500 eV range. The response was linear with exposure up to 0.2-0.4 erg/sq cm; saturation occurred at greater exposures. Attention is given to attempts to resolve single photons with energies of 1.5 keV.
    Schlagwort(e): INSTRUMENTATION AND PHOTOGRAPHY
    Materialart: Solid state imagers for astronomy; June 10, 11, 1981; Cambridge, MA
    Format: text
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 10
    Publikationsdatum: 2019-07-27
    Beschreibung: The employment of area focal plane arrays (FPA) has made it possible to obtain second generation infrared imaging systems with high resolution and sensitivity. The Short Wavelength Infrared (SWIR) region (1-2.5 microns) is of importance for imaging objects at high temperature and under conditions of reflected sunlight. The present investigation is concerned with electrooptical characterization results for 32 x 32 SWIR detector arrays and FPAs which are suitable for use in a prototype imaging spectrometer. The employed detector material is Hg(1-x)Cd(x)Te grown by liquid phase epitaxy on a CdTe transparent substrate. Attention is given to details of processing, the design of the detector array, the multiplexer, the fabrication of the hybrid FPA, and aspects of performance.
    Schlagwort(e): INSTRUMENTATION AND PHOTOGRAPHY
    Materialart: Technical issues in infrared detectors and arrays; April 5, 6, 1983; Arlington, VA
    Format: text
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...