ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Life and Medical Sciences  (339)
  • SOLAR PHYSICS  (324)
  • INSTRUMENTATION AND PHOTOGRAPHY  (270)
  • 1980-1984  (894)
  • 1940-1944  (39)
Collection
Publisher
Years
Year
  • 11
    Publication Date: 2016-06-07
    Description: A redesign of the antenna electronics package for the NBS/GPS C/A receiver has resulted in significantly reduced cost and improved performance. Major improvements include a simplified and more reliable multiplier/mixer, elimination of all twelve piston trimmer tuning capacitors in the original design, elimination of expensive bandpass filters, less expensive antenna and a simplified packaging scheme.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA. Goddard Space Flight Center Proc. of the 16th Ann. Precise Time and Time Interval (PTTI) Appl. and Planning Meeting; p 467-474
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 12
    Publication Date: 2019-06-28
    Description: Absorption features from the 8 micron SiO fundamental (upsilon = 1-0) and hot bands (upsilon = 2-1) have been observed in sunspots at sub-Doppler resolution using a ground-based tunable diode laser heterodyne spectrometer. The observed line widths suggest an upper limit of 0.5 km/s for the microturbulent velocity in sunspot umbrae. Since the silicon monoxide abundance is very sensitive to sunspot temperature, the measured equivalent widths permit an unambiguous determination of the temperature-pressure relation in the upper layers of the umbral atmosphere. In the region of SiO line formation (log P sub g = 3.0-4.5), the results support the sunspot model suggested by Stellmacher and Wiehr (1970).
    Keywords: SOLAR PHYSICS
    Type: Astrophysical Journal, Part 1 (ISSN 0004-637X); 269; June 1
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 13
    Publication Date: 2019-07-27
    Description: A soft X-ray/XUV imaging camera which uses a thinned, back-illuminated, all-buried channel RCA CCD for radiation sensing has been built and tested. The camera is a slow-scan device which makes possible frame integration if necessary. The detection characteristics of the device have been tested over the 15-1500 eV range. The response was linear with exposure up to 0.2-0.4 erg/sq cm; saturation occurred at greater exposures. Attention is given to attempts to resolve single photons with energies of 1.5 keV.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Solid state imagers for astronomy; June 10, 11, 1981; Cambridge, MA
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 14
    Publication Date: 2019-07-27
    Description: The employment of area focal plane arrays (FPA) has made it possible to obtain second generation infrared imaging systems with high resolution and sensitivity. The Short Wavelength Infrared (SWIR) region (1-2.5 microns) is of importance for imaging objects at high temperature and under conditions of reflected sunlight. The present investigation is concerned with electrooptical characterization results for 32 x 32 SWIR detector arrays and FPAs which are suitable for use in a prototype imaging spectrometer. The employed detector material is Hg(1-x)Cd(x)Te grown by liquid phase epitaxy on a CdTe transparent substrate. Attention is given to details of processing, the design of the detector array, the multiplexer, the fabrication of the hybrid FPA, and aspects of performance.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Technical issues in infrared detectors and arrays; April 5, 6, 1983; Arlington, VA
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 15
    Publication Date: 2019-07-13
    Description: Infrared heterodyne spectroscopy is a passive technique employing coherent optical detection for the study of spectral features in remote sources. It employs optical components such as mirrors and lenses normally associated with incoherent optics, but because of it's coherent nature, it offers the advantages of ultrahigh spectral resolving power, high frequency precision, and diffraction limited field-of-view. Attention is given to the development of an ultrahigh resolution diode laser heterodyne spectrometer for observational and laboratory use. The instrument is designed for operation in the spectral range from 7.5 to 8.5 microns. A PbSe tuneable diode laser (TDL) is employed as local oscillator. A closed-cycle cooler is employed to keep the oscillator at operating temperatures in the range from 12 to 60 K. Attention is given to factors determining the TDL heterodyne sensitivity, the spectrometer design, and a survey of 8 micron observations, SiO could be detected in the sunspot spectrum.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Instrumentation in astronomy IV; Fourth Conference; Mar 08, 1982 - Mar 10, 1982; Tucson, AZ
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 16
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Cell Motility and the Cytoskeleton 1 (1980), S. 63-71 
    ISSN: 0886-1544
    Keywords: Physarum polycephalum ; myosin light chains ; polyacrylamide gel electrophoresis ; calcium ; cytoplasmic streaming ; actomyosin ATPase regulation ; Life and Medical Sciences ; Cell & Developmental Biology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Medicine
    Notes: Myosin from the slime mold Physarum polycephalum contains three sizes of polypeptides: a heavy chain and two light chains, LC-1 and LC-2. Using a simple qualitative test for calcium binding by comparing electrophoretic migration of the polypeptides in sodium dodecy1 sulfate (SDS) acrylamide gels in the presence and absence of calcium, we have found that Physarum myosin light chain LC-2 migrates with an apparent molecular weight of 16,900 daltons in the presence of the metal ion chelator ethylene glycol bis (B-aminoethyl ether) N,N′-tetraacetic acid (EGTA). However, if calcium chloride is added to the sample prior to electrophoresis, the apparent molecular weight decreases to 16,100. Lanthanide and cadmium ions, but not magnesium, can substitute for calcium. Because the ionic radii of Ca2+, La3+, and Cd2+ are almost identical, we conclude that Physarum myosin LC-2 possesses a very size-specific binding site for calcium. Physarum myosin LC-1 and the heavy chain give no evidence for binding calcium by this test. Since cytoplasmic streaming in the plasmodium of Physarum requires calcium, our evidence indicates that the calcium-binding property of Physarum myosin LC-2 may be important in regulating the production of force by actomyosin in the ectoplasm. Unexpectedly, the myosin light chain in Physarum capable of binding calcium, LC-2, is the essential light chain, while LC-1 is a member of the regulatory class of myosin light chains [V. T. Nachmias, personal communication]. Until now, essential myosin light chains have not been shown to have high affinity divalent cation binding sites. This means a new version of the myosin-based model for actomyosin regulation by calcium may be required to explain cytoplasmic movement in Physarum, and perhaps in other motile systems involving cytoplasmic myosins as well.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 17
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Cell Motility and the Cytoskeleton 3 (1983), S. 1-19 
    ISSN: 0886-1544
    Keywords: cytoplasmic transport ; Saltation ; microtubules ; keratocytes ; Life and Medical Sciences ; Cell & Developmental Biology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Medicine
    Notes: We report the first direct demonstration that the cytoplasmic transport of organelles and vesicles (collectively called particles) takes place along microtubules. Living keratocytes from the corneal stroma of the frog, Rana pipiens, were observed with Allen video-enhanced constrast, differential interference constrast (AVEC-DIC) microscopy [Allen et al, 1981]. In sufficiently thin regions of these cells a network of linear elements was visible. When particles were observed in motion, they always moved along these linear elements. The linear elements remained intact and in focus on the microscope when lysed in a cell lysis solution that stabilized microtubules. Preparations were then fixed in formaldehyde, washed with phosphate-buffered saline (PBS), incubated with rabbit antitubulin, washed with PBS, stained with rhodamine-conjugated goat antirabbit, and washed with PBS. The extracted cells continued to remain in place and in focus on the microscope throughout these procedures. The same cells were then observed using epifluorescence optics and a silicon-intensified target (SIT) video camera. A network of fluorescent linear elements was seen to correspond in number, form, and position to the linear elements seen in the live AVEC-DIC image. Taken together, the AVEC-DIC and fluorescence microscopy observations prove that the linear elements along which particles move are microtubules (MTLEs). The observed particle speeds, pause times, and distances moved varied widely, even for the same particle on the same microtubule. Particles were also observed to switch from one microtubule to another as they were transported. The polarity of the microtubules did not seem to affect the particle direction, since particles were observed to move in both directions on the same MTLE. When not in motion these particles behaved as if anchored to the microtubules since they showed negligible Brownian motion. Finally, it was observed that an elongate particle could move onto two intersecting linear elements such that it was deformed into an inverted “Y” shape. This indicates that there may be more than a single site of attachment between the force generator and the particle.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 18
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Cell Motility and the Cytoskeleton 1 (1980), S. 159-162 
    ISSN: 0886-1544
    Keywords: Life and Medical Sciences ; Cell & Developmental Biology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Medicine
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 19
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Cell Motility and the Cytoskeleton 2 (1982), S. 113-119 
    ISSN: 0886-1544
    Keywords: Life and Medical Sciences ; Cell & Developmental Biology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Medicine
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 20
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 1 (1980), S. 131-147 
    ISSN: 0197-8462
    Keywords: electric fields ; rat ; sciatic nerve ; vagus nerve ; superior cervical sympathetic ganglion ; chronic exposure ; 60 Hz ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: Several reports have suggested that the nervous system can be affected by exposure to electric fields and that these effects may have detrimental health consequences for the exposed organism. The purpose of this study was to investigate the effects of chronic (30-day) exposure of rats to a 60-Hz, 100-kV/m electric field on synaptic transmission and peripheral-nerve function. One hundred forty-four rats, housed in individual polycarbonate cages were exposed to uniform, vertical, 60-Hz electric fields in a system free of corona discharge and ozone formation and in which the animals did not receive spark discharges or other shocks during exposure. Following 30 days of exposure to the electric field, superior cervical sympathetic ganglia, vagus and sciatic nerves were removed from rats anesthetized with urethan, placed in a temperature-controlled chamber, and superfused with a modified mammalian Ringer's solution equilibrated with 95% O2 and 5% CO2. Several measures and tests were used to characterize synaptic transmission and peripheral-nerve function. These included amplitude, area, and configuration of the postsynaptic or whole-nerve compound-action potential; conduction velocity; accommodation; refractory period; strength-duration curves; conditioning-test (C-T) response, frequency response; post-tetanic response; and high-frequency-induced fatigue. The results of a series of neurophysiologic tests and measurements indicate that only synaptic transmission is significantly and consistently affected by chronic (30-day) exposure to a 60-Hz, 100-kV/m electric field. Specifically, an increase in synaptic excitability was detected in replicated measurements of the C-T response ratio. In addition, there are trends in other data that can be interpreted to suggest a generalized increase in neuronal excitability in exposed animals.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...